<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>http://online.spectraqest.com/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=John.meegan</id>
	<title>QESTonline - User contributions [en]</title>
	<link rel="self" type="application/atom+xml" href="http://online.spectraqest.com/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=John.meegan"/>
	<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php/Special:Contributions/John.meegan"/>
	<updated>2026-04-07T13:05:58Z</updated>
	<subtitle>User contributions</subtitle>
	<generator>MediaWiki 1.43.6</generator>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=Template:QEST_Platform_4.5.2979&amp;diff=31415</id>
		<title>Template:QEST Platform 4.5.2979</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=Template:QEST_Platform_4.5.2979&amp;diff=31415"/>
		<updated>2018-02-27T00:22:31Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==QEST Platform 4.5.2979==&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
!Issue ID&lt;br /&gt;
!Release Notes&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1706&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Problems with QESTField&#039;s concrete docket import going slowly have been fixed. This should prevent SQL timeout errors provided timeouts are set to reasonable values.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1708&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Creating charges for billing was not using the &amp;quot;Maximum Units&amp;quot; feature of Billable Items. This was leading to all units being charged. Charging will now stop at the maximum units, or use the &amp;quot;Additional Item Code&amp;quot; to find a second fee schedule to charge remaining items with. Note that the QEST Administrator Option &amp;quot;Alternative Billing Process&amp;quot; needs to be set to &amp;quot;False&amp;quot; for this functionality to work.&lt;br /&gt;
&lt;br /&gt;
Fee schedules that had a blank &amp;quot;Default&amp;quot; field were being ignored. They are now loaded if there are no fee schedules with &amp;quot;Default&amp;quot; set to &amp;quot;Yes&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1715&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QESTLab and QESTField have been changed so that when the Date Batched is imported from a docket and Date Cast is not yet set, the Date Cast will be set to the Date Batched.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1719&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed bugs for the Masonry Sample (ID 1605) preventing the proper import, saving and loading of Required Strength and Required Net Strength values. Prevented some Concrete Sample values from being cleared from the bulk entry in the case where a Concrete Mix had not been selected for the sample.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1722&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an Error 13: Type Mismatch that could occur when using the Auto Create button for a Billing document.&lt;br /&gt;
&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=QEST_Platform_4.5.2979&amp;diff=31413</id>
		<title>QEST Platform 4.5.2979</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=QEST_Platform_4.5.2979&amp;diff=31413"/>
		<updated>2018-02-27T00:20:43Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==QEST Platform 4.5.2979==&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
!Issue ID&lt;br /&gt;
!Release Notes&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1706&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Problems with QESTField&#039;s concrete docket import going slowly have been fixed. This should prevent SQL timeout errors provided timeouts are set to reasonable values.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1708&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Creating charges for billing was not using the &amp;quot;Maximum Units&amp;quot; feature of Billable Items. This was leading to all units being charged. Charging will now stop at the maximum units, or use the &amp;quot;Additional Item Code&amp;quot; to find a second fee schedule to charge remaining items with. Note that the QEST Administrator Option &amp;quot;Alternative Billing Process&amp;quot; needs to be set to &amp;quot;False&amp;quot; for this functionality to work.&lt;br /&gt;
&lt;br /&gt;
Fee schedules that had a blank &amp;quot;Default&amp;quot; field were being ignored. They are now loaded if there are no fee schedules with &amp;quot;Default&amp;quot; set to &amp;quot;Yes&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1715&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QESTLab and QESTField have been changed so that when the Date Batched is imported from a docket and Date Cast is not yet set, the Date Cast will be set to the Date Batched.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1719&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed bugs for the Masonry Sample (ID 1605) preventing the proper import, saving and loading of Required Strength and Required Net Strength values. Prevented some Concrete Sample values from being cleared from the bulk entry in the case where a Concrete Mix had not been selected for the sample.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1722&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an Error 13: Type Mismatch that could occur when using the Auto Create button for a Billing document.&lt;br /&gt;
&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=Template:QEST_Platform_4.6.2974&amp;diff=31409</id>
		<title>Template:QEST Platform 4.6.2974</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=Template:QEST_Platform_4.6.2974&amp;diff=31409"/>
		<updated>2018-02-22T05:34:47Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=QEST_Platform_4.6.2974&amp;diff=31407</id>
		<title>QEST Platform 4.6.2974</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=QEST_Platform_4.6.2974&amp;diff=31407"/>
		<updated>2018-02-22T05:33:54Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=Template:QEST_Platform_4.6.2974&amp;diff=31406</id>
		<title>Template:QEST Platform 4.6.2974</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=Template:QEST_Platform_4.6.2974&amp;diff=31406"/>
		<updated>2018-02-22T04:42:34Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==QEST Platform 4.6.2974==&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
!Issue ID&lt;br /&gt;
!Release Notes&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1706&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Problems with QESTField&#039;s concrete docket import going slowly have been fixed. This should prevent SQL timeout errors provided timeouts are set to reasonable values.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1715&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QESTLab and QESTField have been changed so that when the Date Batched is imported from a docket and Date Cast is not yet set, the Date Cast will be set to the Date Batched.&lt;br /&gt;
&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=QEST_Platform_4.6.2974&amp;diff=31401</id>
		<title>QEST Platform 4.6.2974</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=QEST_Platform_4.6.2974&amp;diff=31401"/>
		<updated>2018-02-22T04:40:51Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==QEST Platform 4.6.2974==&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
!Issue ID&lt;br /&gt;
!Release Notes&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1706&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Problems with QESTField&#039;s concrete docket import going slowly have been fixed. This should prevent SQL timeout errors provided timeouts are set to reasonable values.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1715&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QESTLab and QESTField have been changed so that when the Date Batched is imported from a docket and Date Cast is not yet set, the Date Cast will be set to the Date Batched.&lt;br /&gt;
&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=Template:QEST_Platform_4.5.2971&amp;diff=31398</id>
		<title>Template:QEST Platform 4.5.2971</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=Template:QEST_Platform_4.5.2971&amp;diff=31398"/>
		<updated>2018-02-19T07:25:22Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==QEST Platform 4.5.2971==&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
!Issue ID&lt;br /&gt;
!Release Notes&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1242&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| In QESTField, the Precision set against the specification is now taken into account when determining whether to style a result, e.g. colouring the text in red, as out of specification.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1243 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made for the entry and display of data in QESTField. Numeric results that have specification limits displayed against them will be formatted according to the Precision set in the specification.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1262 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| For the tests listed below, the equipment used for each test run can now be selected when Weighing Procedure is set to &amp;quot;Water&amp;quot;. Additionally, &amp;quot;Vacuum Flask&amp;quot; can no longer be selected as the Container Type when Weighing Procedure is set to &amp;quot;Water&amp;quot;.&lt;br /&gt;
* Max Specific Gravity and Density of Asphalt (Metric) [ASTM D 2041] (ID 117049)&lt;br /&gt;
* Rice Specific Gravity [ASTM D 2041] (ID 117050)&lt;br /&gt;
* Rice Specific Gravity [AASHTO T 209] (ID 117064)&lt;br /&gt;
* Rice Specific Gravity [NDOT T 324] (ID 117053)&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1265 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed several issues with the display of item status in the QESTLab tree:&lt;br /&gt;
* Items under &amp;quot;Tests/Documents&amp;quot; node will display the same status conditions as they would under the &amp;quot;Work Orders&amp;quot; node&lt;br /&gt;
* Reports which are &amp;quot;Ready to be Signed&amp;quot; will be displayed in blue when first loaded via a filter&lt;br /&gt;
* When loading a filter where items are grouped under multiple fields, combined status conditions will be displayed on every parent group (previously these only displayed on the item&#039;s immediate parent group)&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1271 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| When using the screen for Proctor - Standard [AASHTO T 99 - 2015] the Layers and Blows are now populated based on the selected Method.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1344 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where &amp;quot;Nominal Aggregate Size (mm)&amp;quot; was not saving correctly for US Los Angeles Abrasion Value screens in metric laboratories.&lt;br /&gt;
&lt;br /&gt;
Fixed an issue where &amp;quot;Nominal Aggregate Size (mm)&amp;quot; would not be correctly imported from the Size value of the parent sample&#039;s material in certain circumstances.&lt;br /&gt;
&lt;br /&gt;
Added &amp;quot;Nominal Aggregate Size (mm)&amp;quot; to the reported fields of the following tests, as required by the relevant standards:&lt;br /&gt;
* Los Angeles Abrasion Value [ASTM C 131 - 06] (ID 110160)&lt;br /&gt;
* Los Angeles Abrasion Value [ASTM C 131 - 06]* (ID 110357)&lt;br /&gt;
* LA Abrasion [AASHTO T 96 - 2010] (ID 110164)&lt;br /&gt;
&lt;br /&gt;
The field previously labelled &amp;quot;Test Grading&amp;quot; on the reduced screen Los Angeles Abrasion Value [ASTM C 131 - 06]* (ID 110357) will now be labelled &amp;quot;Grading Designation&amp;quot; to be consistent with the terminology of the standard.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1487 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| For the following tests, where masses are meant to be recorded in grams (g), the labels mistakenly indicated entry in pounds (lb):&lt;br /&gt;
* (ID 110338) Percentage of Fractured Particles in Coarse Aggregate [ASTM D 5821 - 2001]&lt;br /&gt;
* (ID 110343) Percentage of Fractured Particles in Coarse Aggregate [ASTM D 5821 - 2006]&lt;br /&gt;
These captions have been fixed.&lt;br /&gt;
&lt;br /&gt;
The test (ID 110344) Percentage of Fractured Particles in Coarse Aggregate (Imperial) [ASTM D 5821 - 2006], which has Nominal Maximum Size in IP units, has been changed so that by default masses are recorded in grams. A document-level option, &amp;quot;Record masses in lb&amp;quot;, is available for this test if data entry in pounds is still required. When using pounds, the mass can now be entered to the nearest 0.0001 lb.&lt;br /&gt;
&lt;br /&gt;
Masses for all of these tests are always given in grams on the test report.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1492 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug where field &amp;quot;WC Method&amp;quot; was always reported for Relative Compaction [ASTM] (ID 110201). This field will now only report when a moisture content method has been selected on a sibling In-Situ Density - Sand Cone Method [ASTM D 1556 - 2015] (ID 110305) test.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1581&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where the &amp;quot;Days Left on Site&amp;quot; field on the Concrete Sample can overflow and cause QESTField to show an error has been fixed.&lt;br /&gt;
&lt;br /&gt;
Additionally, for both QESTField and QESTLab, when the &amp;quot;Date Cast&amp;quot; is changed while &amp;quot;Days Left on Site&amp;quot; has a value, the &amp;quot;Date Received&amp;quot; will be calculated from these values.&lt;br /&gt;
&lt;br /&gt;
Previously, a shift in the &amp;quot;Date Cast&amp;quot; would produce a shift in the number of curing days (the &amp;quot;Standard Curing Days&amp;quot; field, shown as &amp;quot;Std Cure&amp;quot; in the concrete specimens grid in QESTLab). Now, when the &amp;quot;Date Received&amp;quot; is automatically shifted by the same number of days as the &amp;quot;Test Date&amp;quot;, it will not change the &amp;quot;Standard Curing Days&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1637 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where concrete specimens created via the concrete bulk entry (either by selecting the test group or using a work template) would cause an Error 13 message to appear when loading the Concrete Test Report.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1643 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where adding a Billable Item (ID 20040) without selecting a Test would cause &amp;quot;Invalid Use of Null&amp;quot; errors when adding an entry to the Fee Schedule list (ID 20005).&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1672 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where the PDF Password input for the QEST Administrator Console does not grey out properly has been fixed&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1673 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where an Error 5 message would appear when loading a Concrete Sample bulk entry screen for customers not licensed for the Concrete Mix list (ID 20021)&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1675 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where an Error 91 message could be raised when QESTLab triggered an update when no object was loaded (for example immediately after an object was deleted).&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1676&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where the &amp;quot;Age in Days&amp;quot; (AgeDays) field on the Concrete Specimen can overflow and cause QESTField to show an error has been fixed.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1683&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where the &amp;quot;Days Left On Site&amp;quot; field on the Concrete Specimen was not being updated from the Concrete Sample has been fixed.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1687 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug where results from a sibling grading test were imported over results entered onto Clay Lumps and Friable Particles test screens when &amp;quot;Ignore Grading Results&amp;quot; was checked.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1690 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where attempting to load a Wet/Dry Strength Variation test would raise an Error 13: Type Mismatch message.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1698 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed issue where SQL errors could occur when inserting new Billable Item (ID 20040) list entries.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1701 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug where concrete sample fields could clear for customers not licensed for the Concrete Mix list (ID 20021).&lt;br /&gt;
Fixed a bug where the bulk entry on the work order screen would refresh twice on loading.&lt;br /&gt;
On the work order screen&#039;s sample bulk entry, the Sample Type selection will now be locked when the screen is busy processing another request (eg. changing the number of samples).&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1705 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where Item Name and Charge would be cleared when automatic billing was triggered for manually entered Billing rows, where the associated Billable Item entry was set as editable.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1711 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where the Masonry Report (ID 18958) would show an &amp;quot;Error 91&amp;quot; message on load.&lt;br /&gt;
Fixed an issue where masonry specimens of type MORCUBE could not be reported.&lt;br /&gt;
&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=QEST_Platform_4.5.2971&amp;diff=31397</id>
		<title>QEST Platform 4.5.2971</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=QEST_Platform_4.5.2971&amp;diff=31397"/>
		<updated>2018-02-19T07:25:03Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==QEST Platform 4.5.2971==&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
!Issue ID&lt;br /&gt;
!Release Notes&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1242&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| In QESTField, the Precision set against the specification is now taken into account when determining whether to style a result, e.g. colouring the text in red, as out of specification.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1243 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made for the entry and display of data in QESTField. Numeric results that have specification limits displayed against them will be formatted according to the Precision set in the specification.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1262 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| For the tests listed below, the equipment used for each test run can now be selected when Weighing Procedure is set to &amp;quot;Water&amp;quot;. Additionally, &amp;quot;Vacuum Flask&amp;quot; can no longer be selected as the Container Type when Weighing Procedure is set to &amp;quot;Water&amp;quot;.&lt;br /&gt;
* Max Specific Gravity and Density of Asphalt (Metric) [ASTM D 2041] (ID 117049)&lt;br /&gt;
* Rice Specific Gravity [ASTM D 2041] (ID 117050)&lt;br /&gt;
* Rice Specific Gravity [AASHTO T 209] (ID 117064)&lt;br /&gt;
* Rice Specific Gravity [NDOT T 324] (ID 117053)&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1265 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed several issues with the display of item status in the QESTLab tree:&lt;br /&gt;
* Items under &amp;quot;Tests/Documents&amp;quot; node will display the same status conditions as they would under the &amp;quot;Work Orders&amp;quot; node&lt;br /&gt;
* Reports which are &amp;quot;Ready to be Signed&amp;quot; will be displayed in blue when first loaded via a filter&lt;br /&gt;
* When loading a filter where items are grouped under multiple fields, combined status conditions will be displayed on every parent group (previously these only displayed on the item&#039;s immediate parent group)&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1271 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| When using the screen for Proctor - Standard [AASHTO T 99 - 2015] the Layers and Blows are now populated based on the selected Method.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1344 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where &amp;quot;Nominal Aggregate Size (mm)&amp;quot; was not saving correctly for US Los Angeles Abrasion Value screens in metric laboratories.&lt;br /&gt;
&lt;br /&gt;
Fixed an issue where &amp;quot;Nominal Aggregate Size (mm)&amp;quot; would not be correctly imported from the Size value of the parent sample&#039;s material in certain circumstances.&lt;br /&gt;
&lt;br /&gt;
Added &amp;quot;Nominal Aggregate Size (mm)&amp;quot; to the reported fields of the following tests, as required by the relevant standards:&lt;br /&gt;
* Los Angeles Abrasion Value [ASTM C 131 - 06] (ID 110160)&lt;br /&gt;
* Los Angeles Abrasion Value [ASTM C 131 - 06]* (ID 110357)&lt;br /&gt;
* LA Abrasion [AASHTO T 96 - 2010] (ID 110164)&lt;br /&gt;
&lt;br /&gt;
The field previously labelled &amp;quot;Test Grading&amp;quot; on the reduced screen Los Angeles Abrasion Value [ASTM C 131 - 06]* (ID 110357) will now be labelled &amp;quot;Grading Designation&amp;quot; to be consistent with the terminology of the standard.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1487 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| For the following tests, where masses are meant to be recorded in grams (g), the labels mistakenly indicated entry in pounds (lb):&lt;br /&gt;
* (ID 110338) Percentage of Fractured Particles in Coarse Aggregate [ASTM D 5821 - 2001]&lt;br /&gt;
* (ID 110343) Percentage of Fractured Particles in Coarse Aggregate [ASTM D 5821 - 2006]&lt;br /&gt;
These captions have been fixed.&lt;br /&gt;
&lt;br /&gt;
The test (ID 110344) Percentage of Fractured Particles in Coarse Aggregate (Imperial) [ASTM D 5821 - 2006], which has Nominal Maximum Size in IP units, has been changed so that by default masses are recorded in grams. A document-level option, &amp;quot;Record masses in lb&amp;quot;, is available for this test if data entry in pounds is still required. When using pounds, the mass can now be entered to the nearest 0.0001 lb.&lt;br /&gt;
&lt;br /&gt;
Masses for all of these tests are always given in grams on the test report.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1492 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug where field &amp;quot;WC Method&amp;quot; was always reported for Relative Compaction [ASTM] (ID 110201). This field will now only report when a moisture content method has been selected on a sibling In-Situ Density - Sand Cone Method [ASTM D 1556 - 2015] (ID 110305) test.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1581&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where the &amp;quot;Days Left on Site&amp;quot; field on the Concrete Sample can overflow and cause QESTField to show an error has been fixed.&lt;br /&gt;
&lt;br /&gt;
Additionally, for both QESTField and QESTLab, when the &amp;quot;Date Cast&amp;quot; is changed while &amp;quot;Days Left on Site&amp;quot; has a value, the &amp;quot;Date Received&amp;quot; will be calculated from these values.&lt;br /&gt;
&lt;br /&gt;
Previously, a shift in the &amp;quot;Date Cast&amp;quot; would produce a shift in the number of curing days (the &amp;quot;Standard Curing Days&amp;quot; field, shown as &amp;quot;Std Cure&amp;quot; in the concrete specimens grid in QESTLab). Now, when the &amp;quot;Date Received&amp;quot; is automatically shifted by the same number of days as the &amp;quot;Test Date&amp;quot;, it will not change the &amp;quot;Standard Curing Days&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1637 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where concrete specimens created via the concrete bulk entry (either by selecting the test group or using a work template) would cause an Error 13 message to appear when loading the Concrete Test Report.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1643 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where adding a Billable Item (ID 20040) without selecting a Test would cause &amp;quot;Invalid Use of Null&amp;quot; errors when adding an entry to the Fee Schedule list (ID 20005).&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1672 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where the PDF Password input for the QEST Administrator Console does not grey out properly has been fixed&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1673 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where an Error 5 message would appear when loading a Concrete Sample bulk entry screen for customers not licensed for the Concrete Mix list (ID 20021)&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1675 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where an Error 91 message could be raised when QESTLab triggered an update when no object was loaded (for example immediately after an object was deleted).&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1676&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where the &amp;quot;Age in Days&amp;quot; (AgeDays) field on the Concrete Specimen can overflow and cause QESTField to show an error has been fixed.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1683&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where the &amp;quot;Days Left On Site&amp;quot; field on the Concrete Specimen was not being updated from the Concrete Sample has been fixed.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1687 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug where results from a sibling grading test were imported over results entered onto Clay Lumps and Friable Particles test screens when &amp;quot;Ignore Grading Results&amp;quot; was checked.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1690 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where attempting to load a Wet/Dry Strength Variation test would raise an Error 13: Type Mismatch message.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1698 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed issue where SQL errors could occur when inserting new Billable Item (ID 20040) list entries.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1701 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug where concrete sample fields could clear for customers not licensed for the Concrete Mix list (ID 20021).&lt;br /&gt;
Fixed a bug where the bulk entry on the work order screen would refresh twice on loading.&lt;br /&gt;
On the work order screen&#039;s sample bulk entry, the Sample Type selection will now be locked when the screen is busy processing another request (eg. changing the number of samples).&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1705 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where Item Name and Charge would be cleared when automatic billing was triggered for manually entered Billing rows, where the associated Billable Item entry was set as editable.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1711 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where the Masonry Report (ID 18958) would show an &amp;quot;Error 91&amp;quot; message on load.&lt;br /&gt;
Fixed an issue where masonry specimens of type MORCUBE could not be reported.&lt;br /&gt;
&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=Template:QEST_Platform_4.5.2971&amp;diff=31396</id>
		<title>Template:QEST Platform 4.5.2971</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=Template:QEST_Platform_4.5.2971&amp;diff=31396"/>
		<updated>2018-02-19T06:50:34Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==QEST Platform 4.5.2971==&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
!Issue ID&lt;br /&gt;
!Release Notes&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1242&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| In QESTField, the Precision set against the specification is now taken into account when determining whether to style a result, e.g. colouring the text in red, as out of specification.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1243 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made for the entry and display of data in QESTField. Numeric results that have specification limits displayed against them will be formatted according to the Precision set in the specification.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1262 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| For the tests listed below, the equipment used for each test run can now be selected when Weighing Procedure is set to &amp;quot;Water&amp;quot;. Additionally, &amp;quot;Vacuum Flask&amp;quot; can no longer be selected as the Container Type when Weighing Procedure is set to &amp;quot;Water&amp;quot;.&lt;br /&gt;
* Max Specific Gravity and Density of Asphalt (Metric) [ASTM D 2041] (ID 117049)&lt;br /&gt;
* Rice Specific Gravity [ASTM D 2041] (ID 117050)&lt;br /&gt;
* Rice Specific Gravity [AASHTO T 209] (ID 117064)&lt;br /&gt;
* Rice Specific Gravity [NDOT T 324] (ID 117053)&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1265 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed several issues with the display of item status in the QESTLab tree:&lt;br /&gt;
* Items under &amp;quot;Tests/Documents&amp;quot; node will display the same status conditions as they would under the &amp;quot;Work Orders&amp;quot; node&lt;br /&gt;
* Reports which are &amp;quot;Ready to be Signed&amp;quot; will be displayed in blue when first loaded via a filter&lt;br /&gt;
* When loading a filter where items are grouped under multiple fields, combined status conditions will be displayed on every parent group (previously these only displayed on the item&#039;s immediate parent group)&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1271 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| When using the screen for Proctor - Standard [AASHTO T 99 - 2015] the Layers and Blows are now populated based on the selected Method.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1344 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where &amp;quot;Nominal Aggregate Size (mm)&amp;quot; was not saving correctly for US Los Angeles Abrasion Value screens in metric laboratories.&lt;br /&gt;
&lt;br /&gt;
Fixed an issue where &amp;quot;Nominal Aggregate Size (mm)&amp;quot; would not be correctly imported from the Size value of the parent sample&#039;s material in certain circumstances.&lt;br /&gt;
&lt;br /&gt;
Added &amp;quot;Nominal Aggregate Size (mm)&amp;quot; to the reported fields of the following tests, as required by the relevant standards:&lt;br /&gt;
* Los Angeles Abrasion Value [ASTM C 131 - 06] (ID 110160)&lt;br /&gt;
* Los Angeles Abrasion Value [ASTM C 131 - 06]* (ID 110357)&lt;br /&gt;
* LA Abrasion [AASHTO T 96 - 2010] (ID 110164)&lt;br /&gt;
&lt;br /&gt;
The field previously labelled &amp;quot;Test Grading&amp;quot; on the reduced screen Los Angeles Abrasion Value [ASTM C 131 - 06]* (ID 110357) will now be labelled &amp;quot;Grading Designation&amp;quot; to be consistent with the terminology of the standard.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1487 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| For the following tests, where masses are meant to be recorded in grams (g), the labels mistakenly indicated entry in pounds (lb):&lt;br /&gt;
* (ID 110338) Percentage of Fractured Particles in Coarse Aggregate [ASTM D 5821 - 2001]&lt;br /&gt;
* (ID 110343) Percentage of Fractured Particles in Coarse Aggregate [ASTM D 5821 - 2006]&lt;br /&gt;
These captions have been fixed.&lt;br /&gt;
&lt;br /&gt;
The test (ID 110344) Percentage of Fractured Particles in Coarse Aggregate (Imperial) [ASTM D 5821 - 2006], which has Nominal Maximum Size in IP units, has been changed so that by default masses are recorded in grams. A document-level option, &amp;quot;Record masses in lb&amp;quot;, is available for this test if data entry in pounds is still required. When using pounds, the mass can now be entered to the nearest 0.0001 lb.&lt;br /&gt;
&lt;br /&gt;
Masses for all of these tests are always given in grams on the test report.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1492 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug where field &amp;quot;WC Method&amp;quot; was always reported for Relative Compaction [ASTM] (ID 110201). This field will now only report when a moisture content method has been selected on a sibling In-Situ Density - Sand Cone Method [ASTM D 1556 - 2015] (ID 110305) test.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1581&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where the &amp;quot;Days Left on Site&amp;quot; field on the Concrete Sample can overflow and cause QESTField to show an error has been fixed.&lt;br /&gt;
&lt;br /&gt;
Additionally, for both QESTField and QESTLab, when the &amp;quot;Date Cast&amp;quot; is changed while &amp;quot;Days Left on Site&amp;quot; has a value, the &amp;quot;Date Received&amp;quot; will be calculated from these values.&lt;br /&gt;
&lt;br /&gt;
Previously, a shift in the &amp;quot;Date Cast&amp;quot; would produce a shift in the number of curing days (the &amp;quot;Standard Curing Days&amp;quot; field, shown as &amp;quot;Std Cure&amp;quot; in the concrete specimens grid in QESTLab). Now, when the &amp;quot;Date Received&amp;quot; is automatically shifted by the same number of days as the &amp;quot;Test Date&amp;quot;, it will not change the &amp;quot;Standard Curing Days&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1637 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where concrete specimens created via the concrete bulk entry (either by selecting the test group or using a work template) would cause an Error 13 message to appear when loading the Concrete Test Report.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1643 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where adding a Billable Item (ID 20040) without selecting a Test would cause &amp;quot;Invalid Use of Null&amp;quot; errors when adding an entry to the Fee Schedule list (ID 20005).&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1672 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where the PDF Password input for the QEST Administrator Console does not grey out properly has been fixed&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1673 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where an Error 5 message would appear when loading a Concrete Sample bulk entry screen for customers not licensed for the Concrete Mix list (ID 20021)&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1675 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where an Error 91 message could be raised when QESTLab triggered an update when no object was loaded (for example immediately after an object was deleted).&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1676&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where the &amp;quot;Age in Days&amp;quot; (AgeDays) field on the Concrete Specimen can overflow and cause QESTField to show an error has been fixed.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1683&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where the &amp;quot;Days Left On Site&amp;quot; field on the Concrete Specimen was not being updated from the Concrete Sample has been fixed.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1687 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug where results from a sibling grading test were imported over results entered onto Clay Lumps and Friable Particles test screens when &amp;quot;Ignore Grading Results&amp;quot; was checked.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1690 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where attempting to load a Wet/Dry Strength Variation test would raise an Error 13: Type Mismatch message.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1698 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed issue where SQL errors could occur when inserting new Billable Item (ID 20040) list entries.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1701 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug where concrete sample fields could clear for customers not licensed for the Concrete Mix list (ID 20021).&lt;br /&gt;
Fixed a bug where the bulk entry on the work order screen would refresh twice on loading.&lt;br /&gt;
On the work order screen&#039;s sample bulk entry, the Sample Type selection will now be locked when the screen is busy processing another request (eg. changing the number of samples).&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1705 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where Item Name and Charge would be cleared when automatic billing was triggered for manually entered Billing rows, where the associated Billable Item entry was set as editable.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1711 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where the Masonry Report (ID 18958) would show an &amp;quot;Error 91&amp;quot; message on load.&lt;br /&gt;
Fixed an issue where masonry specimens of type MORCUBE could not be reported.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1718 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug where items deleted in QESTField other than Concrete Samples were not deleted from the database.&lt;br /&gt;
&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=QEST_Platform_4.5.2971&amp;diff=31394</id>
		<title>QEST Platform 4.5.2971</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=QEST_Platform_4.5.2971&amp;diff=31394"/>
		<updated>2018-02-19T06:49:59Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==QEST Platform 4.5.2971==&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
!Issue ID&lt;br /&gt;
!Release Notes&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1242&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| In QESTField, the Precision set against the specification is now taken into account when determining whether to style a result, e.g. colouring the text in red, as out of specification.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1243 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made for the entry and display of data in QESTField. Numeric results that have specification limits displayed against them will be formatted according to the Precision set in the specification.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1262 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| For the tests listed below, the equipment used for each test run can now be selected when Weighing Procedure is set to &amp;quot;Water&amp;quot;. Additionally, &amp;quot;Vacuum Flask&amp;quot; can no longer be selected as the Container Type when Weighing Procedure is set to &amp;quot;Water&amp;quot;.&lt;br /&gt;
* Max Specific Gravity and Density of Asphalt (Metric) [ASTM D 2041] (ID 117049)&lt;br /&gt;
* Rice Specific Gravity [ASTM D 2041] (ID 117050)&lt;br /&gt;
* Rice Specific Gravity [AASHTO T 209] (ID 117064)&lt;br /&gt;
* Rice Specific Gravity [NDOT T 324] (ID 117053)&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1265 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed several issues with the display of item status in the QESTLab tree:&lt;br /&gt;
* Items under &amp;quot;Tests/Documents&amp;quot; node will display the same status conditions as they would under the &amp;quot;Work Orders&amp;quot; node&lt;br /&gt;
* Reports which are &amp;quot;Ready to be Signed&amp;quot; will be displayed in blue when first loaded via a filter&lt;br /&gt;
* When loading a filter where items are grouped under multiple fields, combined status conditions will be displayed on every parent group (previously these only displayed on the item&#039;s immediate parent group)&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1271 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| When using the screen for Proctor - Standard [AASHTO T 99 - 2015] the Layers and Blows are now populated based on the selected Method.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1344 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where &amp;quot;Nominal Aggregate Size (mm)&amp;quot; was not saving correctly for US Los Angeles Abrasion Value screens in metric laboratories.&lt;br /&gt;
&lt;br /&gt;
Fixed an issue where &amp;quot;Nominal Aggregate Size (mm)&amp;quot; would not be correctly imported from the Size value of the parent sample&#039;s material in certain circumstances.&lt;br /&gt;
&lt;br /&gt;
Added &amp;quot;Nominal Aggregate Size (mm)&amp;quot; to the reported fields of the following tests, as required by the relevant standards:&lt;br /&gt;
* Los Angeles Abrasion Value [ASTM C 131 - 06] (ID 110160)&lt;br /&gt;
* Los Angeles Abrasion Value [ASTM C 131 - 06]* (ID 110357)&lt;br /&gt;
* LA Abrasion [AASHTO T 96 - 2010] (ID 110164)&lt;br /&gt;
&lt;br /&gt;
The field previously labelled &amp;quot;Test Grading&amp;quot; on the reduced screen Los Angeles Abrasion Value [ASTM C 131 - 06]* (ID 110357) will now be labelled &amp;quot;Grading Designation&amp;quot; to be consistent with the terminology of the standard.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1487 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| For the following tests, where masses are meant to be recorded in grams (g), the labels mistakenly indicated entry in pounds (lb):&lt;br /&gt;
* (ID 110338) Percentage of Fractured Particles in Coarse Aggregate [ASTM D 5821 - 2001]&lt;br /&gt;
* (ID 110343) Percentage of Fractured Particles in Coarse Aggregate [ASTM D 5821 - 2006]&lt;br /&gt;
These captions have been fixed.&lt;br /&gt;
&lt;br /&gt;
The test (ID 110344) Percentage of Fractured Particles in Coarse Aggregate (Imperial) [ASTM D 5821 - 2006], which has Nominal Maximum Size in IP units, has been changed so that by default masses are recorded in grams. A document-level option, &amp;quot;Record masses in lb&amp;quot;, is available for this test if data entry in pounds is still required. When using pounds, the mass can now be entered to the nearest 0.0001 lb.&lt;br /&gt;
&lt;br /&gt;
Masses for all of these tests are always given in grams on the test report.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1492 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug where field &amp;quot;WC Method&amp;quot; was always reported for Relative Compaction [ASTM] (ID 110201). This field will now only report when a moisture content method has been selected on a sibling In-Situ Density - Sand Cone Method [ASTM D 1556 - 2015] (ID 110305) test.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1581&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where the &amp;quot;Days Left on Site&amp;quot; field on the Concrete Sample can overflow and cause QESTField to show an error has been fixed.&lt;br /&gt;
&lt;br /&gt;
Additionally, for both QESTField and QESTLab, when the &amp;quot;Date Cast&amp;quot; is changed while &amp;quot;Days Left on Site&amp;quot; has a value, the &amp;quot;Date Received&amp;quot; will be calculated from these values.&lt;br /&gt;
&lt;br /&gt;
Previously, a shift in the &amp;quot;Date Cast&amp;quot; would produce a shift in the number of curing days (the &amp;quot;Standard Curing Days&amp;quot; field, shown as &amp;quot;Std Cure&amp;quot; in the concrete specimens grid in QESTLab). Now, when the &amp;quot;Date Received&amp;quot; is automatically shifted by the same number of days as the &amp;quot;Test Date&amp;quot;, it will not change the &amp;quot;Standard Curing Days&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1637 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where concrete specimens created via the concrete bulk entry (either by selecting the test group or using a work template) would cause an Error 13 message to appear when loading the Concrete Test Report.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1643 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where adding a Billable Item (ID 20040) without selecting a Test would cause &amp;quot;Invalid Use of Null&amp;quot; errors when adding an entry to the Fee Schedule list (ID 20005).&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1672 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where the PDF Password input for the QEST Administrator Console does not grey out properly has been fixed&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1673 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where an Error 5 message would appear when loading a Concrete Sample bulk entry screen for customers not licensed for the Concrete Mix list (ID 20021)&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1675 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where an Error 91 message could be raised when QESTLab triggered an update when no object was loaded (for example immediately after an object was deleted).&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1676&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where the &amp;quot;Age in Days&amp;quot; (AgeDays) field on the Concrete Specimen can overflow and cause QESTField to show an error has been fixed.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1683&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where the &amp;quot;Days Left On Site&amp;quot; field on the Concrete Specimen was not being updated from the Concrete Sample has been fixed.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1687 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug where results from a sibling grading test were imported over results entered onto Clay Lumps and Friable Particles test screens when &amp;quot;Ignore Grading Results&amp;quot; was checked.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1690 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where attempting to load a Wet/Dry Strength Variation test would raise an Error 13: Type Mismatch message.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1698 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed issue where SQL errors could occur when inserting new Billable Item (ID 20040) list entries.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1701 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug where concrete sample fields could clear for customers not licensed for the Concrete Mix list (ID 20021).&lt;br /&gt;
Fixed a bug where the bulk entry on the work order screen would refresh twice on loading.&lt;br /&gt;
On the work order screen&#039;s sample bulk entry, the Sample Type selection will now be locked when the screen is busy processing another request (eg. changing the number of samples).&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1705 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where Item Name and Charge would be cleared when automatic billing was triggered for manually entered Billing rows, where the associated Billable Item entry was set as editable.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1711 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where the Masonry Report (ID 18958) would show an &amp;quot;Error 91&amp;quot; message on load.&lt;br /&gt;
Fixed an issue where masonry specimens of type MORCUBE could not be reported.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1718 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug where items deleted in QESTField other than Concrete Samples were not deleted from the database.&lt;br /&gt;
&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=QEST_Platform_4.5.2971&amp;diff=31393</id>
		<title>QEST Platform 4.5.2971</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=QEST_Platform_4.5.2971&amp;diff=31393"/>
		<updated>2018-02-19T06:49:51Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==QEST Platform 4.5.X==&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
!Issue ID&lt;br /&gt;
!Release Notes&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1242&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| In QESTField, the Precision set against the specification is now taken into account when determining whether to style a result, e.g. colouring the text in red, as out of specification.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1243 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made for the entry and display of data in QESTField. Numeric results that have specification limits displayed against them will be formatted according to the Precision set in the specification.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1262 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| For the tests listed below, the equipment used for each test run can now be selected when Weighing Procedure is set to &amp;quot;Water&amp;quot;. Additionally, &amp;quot;Vacuum Flask&amp;quot; can no longer be selected as the Container Type when Weighing Procedure is set to &amp;quot;Water&amp;quot;.&lt;br /&gt;
* Max Specific Gravity and Density of Asphalt (Metric) [ASTM D 2041] (ID 117049)&lt;br /&gt;
* Rice Specific Gravity [ASTM D 2041] (ID 117050)&lt;br /&gt;
* Rice Specific Gravity [AASHTO T 209] (ID 117064)&lt;br /&gt;
* Rice Specific Gravity [NDOT T 324] (ID 117053)&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1265 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed several issues with the display of item status in the QESTLab tree:&lt;br /&gt;
* Items under &amp;quot;Tests/Documents&amp;quot; node will display the same status conditions as they would under the &amp;quot;Work Orders&amp;quot; node&lt;br /&gt;
* Reports which are &amp;quot;Ready to be Signed&amp;quot; will be displayed in blue when first loaded via a filter&lt;br /&gt;
* When loading a filter where items are grouped under multiple fields, combined status conditions will be displayed on every parent group (previously these only displayed on the item&#039;s immediate parent group)&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1271 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| When using the screen for Proctor - Standard [AASHTO T 99 - 2015] the Layers and Blows are now populated based on the selected Method.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1344 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where &amp;quot;Nominal Aggregate Size (mm)&amp;quot; was not saving correctly for US Los Angeles Abrasion Value screens in metric laboratories.&lt;br /&gt;
&lt;br /&gt;
Fixed an issue where &amp;quot;Nominal Aggregate Size (mm)&amp;quot; would not be correctly imported from the Size value of the parent sample&#039;s material in certain circumstances.&lt;br /&gt;
&lt;br /&gt;
Added &amp;quot;Nominal Aggregate Size (mm)&amp;quot; to the reported fields of the following tests, as required by the relevant standards:&lt;br /&gt;
* Los Angeles Abrasion Value [ASTM C 131 - 06] (ID 110160)&lt;br /&gt;
* Los Angeles Abrasion Value [ASTM C 131 - 06]* (ID 110357)&lt;br /&gt;
* LA Abrasion [AASHTO T 96 - 2010] (ID 110164)&lt;br /&gt;
&lt;br /&gt;
The field previously labelled &amp;quot;Test Grading&amp;quot; on the reduced screen Los Angeles Abrasion Value [ASTM C 131 - 06]* (ID 110357) will now be labelled &amp;quot;Grading Designation&amp;quot; to be consistent with the terminology of the standard.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1487 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| For the following tests, where masses are meant to be recorded in grams (g), the labels mistakenly indicated entry in pounds (lb):&lt;br /&gt;
* (ID 110338) Percentage of Fractured Particles in Coarse Aggregate [ASTM D 5821 - 2001]&lt;br /&gt;
* (ID 110343) Percentage of Fractured Particles in Coarse Aggregate [ASTM D 5821 - 2006]&lt;br /&gt;
These captions have been fixed.&lt;br /&gt;
&lt;br /&gt;
The test (ID 110344) Percentage of Fractured Particles in Coarse Aggregate (Imperial) [ASTM D 5821 - 2006], which has Nominal Maximum Size in IP units, has been changed so that by default masses are recorded in grams. A document-level option, &amp;quot;Record masses in lb&amp;quot;, is available for this test if data entry in pounds is still required. When using pounds, the mass can now be entered to the nearest 0.0001 lb.&lt;br /&gt;
&lt;br /&gt;
Masses for all of these tests are always given in grams on the test report.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1492 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug where field &amp;quot;WC Method&amp;quot; was always reported for Relative Compaction [ASTM] (ID 110201). This field will now only report when a moisture content method has been selected on a sibling In-Situ Density - Sand Cone Method [ASTM D 1556 - 2015] (ID 110305) test.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1581&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where the &amp;quot;Days Left on Site&amp;quot; field on the Concrete Sample can overflow and cause QESTField to show an error has been fixed.&lt;br /&gt;
&lt;br /&gt;
Additionally, for both QESTField and QESTLab, when the &amp;quot;Date Cast&amp;quot; is changed while &amp;quot;Days Left on Site&amp;quot; has a value, the &amp;quot;Date Received&amp;quot; will be calculated from these values.&lt;br /&gt;
&lt;br /&gt;
Previously, a shift in the &amp;quot;Date Cast&amp;quot; would produce a shift in the number of curing days (the &amp;quot;Standard Curing Days&amp;quot; field, shown as &amp;quot;Std Cure&amp;quot; in the concrete specimens grid in QESTLab). Now, when the &amp;quot;Date Received&amp;quot; is automatically shifted by the same number of days as the &amp;quot;Test Date&amp;quot;, it will not change the &amp;quot;Standard Curing Days&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1637 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where concrete specimens created via the concrete bulk entry (either by selecting the test group or using a work template) would cause an Error 13 message to appear when loading the Concrete Test Report.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1643 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where adding a Billable Item (ID 20040) without selecting a Test would cause &amp;quot;Invalid Use of Null&amp;quot; errors when adding an entry to the Fee Schedule list (ID 20005).&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1672 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where the PDF Password input for the QEST Administrator Console does not grey out properly has been fixed&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1673 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where an Error 5 message would appear when loading a Concrete Sample bulk entry screen for customers not licensed for the Concrete Mix list (ID 20021)&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1675 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where an Error 91 message could be raised when QESTLab triggered an update when no object was loaded (for example immediately after an object was deleted).&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1676&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where the &amp;quot;Age in Days&amp;quot; (AgeDays) field on the Concrete Specimen can overflow and cause QESTField to show an error has been fixed.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1683&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where the &amp;quot;Days Left On Site&amp;quot; field on the Concrete Specimen was not being updated from the Concrete Sample has been fixed.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1687 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug where results from a sibling grading test were imported over results entered onto Clay Lumps and Friable Particles test screens when &amp;quot;Ignore Grading Results&amp;quot; was checked.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1690 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where attempting to load a Wet/Dry Strength Variation test would raise an Error 13: Type Mismatch message.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1698 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed issue where SQL errors could occur when inserting new Billable Item (ID 20040) list entries.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1701 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug where concrete sample fields could clear for customers not licensed for the Concrete Mix list (ID 20021).&lt;br /&gt;
Fixed a bug where the bulk entry on the work order screen would refresh twice on loading.&lt;br /&gt;
On the work order screen&#039;s sample bulk entry, the Sample Type selection will now be locked when the screen is busy processing another request (eg. changing the number of samples).&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1705 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where Item Name and Charge would be cleared when automatic billing was triggered for manually entered Billing rows, where the associated Billable Item entry was set as editable.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1711 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where the Masonry Report (ID 18958) would show an &amp;quot;Error 91&amp;quot; message on load.&lt;br /&gt;
Fixed an issue where masonry specimens of type MORCUBE could not be reported.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1718 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug where items deleted in QESTField other than Concrete Samples were not deleted from the database.&lt;br /&gt;
&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=Template:QEST_Platform_4.5.2951&amp;diff=31390</id>
		<title>Template:QEST Platform 4.5.2951</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=Template:QEST_Platform_4.5.2951&amp;diff=31390"/>
		<updated>2018-01-30T22:48:39Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==QEST Platform 4.5.2951==&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&amp;quot;&lt;br /&gt;
!Issue ID&lt;br /&gt;
!Release Notes&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1631&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where the Update Billing Documents form would appear to freeze while updating a set of Billing documents. Some minor performance improvements were also made to this functionality.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1647&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a &amp;quot;Type Mismatch&amp;quot; error that could occur in the  Update Billing functionality when a blank billing row was present in a billing document.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1600&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Passwords for secure PDFs can now be set in the QEST Administrator Console under &amp;quot;Configuration &amp;gt; Options &amp;gt; Permissions &amp;gt; PDF ...&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1630&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed issues with selecting and auto-filling entries of the list Concrete Mix (ID 20021) on the Concrete Sample bulk entry screen when multiple mixes had the same ProductCode. Note QESTLab only requires ProductCode be unique against the associated Concrete Supplier and Concrete Plant.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1641&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where the &amp;quot;Density&amp;quot; value from a concrete sample was being copied to its specimens upon creation (the density of each specimen should only be that obtained from measurements performed on that specimen).&lt;br /&gt;
&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=QEST_Platform_4.5.2951&amp;diff=31388</id>
		<title>QEST Platform 4.5.2951</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=QEST_Platform_4.5.2951&amp;diff=31388"/>
		<updated>2018-01-30T22:47:55Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==QEST Platform 4.5.2951==&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&amp;quot;&lt;br /&gt;
!Issue ID&lt;br /&gt;
!Release Notes&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1631&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where the Update Billing Documents form would appear to freeze while updating a set of Billing documents. Some minor performance improvements were also made to this functionality.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1647&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a &amp;quot;Type Mismatch&amp;quot; error that could occur in the  Update Billing functionality when a blank billing row was present in a billing document.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1600&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Passwords for secure PDFs can now be set in the QEST Administrator Console under &amp;quot;Configuration &amp;gt; Options &amp;gt; Permissions &amp;gt; PDF ...&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1630&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed issues with selecting and auto-filling entries of the list Concrete Mix (ID 20021) on the Concrete Sample bulk entry screen when multiple mixes had the same ProductCode. Note QESTLab only requires ProductCode be unique against the associated Concrete Supplier and Concrete Plant.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1641&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where the &amp;quot;Density&amp;quot; value from a concrete sample was being copied to its specimens upon creation (the density of each specimen should only be that obtained from measurements performed on that specimen).&lt;br /&gt;
&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=Template:QEST_Platform_4.5.2939&amp;diff=31385</id>
		<title>Template:QEST Platform 4.5.2939</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=Template:QEST_Platform_4.5.2939&amp;diff=31385"/>
		<updated>2018-01-18T21:53:36Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==QEST Platform 4.5.2939==&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
!Issue ID&lt;br /&gt;
!Release Notes&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1632&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug which caused some combo list selections to clear when a test screen was refreshed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1629 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QESTLab now runs on 32-bit systems again. Errors showing &amp;quot;Error 373: Failed to load from MSCOMCTL.OCX&amp;quot; are no longer seen.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1598 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| TRN will no longer be locked on applicable bulk entry views for Aggregate/Soil samples (ID 1001) and Asphalt samples (ID 1701). &lt;br /&gt;
Note that when TRN is changed on the Work Order the new value will replace the sample-level TRN.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1576 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where the user cannot click out of the Client / Project / Project owner code field on the Work Order screen in QESTLab has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1574 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| On the following calibration worksheets for Balance (ID 30005), if Check Mass is greater than the largest load on the associated Balance Calibration Data Entry (ID 31010) worksheet then fields will now import from the reading with the largest load as long as Check Mass is within the specified Scale Range.&lt;br /&gt;
* Balance Single-Point Check [NATA Technical Note 13] (ID 31005)&lt;br /&gt;
* Balance Single-Point Check [NATA Technical Note 13 - 2014] (ID 31017)&lt;br /&gt;
* Balance Single-Point Check when Moving [NATA Technical Note 13] (ID 31008) &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1573 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A performance improvement has been made to the loading of work order data for QESTField Scheduler. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1572 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made to improve performance when loading technician data for the QESTField Scheduler.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1571 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made to improve performance when loading laboratory data for the QESTField Scheduler. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1568&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Removed QESTLab Windows version requirements from splash screen.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1567 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The QESTField AU Concrete screen&#039;s &amp;quot;Truck does not match&amp;quot; prompt, when importing from a Docket, has been reworded.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1549 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| UI performance when editing user document configuration now scales a lot further when editing tables that have large numbers of columns. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1548 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following changes have been made for California Bearing Ratio tests with IDs 10215,10222,10223,10224,10225,10226,10227,10228,10235,10237,10239,10592:&lt;br /&gt;
* The Raw Force value recorded at 0.0mm depth is now considered as a zero correction and is used to calculate all Force values.&lt;br /&gt;
* The zero offset will be copied to Seating values if no values are entered for Seating values.&lt;br /&gt;
* A new document level option is created to allow copying seating values to CBR Results tab as zero correction.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1547 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following for default format is now used for all user documents:&lt;br /&gt;
* Field Type, Default Format&lt;br /&gt;
* Integer, 0&lt;br /&gt;
* Decimal, 3sf&lt;br /&gt;
* Bit, List:True;Flase&lt;br /&gt;
* Money, 0.00&lt;br /&gt;
* Float, 3sf&lt;br /&gt;
* DateTime, Short Date&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1545 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Bulk publishing no longer produces corrupt PDFs due to multiple report types (e.g. Active Reports and PDFs) being passed in. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1544 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Specification Group names can now be up to 50 characters (previously set to 25) &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1543 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where lab-specific technicians could appear in dropdown selections when the Sampled By list (ID 20006) was set to &amp;quot;Global Only&amp;quot; has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1514 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The header &amp;quot;Compressive Strength of Concrete Cylinders Cast in Place in Cylindrical Molds&amp;quot; of CIP100 specimens in Concrete Test Reports is now corrected to refer &amp;quot;Cylindrical&amp;quot; instead of &amp;quot;Cylinderical&amp;quot;. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1479 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| For the following moisture content test screens, the field Nominal Aggregate Size (mm) has been replaced with the dropdown selection Maximum Particle Size to indicate the maximum sieve size with 100% material passing in accordance with standard ASTM D 2216.&lt;br /&gt;
* Water Content of Soil and Rock [ASTM D 2216] (ID 110060)&lt;br /&gt;
* Moisture Content of Soil and Rock [ASTM D 2216 - 2010] (ID 110066)&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1439 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where publishing an email to contacts with commas in their name could raise a &amp;quot;Subscript out of range&amp;quot; error. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1366 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where user document column names containing hyphens could not be deleted has been fixed.  These are now correctly enclosed in square brackets, and escaped if necessary. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1365 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The moisture content rounding of &amp;quot;oven-dried&amp;quot; moisture content is to nearest 0.1% for Moisture, Ash and Organic Content [ASTM D 2974 - 2007]. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1364 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where Density Offset Report (ID 17036) could not be loaded has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1363 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The test method no longer reports twice on the nuclear density report. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1362 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following can no longer appear in the Accredited Documents trees in the QEST Administrator Console, as they are not applicable:&lt;br /&gt;
* (ID 18010) Billing&lt;br /&gt;
* (ID 18015) Billing Summary&lt;br /&gt;
* (ID 18019) Invoice&lt;br /&gt;
* (ID 18020) Timekeeping&lt;br /&gt;
* (ID 18021) Timekeeping Records&lt;br /&gt;
* (ID 90022) Archived Test Report&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1361 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The bug where the Hanson &amp;quot;Concrete Test Delete Export&amp;quot; integrator was not being invoked correctly from QESTField/QESTNET has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1360 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Reports with NZGEO Custom Header now load without errors when the preliminary field value is null.&lt;br /&gt;
&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=QEST_Platform_4.5.2939&amp;diff=31384</id>
		<title>QEST Platform 4.5.2939</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=QEST_Platform_4.5.2939&amp;diff=31384"/>
		<updated>2018-01-18T21:53:21Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==QEST Platform 4.5.2939==&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
!Issue ID&lt;br /&gt;
!Release Notes&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1632&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug which caused some combo list selections to clear when a test screen was refreshed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1629 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QESTLab now runs on 32-bit systems again. Errors showing &amp;quot;Error 373: Failed to load from MSCOMCTL.OCX&amp;quot; are no longer seen.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1598 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| TRN will no longer be locked on applicable bulk entry views for Aggregate/Soil samples (ID 1001) and Asphalt samples (ID 1701). &lt;br /&gt;
Note that when TRN is changed on the Work Order the new value will replace the sample-level TRN.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1576 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where the user cannot click out of the Client / Project / Project owner code field on the Work Order screen in QESTLab has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1574 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| On the following calibration worksheets for Balance (ID 30005), if Check Mass is greater than the largest load on the associated Balance Calibration Data Entry (ID 31010) worksheet then fields will now import from the reading with the largest load as long as Check Mass is within the specified Scale Range.&lt;br /&gt;
* Balance Single-Point Check [NATA Technical Note 13] (ID 31005)&lt;br /&gt;
* Balance Single-Point Check [NATA Technical Note 13 - 2014] (ID 31017)&lt;br /&gt;
* Balance Single-Point Check when Moving [NATA Technical Note 13] (ID 31008) &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1573 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A performance improvement has been made to the loading of work order data for QESTField Scheduler. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1572 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made to improve performance when loading technician data for the QESTField Scheduler.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1571 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made to improve performance when loading laboratory data for the QESTField Scheduler. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1568&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Removed QESTLab Windows version requirements from splash screen.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1567 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The QESTField AU Concrete screen&#039;s &amp;quot;Truck does not match&amp;quot; prompt, when importing from a Docket, has been reworded.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1549 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| UI performance when editing user document configuration now scales a lot further when editing tables that have large numbers of columns. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1548 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following changes have been made for California Bearing Ratio tests with IDs 10215,10222,10223,10224,10225,10226,10227,10228,10235,10237,10239,10592:&lt;br /&gt;
* The Raw Force value recorded at 0.0mm depth is now considered as a zero correction and is used to calculate all Force values.&lt;br /&gt;
* The zero offset will be copied to Seating values if no values are entered for Seating values.&lt;br /&gt;
* A new document level option is created to allow copying seating values to CBR Results tab as zero correction.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1547 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following for default format is now used for all user documents:&lt;br /&gt;
* Field Type, Default Format&lt;br /&gt;
* Integer, 0&lt;br /&gt;
* Decimal, 3sf&lt;br /&gt;
* Bit, List:True;Flase&lt;br /&gt;
* Money, 0.00&lt;br /&gt;
* Float, 3sf&lt;br /&gt;
* DateTime, Short Date&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1545 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Bulk publishing no longer produces corrupt PDFs due to multiple report types (e.g. Active Reports and PDFs) being passed in. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1544 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Specification Group names can now be up to 50 characters (previously set to 25) &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1543 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where lab-specific technicians could appear in dropdown selections when the Sampled By list (ID 20006) was set to &amp;quot;Global Only&amp;quot; has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1514 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The header &amp;quot;Compressive Strength of Concrete Cylinders Cast in Place in Cylindrical Molds&amp;quot; of CIP100 specimens in Concrete Test Reports is now corrected to refer &amp;quot;Cylindrical&amp;quot; instead of &amp;quot;Cylinderical&amp;quot;. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1479 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| For the following moisture content test screens, the field Nominal Aggregate Size (mm) has been replaced with the dropdown selection Maximum Particle Size to indicate the maximum sieve size with 100% material passing in accordance with standard ASTM D 2216.&lt;br /&gt;
* Water Content of Soil and Rock [ASTM D 2216] (ID 110060)&lt;br /&gt;
* Moisture Content of Soil and Rock [ASTM D 2216 - 2010] (ID 110066)&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1439 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where publishing an email to contacts with commas in their name could raise a &amp;quot;Subscript out of range&amp;quot; error. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1366 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where user document column names containing hyphens could not be deleted has been fixed.  These are now correctly enclosed in square brackets, and escaped if necessary. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1365 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The moisture content rounding of &amp;quot;oven-dried&amp;quot; moisture content is to nearest 0.1% for Moisture, Ash and Organic Content [ASTM D 2974 - 2007]. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1364 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where Density Offset Report (ID 17036) could not be loaded has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1363 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The test method no longer reports twice on the nuclear density report. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1362 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following can no longer appear in the Accredited Documents trees in the QEST Administrator Console, as they are not applicable:&lt;br /&gt;
* (ID 18010) Billing&lt;br /&gt;
* (ID 18015) Billing Summary&lt;br /&gt;
* (ID 18019) Invoice&lt;br /&gt;
* (ID 18020) Timekeeping&lt;br /&gt;
* (ID 18021) Timekeeping Records&lt;br /&gt;
* (ID 90022) Archived Test Report&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1361 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The bug where the Hanson &amp;quot;Concrete Test Delete Export&amp;quot; integrator was not being invoked correctly from QESTField/QESTNET has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM&amp;amp;#8209;1360 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Reports with NZGEO Custom Header now load without errors when the preliminary field value is null.&lt;br /&gt;
&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=Template:QEST_Platform_4.5.2939&amp;diff=31383</id>
		<title>Template:QEST Platform 4.5.2939</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=Template:QEST_Platform_4.5.2939&amp;diff=31383"/>
		<updated>2018-01-18T03:54:31Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==QEST Platform 4.5.2939==&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
!Issue ID&lt;br /&gt;
!Release Notes&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1632&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug which caused some combo list selections to clear when a test screen was refreshed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1629 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QESTLab now runs on 32-bit systems again. Errors showing &amp;quot;Error 373: Failed to load from MSCOMCTL.OCX&amp;quot; are no longer seen.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1598 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| TRN will no longer be locked on applicable bulk entry views for Aggregate/Soil samples (ID 1001) and Asphalt samples (ID 1701). &lt;br /&gt;
Note that when TRN is changed on the Work Order the new value will replace the sample-level TRN.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1576 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where the user cannot click out of the Client / Project / Project owner code field on the Work Order screen in QESTLab has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1574 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| On the following calibration worksheets for Balance (ID 30005), if Check Mass is greater than the largest load on the associated Balance Calibration Data Entry (ID 31010) worksheet then fields will now import from the reading with the largest load as long as Check Mass is within the specified Scale Range.&lt;br /&gt;
* Balance Single-Point Check [NATA Technical Note 13] (ID 31005)&lt;br /&gt;
* Balance Single-Point Check [NATA Technical Note 13 - 2014] (ID 31017)&lt;br /&gt;
* Balance Single-Point Check when Moving [NATA Technical Note 13] (ID 31008) &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1573 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A performance improvement has been made to the loading of work order data for QESTField Scheduler. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1572 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made to improve performance when loading technician data for the QESTField Scheduler.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1571 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made to improve performance when loading laboratory data for the QESTField Scheduler. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1568&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Removed QESTLab Windows version requirements from splash screen.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1567 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The QESTField AU Concrete screen&#039;s &amp;quot;Truck does not match&amp;quot; prompt, when importing from a Docket, has been reworded.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1549 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| UI performance when editing user document configuration now scales a lot further when editing tables that have large numbers of columns. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1548 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following changes have been made for California Bearing Ratio tests with IDs 10215,10222,10223,10224,10225,10226,10227,10228,10235,10237,10239,10592:&lt;br /&gt;
* The Raw Force value recorded at 0.0mm depth is now considered as a zero correction and is used to calculate all Force values.&lt;br /&gt;
* The zero offset will be copied to Seating values if no values are entered for Seating values.&lt;br /&gt;
* A new document level option is created to allow copying seating values to CBR Results tab as zero correction.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1547 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following for default format is now used for all user documents:&lt;br /&gt;
* Field Type, Default Format&lt;br /&gt;
* Integer, 0&lt;br /&gt;
* Decimal, 3sf&lt;br /&gt;
* Bit, List:True;Flase&lt;br /&gt;
* Money, 0.00&lt;br /&gt;
* Float, 3sf&lt;br /&gt;
* DateTime, Short Date&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1545 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Bulk publishing no longer produces corrupt PDFs due to multiple report types (e.g. Active Reports and PDFs) being passed in. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1544 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Specification Group names can now be up to 50 characters (previously set to 25) &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1543 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where lab-specific technicians could appear in dropdown selections when the Sampled By list (ID 20006) was set to &amp;quot;Global Only&amp;quot; has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1514 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The header &amp;quot;Compressive Strength of Concrete Cylinders Cast in Place in Cylindrical Molds&amp;quot; of CIP100 specimens in Concrete Test Reports is now corrected to refer &amp;quot;Cylindrical&amp;quot; instead of &amp;quot;Cylinderical&amp;quot;. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1479 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| For the following moisture content test screens, the field Nominal Aggregate Size (mm) has been replaced with the dropdown selection Maximum Particle Size to indicate the maximum sieve size with 100% material passing in accordance with standard ASTM D 2216.&lt;br /&gt;
* Water Content of Soil and Rock [ASTM D 2216] (ID 110060)&lt;br /&gt;
* Moisture Content of Soil and Rock [ASTM D 2216 - 2010] (ID 110066)&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1439 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where publishing an email to contacts with commas in their name could raise a &amp;quot;Subscript out of range&amp;quot; error. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1366 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where user document column names containing hyphens could not be deleted has been fixed.  These are now correctly enclosed in square brackets, and escaped if necessary. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1365 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The moisture content rounding of &amp;quot;oven-dried&amp;quot; moisture content is to nearest 0.1% for Moisture, Ash and Organic Content [ASTM D 2974 - 2007]. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1364 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where Density Offset Report (ID 17036) could not be loaded has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1363 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The test method no longer reports twice on the nuclear density report. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1362 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following can no longer appear in the Accredited Documents trees in the QEST Administrator Console, as they are not applicable:&lt;br /&gt;
* (ID 18010) Billing&lt;br /&gt;
* (ID 18015) Billing Summary&lt;br /&gt;
* (ID 18019) Invoice&lt;br /&gt;
* (ID 18020) Timekeeping&lt;br /&gt;
* (ID 18021) Timekeeping Records&lt;br /&gt;
* (ID 90022) Archived Test Report&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1361 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The bug where the Hanson &amp;quot;Concrete Test Delete Export&amp;quot; integrator was not being invoked correctly from QESTField/QESTNET has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1360 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Reports with NZGEO Custom Header now load without errors when the preliminary field value is null.&lt;br /&gt;
&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=QEST_Platform_4.5.2939&amp;diff=31382</id>
		<title>QEST Platform 4.5.2939</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=QEST_Platform_4.5.2939&amp;diff=31382"/>
		<updated>2018-01-18T03:54:07Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==QEST Platform 4.5.2939==&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
!Issue ID&lt;br /&gt;
!Release Notes&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1632&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug which caused some combo list selections to clear when a test screen was refreshed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1629 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QESTLab now runs on 32-bit systems again. Errors showing &amp;quot;Error 373: Failed to load from MSCOMCTL.OCX&amp;quot; are no longer seen.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1598 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| TRN will no longer be locked on applicable bulk entry views for Aggregate/Soil samples (ID 1001) and Asphalt samples (ID 1701). &lt;br /&gt;
Note that when TRN is changed on the Work Order the new value will replace the sample-level TRN.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1576 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where the user cannot click out of the Client / Project / Project owner code field on the Work Order screen in QESTLab has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1574 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| On the following calibration worksheets for Balance (ID 30005), if Check Mass is greater than the largest load on the associated Balance Calibration Data Entry (ID 31010) worksheet then fields will now import from the reading with the largest load as long as Check Mass is within the specified Scale Range.&lt;br /&gt;
* Balance Single-Point Check [NATA Technical Note 13] (ID 31005)&lt;br /&gt;
* Balance Single-Point Check [NATA Technical Note 13 - 2014] (ID 31017)&lt;br /&gt;
* Balance Single-Point Check when Moving [NATA Technical Note 13] (ID 31008) &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1573 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A performance improvement has been made to the loading of work order data for QESTField Scheduler. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1572 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made to improve performance when loading technician data for the QESTField Scheduler.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1571 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made to improve performance when loading laboratory data for the QESTField Scheduler. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1568&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Removed QESTLab Windows version requirements from splash screen.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1567 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The QESTField AU Concrete screen&#039;s &amp;quot;Truck does not match&amp;quot; prompt, when importing from a Docket, has been reworded.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1549 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| UI performance when editing user document configuration now scales a lot further when editing tables that have large numbers of columns. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1548 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following changes have been made for California Bearing Ratio tests with IDs 10215,10222,10223,10224,10225,10226,10227,10228,10235,10237,10239,10592:&lt;br /&gt;
* The Raw Force value recorded at 0.0mm depth is now considered as a zero correction and is used to calculate all Force values.&lt;br /&gt;
* The zero offset will be copied to Seating values if no values are entered for Seating values.&lt;br /&gt;
* A new document level option is created to allow copying seating values to CBR Results tab as zero correction.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1547 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following for default format is now used for all user documents:&lt;br /&gt;
* Field Type, Default Format&lt;br /&gt;
* Integer, 0&lt;br /&gt;
* Decimal, 3sf&lt;br /&gt;
* Bit, List:True;Flase&lt;br /&gt;
* Money, 0.00&lt;br /&gt;
* Float, 3sf&lt;br /&gt;
* DateTime, Short Date&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1545 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Bulk publishing no longer produces corrupt PDFs due to multiple report types (e.g. Active Reports and PDFs) being passed in. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1544 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Specification Group names can now be up to 50 characters (previously set to 25) &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1543 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where lab-specific technicians could appear in dropdown selections when the Sampled By list (ID 20006) was set to &amp;quot;Global Only&amp;quot; has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1514 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The header &amp;quot;Compressive Strength of Concrete Cylinders Cast in Place in Cylindrical Molds&amp;quot; of CIP100 specimens in Concrete Test Reports is now corrected to refer &amp;quot;Cylindrical&amp;quot; instead of &amp;quot;Cylinderical&amp;quot;. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1479 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| For the following moisture content test screens, the field Nominal Aggregate Size (mm) has been replaced with the dropdown selection Maximum Particle Size to indicate the maximum sieve size with 100% material passing in accordance with standard ASTM D 2216.&lt;br /&gt;
* Water Content of Soil and Rock [ASTM D 2216] (ID 110060)&lt;br /&gt;
* Moisture Content of Soil and Rock [ASTM D 2216 - 2010] (ID 110066)&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1439 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where publishing an email to contacts with commas in their name could raise a &amp;quot;Subscript out of range&amp;quot; error. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1366 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where user document column names containing hyphens could not be deleted has been fixed.  These are now correctly enclosed in square brackets, and escaped if necessary. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1365 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The moisture content rounding of &amp;quot;oven-dried&amp;quot; moisture content is to nearest 0.1% for Moisture, Ash and Organic Content [ASTM D 2974 - 2007]. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1364 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where Density Offset Report (ID 17036) could not be loaded has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1363 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The test method no longer reports twice on the nuclear density report. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1362 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following can no longer appear in the Accredited Documents trees in the QEST Administrator Console, as they are not applicable:&lt;br /&gt;
* (ID 18010) Billing&lt;br /&gt;
* (ID 18015) Billing Summary&lt;br /&gt;
* (ID 18019) Invoice&lt;br /&gt;
* (ID 18020) Timekeeping&lt;br /&gt;
* (ID 18021) Timekeeping Records&lt;br /&gt;
* (ID 90022) Archived Test Report&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1361 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The bug where the Hanson &amp;quot;Concrete Test Delete Export&amp;quot; integrator was not being invoked correctly from QESTField/QESTNET has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1360 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Reports with NZGEO Custom Header now load without errors when the preliminary field value is null.&lt;br /&gt;
&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=Template:QEST_Platform_4.5.2939&amp;diff=31381</id>
		<title>Template:QEST Platform 4.5.2939</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=Template:QEST_Platform_4.5.2939&amp;diff=31381"/>
		<updated>2018-01-18T03:27:49Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==QEST Platform 4.5.2939==&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
!Issue ID&lt;br /&gt;
!Release Notes&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1632&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug which caused some combo list selections to clear when a test screen was refreshed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1629 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QESTLab now runs on 32-bit systems again. Errors showing &amp;quot;Error 373: Failed to load from MSCOMCTL.OCX&amp;quot; are no longer seen.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1598 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| TRN will no longer be locked on applicable bulk entry views for Aggregate/Soil samples (ID 1001) and Asphalt samples (ID 1701). &lt;br /&gt;
Note that when TRN is changed on the Work Order the new value will replace the sample-level TRN.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1576 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where the user cannot click out of the Client / Project / Project owner code field on the Work Order screen in QESTLab has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1574 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| On the following calibration worksheets for Balance (ID 30005), if Check Mass is greater than the largest load on the associated Balance Calibration Data Entry (ID 31010) worksheet then fields will now import from the reading with the largest load as long as Check Mass is within the specified Scale Range.&lt;br /&gt;
* Balance Single-Point Check [NATA Technical Note 13] (ID 31005)&lt;br /&gt;
* Balance Single-Point Check [NATA Technical Note 13 - 2014] (ID 31017)&lt;br /&gt;
* Balance Single-Point Check when Moving [NATA Technical Note 13] (ID 31008) &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1573 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A performance improvement has been made to the loading of work order data for QESTField Scheduler. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1572 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made to improve performance when loading technician data for the QESTField Scheduler.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1571 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made to improve performance when loading laboratory data for the QESTField Scheduler. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1568&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Old versions of windows label has been removed from splash screens.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1567 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The &amp;quot;Truck does not match&amp;quot; prompt in QESTField has been reworded.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1549 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| UI performance when editing user document configuration now scales a lot further when editing tables that have large numbers of columns. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1548 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following changes have been made for California Bearing Ratio tests in (10215,10222,10223,10224,10225,10226,10227,10228,10235,10237,10239,10592):&lt;br /&gt;
* The Raw Force value recorded at 0.0mm depth is now considered as a zero correction and is used to calculate all Force values.&lt;br /&gt;
* The zero offset will be copied to Seating values if no values are entered for Seating values.&lt;br /&gt;
* A new document level option is created to allow copying seating values to CBR Results tab as zero correction.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1547 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following for default format is now used for all user documents:&lt;br /&gt;
* Field Type, Default Format&lt;br /&gt;
* Integer, 0&lt;br /&gt;
* Decimal, 3sf&lt;br /&gt;
* Bit, List:True;Flase&lt;br /&gt;
* Money, 0.00&lt;br /&gt;
* Float, 3sf&lt;br /&gt;
* DateTime, Short Date&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1545 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Bulk publishing no longer produces corrupt PDFs due to multiple report types (e.g. Active Reports and PDFs) being passed in. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1544 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Specification Group names can now be up to 50 characters (previously set to 25) &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1543 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where lab-specific technicians could appear in dropdown selections when the Sampled By list (ID 20006) was set to &amp;quot;Global Only&amp;quot; has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1514 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The header &amp;quot;Compressive Strength of Concrete Cylinders Cast in Place in Cylindrical Molds&amp;quot; of CIP100 specimens in Concrete Test Reports is now corrected to refer &amp;quot;Cylindrical&amp;quot; instead of &amp;quot;Cylinderical&amp;quot;. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1479 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| For the following moisture content test screens, the field Nominal Aggregate Size (mm) has been replaced with the dropdown selection Maximum Particle Size to indicate the maximum sieve size with 100% material passing in accordance with standard ASTM D 2216.&lt;br /&gt;
* Water Content of Soil and Rock [ASTM D 2216] (ID 110060)&lt;br /&gt;
* Moisture Content of Soil and Rock [ASTM D 2216 - 2010] (ID 110066)&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1439 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where publishing an email to contacts with commas in their name could raise a &amp;quot;Subscript out of range&amp;quot; error. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1366 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where user document column names containing hyphens could not be deleted has been fixed.  These are now correctly enclosed in square brackets, and escaped if necessary. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1365 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The moisture content rounding of &amp;quot;oven-dried&amp;quot; moisture content is to nearest 0.1% for Moisture, Ash and Organic Content [ASTM D 2974 - 2007]. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1364 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where Density Offset Report (ID 17036) could not be loaded has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1363 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The test method no longer reports twice on the nuclear density report. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1362 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following can no longer appear in the Accredited Documents trees in the QEST Administrator Console, as they are not applicable:&lt;br /&gt;
* (ID 18010) Billing&lt;br /&gt;
* (ID 18015) Billing Summary&lt;br /&gt;
* (ID 18019) Invoice&lt;br /&gt;
* (ID 18020) Timekeeping&lt;br /&gt;
* (ID 18021) Timekeeping Records&lt;br /&gt;
* (ID 90022) Archived Test Report&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1361 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The bug where the Hanson &amp;quot;Concrete Test Delete Export&amp;quot; integrator was not being invoked correctly from QESTField/QESTNET has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1360 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Reports with NZGEO Custom Header now load without errors when the preliminary field value is null.&lt;br /&gt;
&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=QEST_Platform_4.5.2939&amp;diff=31380</id>
		<title>QEST Platform 4.5.2939</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=QEST_Platform_4.5.2939&amp;diff=31380"/>
		<updated>2018-01-18T03:27:32Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==QEST Platform 4.5.2939==&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
!Issue ID&lt;br /&gt;
!Release Notes&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1632&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug which caused some combo list selections to clear when a test screen was refreshed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1629 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QESTLab now runs on 32-bit systems again. Errors showing &amp;quot;Error 373: Failed to load from MSCOMCTL.OCX&amp;quot; are no longer seen.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1598 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| TRN will no longer be locked on applicable bulk entry views for Aggregate/Soil samples (ID 1001) and Asphalt samples (ID 1701). &lt;br /&gt;
Note that when TRN is changed on the Work Order the new value will replace the sample-level TRN.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1576 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where the user cannot click out of the Client / Project / Project owner code field on the Work Order screen in QESTLab has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1574 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| On the following calibration worksheets for Balance (ID 30005), if Check Mass is greater than the largest load on the associated Balance Calibration Data Entry (ID 31010) worksheet then fields will now import from the reading with the largest load as long as Check Mass is within the specified Scale Range.&lt;br /&gt;
* Balance Single-Point Check [NATA Technical Note 13] (ID 31005)&lt;br /&gt;
* Balance Single-Point Check [NATA Technical Note 13 - 2014] (ID 31017)&lt;br /&gt;
* Balance Single-Point Check when Moving [NATA Technical Note 13] (ID 31008) &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1573 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A performance improvement has been made to the loading of work order data for QESTField Scheduler. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1572 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made to improve performance when loading technician data for the QESTField Scheduler.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1571 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made to improve performance when loading laboratory data for the QESTField Scheduler. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1568&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Old versions of windows label has been removed from splash screens.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1567 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The &amp;quot;Truck does not match&amp;quot; prompt in QESTField has been reworded.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1549 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| UI performance when editing user document configuration now scales a lot further when editing tables that have large numbers of columns. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1548 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following changes have been made for California Bearing Ratio tests in (10215,10222,10223,10224,10225,10226,10227,10228,10235,10237,10239,10592):&lt;br /&gt;
* The Raw Force value recorded at 0.0mm depth is now considered as a zero correction and is used to calculate all Force values.&lt;br /&gt;
* The zero offset will be copied to Seating values if no values are entered for Seating values.&lt;br /&gt;
* A new document level option is created to allow copying seating values to CBR Results tab as zero correction.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1547 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following for default format is now used for all user documents:&lt;br /&gt;
* Field Type, Default Format&lt;br /&gt;
* Integer, 0&lt;br /&gt;
* Decimal, 3sf&lt;br /&gt;
* Bit, List:True;Flase&lt;br /&gt;
* Money, 0.00&lt;br /&gt;
* Float, 3sf&lt;br /&gt;
* DateTime, Short Date&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1545 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Bulk publishing no longer produces corrupt PDFs due to multiple report types (e.g. Active Reports and PDFs) being passed in. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1544 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Specification Group names can now be up to 50 characters (previously set to 25) &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1543 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where lab-specific technicians could appear in dropdown selections when the Sampled By list (ID 20006) was set to &amp;quot;Global Only&amp;quot; has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1514 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The header &amp;quot;Compressive Strength of Concrete Cylinders Cast in Place in Cylindrical Molds&amp;quot; of CIP100 specimens in Concrete Test Reports is now corrected to refer &amp;quot;Cylindrical&amp;quot; instead of &amp;quot;Cylinderical&amp;quot;. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1479 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| For the following moisture content test screens, the field Nominal Aggregate Size (mm) has been replaced with the dropdown selection Maximum Particle Size to indicate the maximum sieve size with 100% material passing in accordance with standard ASTM D 2216.&lt;br /&gt;
* Water Content of Soil and Rock [ASTM D 2216] (ID 110060)&lt;br /&gt;
* Moisture Content of Soil and Rock [ASTM D 2216 - 2010] (ID 110066)&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1439 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where publishing an email to contacts with commas in their name could raise a &amp;quot;Subscript out of range&amp;quot; error. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1366 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where user document column names containing hyphens could not be deleted has been fixed.  These are now correctly enclosed in square brackets, and escaped if necessary. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1365 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The moisture content rounding of &amp;quot;oven-dried&amp;quot; moisture content is to nearest 0.1% for Moisture, Ash and Organic Content [ASTM D 2974 - 2007]. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1364 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where Density Offset Report (ID 17036) could not be loaded has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1363 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The test method no longer reports twice on the nuclear density report. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1362 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following can no longer appear in the Accredited Documents trees in the QEST Administrator Console, as they are not applicable:&lt;br /&gt;
* (ID 18010) Billing&lt;br /&gt;
* (ID 18015) Billing Summary&lt;br /&gt;
* (ID 18019) Invoice&lt;br /&gt;
* (ID 18020) Timekeeping&lt;br /&gt;
* (ID 18021) Timekeeping Records&lt;br /&gt;
* (ID 90022) Archived Test Report&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1361 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The bug where the Hanson &amp;quot;Concrete Test Delete Export&amp;quot; integrator was not being invoked correctly from QESTField/QESTNET has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1360 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Reports with NZGEO Custom Header now load without errors when the preliminary field value is null.&lt;br /&gt;
&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=QEST_Platform_4.5.2939&amp;diff=31379</id>
		<title>QEST Platform 4.5.2939</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=QEST_Platform_4.5.2939&amp;diff=31379"/>
		<updated>2018-01-18T03:05:52Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==QEST Platform 4.5.2939==&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
!Issue ID&lt;br /&gt;
!Release Notes&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1632&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug which caused some combo list selections to clear when a test screen was refreshed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1629 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QESTLab now runs on 32-bit systems again. Errors showing &amp;quot;Error 373: Failed to load from MSCOMCTL.OCX&amp;quot; are no longer seen.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1598 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| TRN will no longer be locked on applicable bulk entry views for Aggregate/Soil samples (ID 1001) and Asphalt samples (ID 1701). &lt;br /&gt;
Note that when TRN is changed on the Work Order the new value will replace the sample-level TRN.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1576 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where the user cannot click out of the Client / Project / Project owner code field on the Work Order screen in QESTLab has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1574 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| On the following calibration worksheets for Balance (ID 30005), if Check Mass is greater than the largest load on the associated Balance Calibration Data Entry (ID 31010) worksheet then fields will now import from the reading with the largest load as long as Check Mass is within the specified Scale Range.&lt;br /&gt;
* Balance Single-Point Check [NATA Technical Note 13] (ID 31005)&lt;br /&gt;
* Balance Single-Point Check [NATA Technical Note 13 - 2014] (ID 31017)&lt;br /&gt;
* Balance Single-Point Check when Moving [NATA Technical Note 13] (ID 31008) &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1573 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A performance improvement has been made to the loading of work order data for QESTField Scheduler. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1572 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made to improve performance when loading technician data for the QESTField Scheduler.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1571 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made to improve performance when loading laboratory data for the QESTField Scheduler. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1568&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Old versions of windows label has been removed from splash screens.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1567 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The &amp;quot;Truck does not match&amp;quot; prompt in QESTField has been reworded.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1550 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue caused by certain company time zone settings that prevented new recipients from having documents distributed to them has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1549 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| UI performance when editing user document configuration now scales a lot further when editing tables that have large numbers of columns. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1548 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following changes have been made for California Bearing Ratio tests in (10215,10222,10223,10224,10225,10226,10227,10228,10235,10237,10239,10592):&lt;br /&gt;
* The Raw Force value recorded at 0.0mm depth is now considered as a zero correction and is used to calculate all Force values.&lt;br /&gt;
* The zero offset will be copied to Seating values if no values are entered for Seating values.&lt;br /&gt;
* A new document level option is created to allow copying seating values to CBR Results tab as zero correction.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1547 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following for default format is now used for all user documents:&lt;br /&gt;
* Field Type, Default Format&lt;br /&gt;
* Integer, 0&lt;br /&gt;
* Decimal, 3sf&lt;br /&gt;
* Bit, List:True;Flase&lt;br /&gt;
* Money, 0.00&lt;br /&gt;
* Float, 3sf&lt;br /&gt;
* DateTime, Short Date&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1546 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Construction Hive now prevents notifications in silent publishing for reports with existing non-silent revisions. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1545 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Bulk publishing no longer produces corrupt PDFs due to multiple report types (e.g. Active Reports and PDFs) being passed in. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1544 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Specification Group names can now be up to 50 characters (previously set to 25) &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1543 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where lab-specific technicians could appear in dropdown selections when the Sampled By list (ID 20006) was set to &amp;quot;Global Only&amp;quot; has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1514 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The header &amp;quot;Compressive Strength of Concrete Cylinders Cast in Place in Cylindrical Molds&amp;quot; of CIP100 specimens in Concrete Test Reports is now corrected to refer &amp;quot;Cylindrical&amp;quot; instead of &amp;quot;Cylinderical&amp;quot;. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1479 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| For the following moisture content test screens, the field Nominal Aggregate Size (mm) has been replaced with the dropdown selection Maximum Particle Size to indicate the maximum sieve size with 100% material passing in accordance with standard ASTM D 2216.&lt;br /&gt;
* Water Content of Soil and Rock [ASTM D 2216] (ID 110060)&lt;br /&gt;
* Moisture Content of Soil and Rock [ASTM D 2216 - 2010] (ID 110066)&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1439 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where publishing an email to contacts with commas in their name could raise a &amp;quot;Subscript out of range&amp;quot; error. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1368 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| When publishing a document the distribution list is still populated when a deleted user is a member of the project. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1367 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| This change attempts to resolve an occasional error that occurred during publishing, &amp;quot;Error while publishing binary: Error -2147024882: Not enough storage is available to complete this operation&amp;quot;. It also adds further detail to error messages in this area to help identify the location where the error occurs. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1366 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where user document column names containing hyphens could not be deleted has been fixed.  These are now correctly enclosed in square brackets, and escaped if necessary. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1365 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The moisture content rounding of &amp;quot;oven-dried&amp;quot; moisture content is to nearest 0.1% for Moisture, Ash and Organic Content [ASTM D 2974 - 2007]. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1364 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where Density Offset Report (ID 17036) could not be loaded has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1363 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The test method no longer reports twice on the nuclear density report. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1362 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following can no longer appear in the Accredited Documents trees in the QEST Administrator Console, as they are not applicable:&lt;br /&gt;
* (ID 18010) Billing&lt;br /&gt;
* (ID 18015) Billing Summary&lt;br /&gt;
* (ID 18019) Invoice&lt;br /&gt;
* (ID 18020) Timekeeping&lt;br /&gt;
* (ID 18021) Timekeeping Records&lt;br /&gt;
* (ID 90022) Archived Test Report&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1361 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The bug where the Hanson &amp;quot;Concrete Test Delete Export&amp;quot; integrator was not being invoked correctly from QESTField/QESTNET has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1360 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Reports with NZGEO Custom Header now load without errors when the preliminary field value is null.&lt;br /&gt;
&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=Template:QEST_Platform_4.5.2939&amp;diff=31378</id>
		<title>Template:QEST Platform 4.5.2939</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=Template:QEST_Platform_4.5.2939&amp;diff=31378"/>
		<updated>2018-01-18T03:05:38Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==QEST Platform 4.5.2939==&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
!Issue ID&lt;br /&gt;
!Release Notes&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1632&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug which caused some combo list selections to clear when a test screen was refreshed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1629 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QESTLab now runs on 32-bit systems again. Errors showing &amp;quot;Error 373: Failed to load from MSCOMCTL.OCX&amp;quot; are no longer seen.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1598 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| TRN will no longer be locked on applicable bulk entry views for Aggregate/Soil samples (ID 1001) and Asphalt samples (ID 1701). &lt;br /&gt;
Note that when TRN is changed on the Work Order the new value will replace the sample-level TRN.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1576 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where the user cannot click out of the Client / Project / Project owner code field on the Work Order screen in QESTLab has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1574 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| On the following calibration worksheets for Balance (ID 30005), if Check Mass is greater than the largest load on the associated Balance Calibration Data Entry (ID 31010) worksheet then fields will now import from the reading with the largest load as long as Check Mass is within the specified Scale Range.&lt;br /&gt;
* Balance Single-Point Check [NATA Technical Note 13] (ID 31005)&lt;br /&gt;
* Balance Single-Point Check [NATA Technical Note 13 - 2014] (ID 31017)&lt;br /&gt;
* Balance Single-Point Check when Moving [NATA Technical Note 13] (ID 31008) &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1573 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A performance improvement has been made to the loading of work order data for QESTField Scheduler. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1572 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made to improve performance when loading technician data for the QESTField Scheduler.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1571 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made to improve performance when loading laboratory data for the QESTField Scheduler. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1568&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Old versions of windows label has been removed from splash screens.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1567 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The &amp;quot;Truck does not match&amp;quot; prompt in QESTField has been reworded.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1550 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue caused by certain company time zone settings that prevented new recipients from having documents distributed to them has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1549 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| UI performance when editing user document configuration now scales a lot further when editing tables that have large numbers of columns. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1548 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following changes have been made for California Bearing Ratio tests in (10215,10222,10223,10224,10225,10226,10227,10228,10235,10237,10239,10592):&lt;br /&gt;
* The Raw Force value recorded at 0.0mm depth is now considered as a zero correction and is used to calculate all Force values.&lt;br /&gt;
* The zero offset will be copied to Seating values if no values are entered for Seating values.&lt;br /&gt;
* A new document level option is created to allow copying seating values to CBR Results tab as zero correction.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1547 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following for default format is now used for all user documents:&lt;br /&gt;
* Field Type, Default Format&lt;br /&gt;
* Integer, 0&lt;br /&gt;
* Decimal, 3sf&lt;br /&gt;
* Bit, List:True;Flase&lt;br /&gt;
* Money, 0.00&lt;br /&gt;
* Float, 3sf&lt;br /&gt;
* DateTime, Short Date&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1546 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Construction Hive now prevents notifications in silent publishing for reports with existing non-silent revisions. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1545 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Bulk publishing no longer produces corrupt PDFs due to multiple report types (e.g. Active Reports and PDFs) being passed in. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1544 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Specification Group names can now be up to 50 characters (previously set to 25) &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1543 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where lab-specific technicians could appear in dropdown selections when the Sampled By list (ID 20006) was set to &amp;quot;Global Only&amp;quot; has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1514 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The header &amp;quot;Compressive Strength of Concrete Cylinders Cast in Place in Cylindrical Molds&amp;quot; of CIP100 specimens in Concrete Test Reports is now corrected to refer &amp;quot;Cylindrical&amp;quot; instead of &amp;quot;Cylinderical&amp;quot;. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1479 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| For the following moisture content test screens, the field Nominal Aggregate Size (mm) has been replaced with the dropdown selection Maximum Particle Size to indicate the maximum sieve size with 100% material passing in accordance with standard ASTM D 2216.&lt;br /&gt;
* Water Content of Soil and Rock [ASTM D 2216] (ID 110060)&lt;br /&gt;
* Moisture Content of Soil and Rock [ASTM D 2216 - 2010] (ID 110066)&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1439 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where publishing an email to contacts with commas in their name could raise a &amp;quot;Subscript out of range&amp;quot; error. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1368 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| When publishing a document the distribution list is still populated when a deleted user is a member of the project. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1367 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| This change attempts to resolve an occasional error that occurred during publishing, &amp;quot;Error while publishing binary: Error -2147024882: Not enough storage is available to complete this operation&amp;quot;. It also adds further detail to error messages in this area to help identify the location where the error occurs. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1366 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where user document column names containing hyphens could not be deleted has been fixed.  These are now correctly enclosed in square brackets, and escaped if necessary. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1365 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The moisture content rounding of &amp;quot;oven-dried&amp;quot; moisture content is to nearest 0.1% for Moisture, Ash and Organic Content [ASTM D 2974 - 2007]. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1364 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where Density Offset Report (ID 17036) could not be loaded has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1363 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The test method no longer reports twice on the nuclear density report. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1362 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following can no longer appear in the Accredited Documents trees in the QEST Administrator Console, as they are not applicable:&lt;br /&gt;
* (ID 18010) Billing&lt;br /&gt;
* (ID 18015) Billing Summary&lt;br /&gt;
* (ID 18019) Invoice&lt;br /&gt;
* (ID 18020) Timekeeping&lt;br /&gt;
* (ID 18021) Timekeeping Records&lt;br /&gt;
* (ID 90022) Archived Test Report&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1361 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The bug where the Hanson &amp;quot;Concrete Test Delete Export&amp;quot; integrator was not being invoked correctly from QESTField/QESTNET has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1360 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Reports with NZGEO Custom Header now load without errors when the preliminary field value is null.&lt;br /&gt;
&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=Template:QEST_Platform_4.5.2939&amp;diff=31377</id>
		<title>Template:QEST Platform 4.5.2939</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=Template:QEST_Platform_4.5.2939&amp;diff=31377"/>
		<updated>2018-01-18T03:05:28Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==QEST Platform 4.5.2939==&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
!Bug/CR ID&lt;br /&gt;
!Release Notes&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1632&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug which caused some combo list selections to clear when a test screen was refreshed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1629 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QESTLab now runs on 32-bit systems again. Errors showing &amp;quot;Error 373: Failed to load from MSCOMCTL.OCX&amp;quot; are no longer seen.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1598 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| TRN will no longer be locked on applicable bulk entry views for Aggregate/Soil samples (ID 1001) and Asphalt samples (ID 1701). &lt;br /&gt;
Note that when TRN is changed on the Work Order the new value will replace the sample-level TRN.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1576 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where the user cannot click out of the Client / Project / Project owner code field on the Work Order screen in QESTLab has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1574 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| On the following calibration worksheets for Balance (ID 30005), if Check Mass is greater than the largest load on the associated Balance Calibration Data Entry (ID 31010) worksheet then fields will now import from the reading with the largest load as long as Check Mass is within the specified Scale Range.&lt;br /&gt;
* Balance Single-Point Check [NATA Technical Note 13] (ID 31005)&lt;br /&gt;
* Balance Single-Point Check [NATA Technical Note 13 - 2014] (ID 31017)&lt;br /&gt;
* Balance Single-Point Check when Moving [NATA Technical Note 13] (ID 31008) &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1573 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A performance improvement has been made to the loading of work order data for QESTField Scheduler. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1572 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made to improve performance when loading technician data for the QESTField Scheduler.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1571 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made to improve performance when loading laboratory data for the QESTField Scheduler. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1568&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Old versions of windows label has been removed from splash screens.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1567 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The &amp;quot;Truck does not match&amp;quot; prompt in QESTField has been reworded.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1550 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue caused by certain company time zone settings that prevented new recipients from having documents distributed to them has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1549 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| UI performance when editing user document configuration now scales a lot further when editing tables that have large numbers of columns. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1548 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following changes have been made for California Bearing Ratio tests in (10215,10222,10223,10224,10225,10226,10227,10228,10235,10237,10239,10592):&lt;br /&gt;
* The Raw Force value recorded at 0.0mm depth is now considered as a zero correction and is used to calculate all Force values.&lt;br /&gt;
* The zero offset will be copied to Seating values if no values are entered for Seating values.&lt;br /&gt;
* A new document level option is created to allow copying seating values to CBR Results tab as zero correction.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1547 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following for default format is now used for all user documents:&lt;br /&gt;
* Field Type, Default Format&lt;br /&gt;
* Integer, 0&lt;br /&gt;
* Decimal, 3sf&lt;br /&gt;
* Bit, List:True;Flase&lt;br /&gt;
* Money, 0.00&lt;br /&gt;
* Float, 3sf&lt;br /&gt;
* DateTime, Short Date&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1546 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Construction Hive now prevents notifications in silent publishing for reports with existing non-silent revisions. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1545 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Bulk publishing no longer produces corrupt PDFs due to multiple report types (e.g. Active Reports and PDFs) being passed in. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1544 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Specification Group names can now be up to 50 characters (previously set to 25) &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1543 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where lab-specific technicians could appear in dropdown selections when the Sampled By list (ID 20006) was set to &amp;quot;Global Only&amp;quot; has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1514 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The header &amp;quot;Compressive Strength of Concrete Cylinders Cast in Place in Cylindrical Molds&amp;quot; of CIP100 specimens in Concrete Test Reports is now corrected to refer &amp;quot;Cylindrical&amp;quot; instead of &amp;quot;Cylinderical&amp;quot;. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1479 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| For the following moisture content test screens, the field Nominal Aggregate Size (mm) has been replaced with the dropdown selection Maximum Particle Size to indicate the maximum sieve size with 100% material passing in accordance with standard ASTM D 2216.&lt;br /&gt;
* Water Content of Soil and Rock [ASTM D 2216] (ID 110060)&lt;br /&gt;
* Moisture Content of Soil and Rock [ASTM D 2216 - 2010] (ID 110066)&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1439 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where publishing an email to contacts with commas in their name could raise a &amp;quot;Subscript out of range&amp;quot; error. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1368 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| When publishing a document the distribution list is still populated when a deleted user is a member of the project. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1367 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| This change attempts to resolve an occasional error that occurred during publishing, &amp;quot;Error while publishing binary: Error -2147024882: Not enough storage is available to complete this operation&amp;quot;. It also adds further detail to error messages in this area to help identify the location where the error occurs. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1366 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where user document column names containing hyphens could not be deleted has been fixed.  These are now correctly enclosed in square brackets, and escaped if necessary. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1365 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The moisture content rounding of &amp;quot;oven-dried&amp;quot; moisture content is to nearest 0.1% for Moisture, Ash and Organic Content [ASTM D 2974 - 2007]. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1364 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where Density Offset Report (ID 17036) could not be loaded has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1363 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The test method no longer reports twice on the nuclear density report. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1362 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following can no longer appear in the Accredited Documents trees in the QEST Administrator Console, as they are not applicable:&lt;br /&gt;
* (ID 18010) Billing&lt;br /&gt;
* (ID 18015) Billing Summary&lt;br /&gt;
* (ID 18019) Invoice&lt;br /&gt;
* (ID 18020) Timekeeping&lt;br /&gt;
* (ID 18021) Timekeeping Records&lt;br /&gt;
* (ID 90022) Archived Test Report&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1361 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The bug where the Hanson &amp;quot;Concrete Test Delete Export&amp;quot; integrator was not being invoked correctly from QESTField/QESTNET has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1360 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Reports with NZGEO Custom Header now load without errors when the preliminary field value is null.&lt;br /&gt;
&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=QEST_Platform_4.5.2939&amp;diff=31376</id>
		<title>QEST Platform 4.5.2939</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=QEST_Platform_4.5.2939&amp;diff=31376"/>
		<updated>2018-01-18T03:05:15Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==QEST Platform 4.5.2939==&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
!Bug/CR ID&lt;br /&gt;
!Release Notes&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1632&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug which caused some combo list selections to clear when a test screen was refreshed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1629 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QESTLab now runs on 32-bit systems again. Errors showing &amp;quot;Error 373: Failed to load from MSCOMCTL.OCX&amp;quot; are no longer seen.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1598 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| TRN will no longer be locked on applicable bulk entry views for Aggregate/Soil samples (ID 1001) and Asphalt samples (ID 1701). &lt;br /&gt;
Note that when TRN is changed on the Work Order the new value will replace the sample-level TRN.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1576 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where the user cannot click out of the Client / Project / Project owner code field on the Work Order screen in QESTLab has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1574 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| On the following calibration worksheets for Balance (ID 30005), if Check Mass is greater than the largest load on the associated Balance Calibration Data Entry (ID 31010) worksheet then fields will now import from the reading with the largest load as long as Check Mass is within the specified Scale Range.&lt;br /&gt;
* Balance Single-Point Check [NATA Technical Note 13] (ID 31005)&lt;br /&gt;
* Balance Single-Point Check [NATA Technical Note 13 - 2014] (ID 31017)&lt;br /&gt;
* Balance Single-Point Check when Moving [NATA Technical Note 13] (ID 31008) &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1573 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A performance improvement has been made to the loading of work order data for QESTField Scheduler. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1572 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made to improve performance when loading technician data for the QESTField Scheduler.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1571 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made to improve performance when loading laboratory data for the QESTField Scheduler. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1568&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Old versions of windows label has been removed from splash screens.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1567 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The &amp;quot;Truck does not match&amp;quot; prompt in QESTField has been reworded.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1550 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue caused by certain company time zone settings that prevented new recipients from having documents distributed to them has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1549 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| UI performance when editing user document configuration now scales a lot further when editing tables that have large numbers of columns. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1548 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following changes have been made for California Bearing Ratio tests in (10215,10222,10223,10224,10225,10226,10227,10228,10235,10237,10239,10592):&lt;br /&gt;
* The Raw Force value recorded at 0.0mm depth is now considered as a zero correction and is used to calculate all Force values.&lt;br /&gt;
* The zero offset will be copied to Seating values if no values are entered for Seating values.&lt;br /&gt;
* A new document level option is created to allow copying seating values to CBR Results tab as zero correction.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1547 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following for default format is now used for all user documents:&lt;br /&gt;
* Field Type, Default Format&lt;br /&gt;
* Integer, 0&lt;br /&gt;
* Decimal, 3sf&lt;br /&gt;
* Bit, List:True;Flase&lt;br /&gt;
* Money, 0.00&lt;br /&gt;
* Float, 3sf&lt;br /&gt;
* DateTime, Short Date&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1546 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Construction Hive now prevents notifications in silent publishing for reports with existing non-silent revisions. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1545 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Bulk publishing no longer produces corrupt PDFs due to multiple report types (e.g. Active Reports and PDFs) being passed in. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1544 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Specification Group names can now be up to 50 characters (previously set to 25) &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1543 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where lab-specific technicians could appear in dropdown selections when the Sampled By list (ID 20006) was set to &amp;quot;Global Only&amp;quot; has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1514 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The header &amp;quot;Compressive Strength of Concrete Cylinders Cast in Place in Cylindrical Molds&amp;quot; of CIP100 specimens in Concrete Test Reports is now corrected to refer &amp;quot;Cylindrical&amp;quot; instead of &amp;quot;Cylinderical&amp;quot;. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1479 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| For the following moisture content test screens, the field Nominal Aggregate Size (mm) has been replaced with the dropdown selection Maximum Particle Size to indicate the maximum sieve size with 100% material passing in accordance with standard ASTM D 2216.&lt;br /&gt;
* Water Content of Soil and Rock [ASTM D 2216] (ID 110060)&lt;br /&gt;
* Moisture Content of Soil and Rock [ASTM D 2216 - 2010] (ID 110066)&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1439 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where publishing an email to contacts with commas in their name could raise a &amp;quot;Subscript out of range&amp;quot; error. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1368 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| When publishing a document the distribution list is still populated when a deleted user is a member of the project. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1367 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| This change attempts to resolve an occasional error that occurred during publishing, &amp;quot;Error while publishing binary: Error -2147024882: Not enough storage is available to complete this operation&amp;quot;. It also adds further detail to error messages in this area to help identify the location where the error occurs. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1366 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where user document column names containing hyphens could not be deleted has been fixed.  These are now correctly enclosed in square brackets, and escaped if necessary. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1365 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The moisture content rounding of &amp;quot;oven-dried&amp;quot; moisture content is to nearest 0.1% for Moisture, Ash and Organic Content [ASTM D 2974 - 2007]. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1364 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where Density Offset Report (ID 17036) could not be loaded has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1363 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The test method no longer reports twice on the nuclear density report. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1362 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following can no longer appear in the Accredited Documents trees in the QEST Administrator Console, as they are not applicable:&lt;br /&gt;
* (ID 18010) Billing&lt;br /&gt;
* (ID 18015) Billing Summary&lt;br /&gt;
* (ID 18019) Invoice&lt;br /&gt;
* (ID 18020) Timekeeping&lt;br /&gt;
* (ID 18021) Timekeeping Records&lt;br /&gt;
* (ID 90022) Archived Test Report&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1361 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The bug where the Hanson &amp;quot;Concrete Test Delete Export&amp;quot; integrator was not being invoked correctly from QESTField/QESTNET has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1360 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Reports with NZGEO Custom Header now load without errors when the preliminary field value is null.&lt;br /&gt;
&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=Template:QEST_Platform_4.5.2939&amp;diff=31374</id>
		<title>Template:QEST Platform 4.5.2939</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=Template:QEST_Platform_4.5.2939&amp;diff=31374"/>
		<updated>2018-01-18T02:05:47Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==QEST Platform 4.5.2939==&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
!Bug/CR ID&lt;br /&gt;
!Customer Code&lt;br /&gt;
!Release Notes&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1632&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug which caused some combo list selections to clear when a test screen was refreshed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1629 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QESTLab now runs on 32-bit systems again. Errors showing &amp;quot;Error 373: Failed to load from MSCOMCTL.OCX&amp;quot; are no longer seen.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1598 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| MEFUG&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| TRN will no longer be locked on applicable bulk entry views for Aggregate/Soil samples (ID 1001) and Asphalt samples (ID 1701). &lt;br /&gt;
Note that when TRN is changed on the Work Order the new value will replace the sample-level TRN.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1576 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where the user cannot click out of the Client / Project / Project owner code field on the Work Order screen in QESTLab has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1574 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| AUVIC &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| On the following calibration worksheets for Balance (ID 30005), if Check Mass is greater than the largest load on the associated Balance Calibration Data Entry (ID 31010) worksheet then fields will now import from the reading with the largest load as long as Check Mass is within the specified Scale Range.&lt;br /&gt;
* Balance Single-Point Check [NATA Technical Note 13] (ID 31005)&lt;br /&gt;
* Balance Single-Point Check [NATA Technical Note 13 - 2014] (ID 31017)&lt;br /&gt;
* Balance Single-Point Check when Moving [NATA Technical Note 13] (ID 31008) &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1573 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| USTWI&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A performance improvement has been made to the loading of work order data for QESTField Scheduler. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1572 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| USTWI&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made to improve performance when loading technician data for the QESTField Scheduler.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1571 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| USTWI&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made to improve performance when loading laboratory data for the QESTField Scheduler. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1568&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| NZFUH&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Old versions of windows label has been removed from splash screens.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1567 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| AUHAN&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The &amp;quot;Truck does not match&amp;quot; prompt in QESTField has been reworded.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1550 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| MEFUG&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue caused by certain company time zone settings that prevented new recipients from having documents distributed to them has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1549 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| AUHAN&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| UI performance when editing user document configuration now scales a lot further when editing tables that have large numbers of columns. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1548 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following changes have been made for California Bearing Ratio tests in (10215,10222,10223,10224,10225,10226,10227,10228,10235,10237,10239,10592):&lt;br /&gt;
* The Raw Force value recorded at 0.0mm depth is now considered as a zero correction and is used to calculate all Force values.&lt;br /&gt;
* The zero offset will be copied to Seating values if no values are entered for Seating values.&lt;br /&gt;
* A new document level option is created to allow copying seating values to CBR Results tab as zero correction.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1547 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following for default format is now used for all user documents:&lt;br /&gt;
* Field Type, Default Format&lt;br /&gt;
* Integer, 0&lt;br /&gt;
* Decimal, 3sf&lt;br /&gt;
* Bit, List:True;Flase&lt;br /&gt;
* Money, 0.00&lt;br /&gt;
* Float, 3sf&lt;br /&gt;
* DateTime, Short Date&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1546 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|  &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Construction Hive now prevents notifications in silent publishing for reports with existing non-silent revisions. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1545 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| AUCHA &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Bulk publishing no longer produces corrupt PDFs due to multiple report types (e.g. Active Reports and PDFs) being passed in. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1544 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|  &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Specification Group names can now be up to 50 characters (previously set to 25) &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1543 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|  &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where lab-specific technicians could appear in dropdown selections when the Sampled By list (ID 20006) was set to &amp;quot;Global Only&amp;quot; has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1514 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| USPSI &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The header &amp;quot;Compressive Strength of Concrete Cylinders Cast in Place in Cylindrical Molds&amp;quot; of CIP100 specimens in Concrete Test Reports is now corrected to refer &amp;quot;Cylindrical&amp;quot; instead of &amp;quot;Cylinderical&amp;quot;. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1479 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|  &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| For the following moisture content test screens, the field Nominal Aggregate Size (mm) has been replaced with the dropdown selection Maximum Particle Size to indicate the maximum sieve size with 100% material passing in accordance with standard ASTM D 2216.&lt;br /&gt;
* Water Content of Soil and Rock [ASTM D 2216] (ID 110060)&lt;br /&gt;
* Moisture Content of Soil and Rock [ASTM D 2216 - 2010] (ID 110066)&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1439 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| USHVJ &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where publishing an email to contacts with commas in their name could raise a &amp;quot;Subscript out of range&amp;quot; error. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1368 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| USTWI &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| When publishing a document the distribution list is still populated when a deleted user is a member of the project. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1367 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| USTWI &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| This change attempts to resolve an occasional error that occurred during publishing, &amp;quot;Error while publishing binary: Error -2147024882: Not enough storage is available to complete this operation&amp;quot;. It also adds further detail to error messages in this area to help identify the location where the error occurs. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1366 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|  &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where user document column names containing hyphens could not be deleted has been fixed.  These are now correctly enclosed in square brackets, and escaped if necessary. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1365 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| USWSB &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The moisture content rounding of &amp;quot;oven-dried&amp;quot; moisture content is to nearest 0.1% for Moisture, Ash and Organic Content [ASTM D 2974 - 2007]. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1364 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| AUDEW&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where Density Offset Report (ID 17036) could not be loaded has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1363 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| NZGEO&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The test method no longer reports twice on the nuclear density report. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1362 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| USPSI&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following can no longer appear in the Accredited Documents trees in the QEST Administrator Console, as they are not applicable:&lt;br /&gt;
* (ID 18010) Billing&lt;br /&gt;
* (ID 18015) Billing Summary&lt;br /&gt;
* (ID 18019) Invoice&lt;br /&gt;
* (ID 18020) Timekeeping&lt;br /&gt;
* (ID 18021) Timekeeping Records&lt;br /&gt;
* (ID 90022) Archived Test Report&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1361 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|  &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The bug where the Hanson &amp;quot;Concrete Test Delete Export&amp;quot; integrator was not being invoked correctly from QESTField/QESTNET has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1360 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| NZGEO &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Reports with NZGEO Custom Header now load without errors when the preliminary field value is null.&lt;br /&gt;
&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=Template:QEST_Platform_4.5.2939&amp;diff=31373</id>
		<title>Template:QEST Platform 4.5.2939</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=Template:QEST_Platform_4.5.2939&amp;diff=31373"/>
		<updated>2018-01-18T02:05:17Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=Template:QEST_Platform_4.5.2939&amp;diff=31372</id>
		<title>Template:QEST Platform 4.5.2939</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=Template:QEST_Platform_4.5.2939&amp;diff=31372"/>
		<updated>2018-01-18T02:05:06Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Test&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=QEST_Platform_4.5.2939&amp;diff=31370</id>
		<title>QEST Platform 4.5.2939</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=QEST_Platform_4.5.2939&amp;diff=31370"/>
		<updated>2018-01-18T02:01:31Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==QEST Platform 4.5.2939==&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
!Bug/CR ID&lt;br /&gt;
!Customer Code&lt;br /&gt;
!Release Notes&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1632&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug which caused some combo list selections to clear when a test screen was refreshed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1629 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QESTLab now runs on 32-bit systems again. Errors showing &amp;quot;Error 373: Failed to load from MSCOMCTL.OCX&amp;quot; are no longer seen.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1598 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| MEFUG&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| TRN will no longer be locked on applicable bulk entry views for Aggregate/Soil samples (ID 1001) and Asphalt samples (ID 1701). &lt;br /&gt;
Note that when TRN is changed on the Work Order the new value will replace the sample-level TRN.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1576 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where the user cannot click out of the Client / Project / Project owner code field on the Work Order screen in QESTLab has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1574 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| AUVIC &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| On the following calibration worksheets for Balance (ID 30005), if Check Mass is greater than the largest load on the associated Balance Calibration Data Entry (ID 31010) worksheet then fields will now import from the reading with the largest load as long as Check Mass is within the specified Scale Range.&lt;br /&gt;
* Balance Single-Point Check [NATA Technical Note 13] (ID 31005)&lt;br /&gt;
* Balance Single-Point Check [NATA Technical Note 13 - 2014] (ID 31017)&lt;br /&gt;
* Balance Single-Point Check when Moving [NATA Technical Note 13] (ID 31008) &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1573 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| USTWI&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A performance improvement has been made to the loading of work order data for QESTField Scheduler. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1572 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| USTWI&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made to improve performance when loading technician data for the QESTField Scheduler.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1571 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| USTWI&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made to improve performance when loading laboratory data for the QESTField Scheduler. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1568&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| NZFUH&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Old versions of windows label has been removed from splash screens.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1567 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| AUHAN&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The &amp;quot;Truck does not match&amp;quot; prompt in QESTField has been reworded.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1550 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| MEFUG&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue caused by certain company time zone settings that prevented new recipients from having documents distributed to them has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1549 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| AUHAN&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| UI performance when editing user document configuration now scales a lot further when editing tables that have large numbers of columns. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1548 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following changes have been made for California Bearing Ratio tests in (10215,10222,10223,10224,10225,10226,10227,10228,10235,10237,10239,10592):&lt;br /&gt;
* The Raw Force value recorded at 0.0mm depth is now considered as a zero correction and is used to calculate all Force values.&lt;br /&gt;
* The zero offset will be copied to Seating values if no values are entered for Seating values.&lt;br /&gt;
* A new document level option is created to allow copying seating values to CBR Results tab as zero correction.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1547 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following for default format is now used for all user documents:&lt;br /&gt;
* Field Type, Default Format&lt;br /&gt;
* Integer, 0&lt;br /&gt;
* Decimal, 3sf&lt;br /&gt;
* Bit, List:True;Flase&lt;br /&gt;
* Money, 0.00&lt;br /&gt;
* Float, 3sf&lt;br /&gt;
* DateTime, Short Date&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1546 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|  &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Construction Hive now prevents notifications in silent publishing for reports with existing non-silent revisions. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1545 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| AUCHA &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Bulk publishing no longer produces corrupt PDFs due to multiple report types (e.g. Active Reports and PDFs) being passed in. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1544 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|  &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Specification Group names can now be up to 50 characters (previously set to 25) &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1543 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|  &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where lab-specific technicians could appear in dropdown selections when the Sampled By list (ID 20006) was set to &amp;quot;Global Only&amp;quot; has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1514 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| USPSI &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The header &amp;quot;Compressive Strength of Concrete Cylinders Cast in Place in Cylindrical Molds&amp;quot; of CIP100 specimens in Concrete Test Reports is now corrected to refer &amp;quot;Cylindrical&amp;quot; instead of &amp;quot;Cylinderical&amp;quot;. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1479 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|  &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| For the following moisture content test screens, the field Nominal Aggregate Size (mm) has been replaced with the dropdown selection Maximum Particle Size to indicate the maximum sieve size with 100% material passing in accordance with standard ASTM D 2216.&lt;br /&gt;
* Water Content of Soil and Rock [ASTM D 2216] (ID 110060)&lt;br /&gt;
* Moisture Content of Soil and Rock [ASTM D 2216 - 2010] (ID 110066)&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1439 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| USHVJ &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where publishing an email to contacts with commas in their name could raise a &amp;quot;Subscript out of range&amp;quot; error. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1368 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| USTWI &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| When publishing a document the distribution list is still populated when a deleted user is a member of the project. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1367 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| USTWI &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| This change attempts to resolve an occasional error that occurred during publishing, &amp;quot;Error while publishing binary: Error -2147024882: Not enough storage is available to complete this operation&amp;quot;. It also adds further detail to error messages in this area to help identify the location where the error occurs. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1366 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|  &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where user document column names containing hyphens could not be deleted has been fixed.  These are now correctly enclosed in square brackets, and escaped if necessary. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1365 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| USWSB &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The moisture content rounding of &amp;quot;oven-dried&amp;quot; moisture content is to nearest 0.1% for Moisture, Ash and Organic Content [ASTM D 2974 - 2007]. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1364 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| AUDEW&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where Density Offset Report (ID 17036) could not be loaded has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1363 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| NZGEO&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The test method no longer reports twice on the nuclear density report. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1362 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| USPSI&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following can no longer appear in the Accredited Documents trees in the QEST Administrator Console, as they are not applicable:&lt;br /&gt;
* (ID 18010) Billing&lt;br /&gt;
* (ID 18015) Billing Summary&lt;br /&gt;
* (ID 18019) Invoice&lt;br /&gt;
* (ID 18020) Timekeeping&lt;br /&gt;
* (ID 18021) Timekeeping Records&lt;br /&gt;
* (ID 90022) Archived Test Report&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1361 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|  &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The bug where the Hanson &amp;quot;Concrete Test Delete Export&amp;quot; integrator was not being invoked correctly from QESTField/QESTNET has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1360 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| NZGEO &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Reports with NZGEO Custom Header now load without errors when the preliminary field value is null.&lt;br /&gt;
&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=QEST_Platform_4.5.2939&amp;diff=31369</id>
		<title>QEST Platform 4.5.2939</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=QEST_Platform_4.5.2939&amp;diff=31369"/>
		<updated>2018-01-18T01:57:14Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==QEST Platform 4.5.2939==&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
!Bug/CR ID&lt;br /&gt;
!Customer Code&lt;br /&gt;
!Release Notes&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1632&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed a bug which caused some combo list selections to clear when a test screen was refreshed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1629 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QESTLab now runs on 32-bit systems again. Errors showing &amp;quot;Error 373: Failed to load from MSCOMCTL.OCX&amp;quot; are no longer seen.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1598 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| MEFUG&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| TRN will no longer be locked on applicable bulk entry views for Aggregate/Soil samples (ID 1001) and Asphalt samples (ID 1701). &lt;br /&gt;
Note that when TRN is changed on the Work Order the new value will replace the sample-level TRN.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1576 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where the user cannot click out of the Client / Project / Project owner code field on the Work Order screen in QESTLab has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1574 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| AUVIC &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| On the following calibration worksheets for Balance (ID 30005), if Check Mass is greater than the largest load on the associated Balance Calibration Data Entry (ID 31010) worksheet then fields will now import from the reading with the largest load as long as Check Mass is within the specified Scale Range.&lt;br /&gt;
* Balance Single-Point Check \[NATA Technical Note 13] (ID 31005)&lt;br /&gt;
* Balance Single-Point Check \[NATA Technical Note 13 - 2014] (ID 31017)&lt;br /&gt;
* Balance Single-Point Check when Moving \[NATA Technical Note 13] (ID 31008) &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1573 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| USTWI&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A performance improvement has been made to the loading of work order data for QESTField Scheduler. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1572 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| USTWI&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made to improve performance when loading technician data for the QESTField Scheduler.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1571 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| USTWI&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A change has been made to improve performance when loading laboratory data for the QESTField Scheduler. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1568 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| NZFUH&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Old versions of windows label is removed from Splash screen. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1567 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| AUHAN&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The &amp;quot;Truck does not match&amp;quot; prompt in QESTField has been reworded.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1550 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| MEFUG&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue caused by certain company time zone settings that prevented new recipients from having documents distributed to them has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1549 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| AUHAN&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| UI Performance when editing user document configuration now scales a lot further when editing tables that have large numbers of columns. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1548 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following changes have been made for California Bearing Ratio tests in (10215,10222,10223,10224,10225,10226,10227,10228,10235,10237,10239,10592):&lt;br /&gt;
* The Raw Force value recorded at 0.0mm depth is now considered as a zero correction and is used to calculate all Force values.&lt;br /&gt;
* The zero offset will be copied to Seating values if no values are entered for Seating values.&lt;br /&gt;
* A new document level option is created to allow copying seating values to CBR Results tab as zero correction.&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1547 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following for default format is now used for all user documents:&lt;br /&gt;
* Field Type, Default Format&lt;br /&gt;
* Integer, 0&lt;br /&gt;
* Decimal, 3sf&lt;br /&gt;
* Bit, List:True;Flase&lt;br /&gt;
* Money, 0.00&lt;br /&gt;
* Float, 3sf&lt;br /&gt;
* DateTime, Short Date&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1546 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|  &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Construction Hive now prevents notifications in silent publishing for reports with existing non-silent revisions. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1545 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| AUCHA &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Bulk publishing no longer produces corrupt PDFs due to multiple report types (e.g. Active Reports and PDFs) being passed in. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1544 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|  &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Specification Group names can now be up to 50 characters (previously set to 25) &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1543 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|  &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where lab-specific technicians could appear in dropdown selections when the Sampled By list (ID 20006) was set to &amp;quot;Global Only&amp;quot; has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1514 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| USPSI &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The header &amp;quot;Compressive Strength of Concrete Cylinders Cast in Place in Cylindrical Molds&amp;quot; of CIP100 specimens in Concrete Test Reports is now corrected to refer &amp;quot;Cylindrical&amp;quot; instead of &amp;quot;Cylinderical&amp;quot;. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1479 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|  &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| For the following moisture content test screens, the field Nominal Aggregate Size (mm) has been replaced with the dropdown selection Maximum Particle Size to indicate the maximum sieve size with 100% material passing in accordance with standard ASTM D 2216.&lt;br /&gt;
* Water Content of Soil and Rock [ASTM D 2216] (ID 110060)&lt;br /&gt;
* Moisture Content of Soil and Rock [ASTM D 2216 - 2010] (ID 110066)&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1439 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| USHVJ &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Fixed an issue where publishing an email to contacts with commas in their name could raise a &amp;quot;Subscript out of range&amp;quot; error. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1368 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| USTWI &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| When publishing a document the distribution list is still populated when a deleted user is a member of the project. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1367 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| USTWI &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| This change attempts to resolve an occasionally error that occurred during publishing, &amp;quot;Error while publishing binary: Error -2147024882: Not enough storage is available to complete this operation&amp;quot;.  It also adds further detail to error messages in this area to help identify the location where the error occurs. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1366 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|  &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| A bug where user document column names containing hyphens could not be deleted has been fixed.  These are now correctly enclosed in square brackets, and escaped if necessary. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1365 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| USWSB &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The moisture content rounding of &amp;quot;oven-dried&amp;quot; moisture content is to nearest 0.1% for Moisture, Ash and Organic Content [ASTM D 2974 - 2007]. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1364 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| AUDEW&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| An issue where Density Offset Report (ID 17036) could not be loaded has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1363 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| NZGEO&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The test method no longer reports twice on the nuclear density report. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1362 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| USPSI&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The following can no longer appear in the Accredited Documents trees in the QEST Administrator Console, as they are not applicable:&lt;br /&gt;
* (ID 18010) Billing&lt;br /&gt;
* (ID 18015) Billing Summary&lt;br /&gt;
* (ID 18019) Invoice&lt;br /&gt;
* (ID 18020) Timekeeping&lt;br /&gt;
* (ID 18021) Timekeeping Records&lt;br /&gt;
* (ID 90022) Archived Test Report&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1361 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|  &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| The bug where the Hanson &amp;quot;Concrete Test Delete Export&amp;quot; integrator was not being invoked correctly from QESTField/QESTNET has been fixed. &lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| QPM_1360 &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| NZGEO &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;| Reports with NZGEO Custom Header now load without errors when the preliminary field value is null.&lt;br /&gt;
&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
	<entry>
		<id>http://online.spectraqest.com/index.php?title=QEST_Platform_4.5.2939&amp;diff=31368</id>
		<title>QEST Platform 4.5.2939</title>
		<link rel="alternate" type="text/html" href="http://online.spectraqest.com/index.php?title=QEST_Platform_4.5.2939&amp;diff=31368"/>
		<updated>2018-01-18T01:15:49Z</updated>

		<summary type="html">&lt;p&gt;John.meegan: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==QEST Platform 4.5.2939==&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
!Bug/CR ID&lt;br /&gt;
!Customer Code&lt;br /&gt;
!Customer Reference&lt;br /&gt;
!Product(s) Modified&lt;br /&gt;
!Name&lt;br /&gt;
!Release Notes&lt;br /&gt;
&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white smoke;&amp;quot;|Bug#5760&lt;br /&gt;
|style=&amp;quot;background:white smoke;&amp;quot;|AUCOF&lt;br /&gt;
|style=&amp;quot;background:white smoke;&amp;quot;|Cof16.125&lt;br /&gt;
|style=&amp;quot;background:white smoke;&amp;quot;|QESTLab&lt;br /&gt;
|style=&amp;quot;background:white smoke;&amp;quot;|Hydrometer: Calculation corrections for AS/RMS tests&lt;br /&gt;
|style=&amp;quot;background:white smoke;&amp;quot;|The following changes have been made to test screens Grading - Hydrometer [AS 1289.3.6.3] (ID 11021) and Grading - Hydrometer [RMS T190] (ID 11022)&lt;br /&gt;
* The Total Dry Mass of the hydrometer sub-sample will now be calculated according to formula 7(2) of the standard AS 1289.3.6.3&lt;br /&gt;
* New fields have been added to the Pretreatment tab to determine Mass of Dispersing Agent (g)&lt;br /&gt;
* A bug which caused the field Mass Before Pretreatment (g) to become unlocked has been fixed.&lt;br /&gt;
* The value of Mass After Pretreatment (g) will be adjusted using the Mass of Dispersing Agent (g) rather than the value of Dispersant Correction Ca.&lt;br /&gt;
* Mass After Pretreatment (g) will no longer overwrite the dry mass of the sub-sample after a split at the 2.36mm sieve&lt;br /&gt;
* The hydrometer reading/depth calibration will now be interpolated using a line of best fit of all calibrated points, rather than the two neighbouring point, when determining the value of correction factor F1&lt;br /&gt;
* Correction factor F2 will now be calculated rather than derived from a lookup table. This removes the restriction placed on the value of soil density.&lt;br /&gt;
* The calculation for Adj. Smaller than D (%) will now apply the soil density correction factor.&lt;br /&gt;
Additionally, a bug which caused the warning text to display incorrectly for some hydrometer tests has been fixed.&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|Bug#6689&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|AUGCC &lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|QESTLab&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|CBR values are not updated correctly&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|An issue where changing Seating Deflection or Seating Load would not update CBR values correctly has been fixed.&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|Bug#6827&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|AUPAR&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|QESTLab&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|CBR: Load Cell Reading Convertion&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|For Q113 CBR test screens, users can now directly record the force readings from a load cell and QESTLab will converts the values into Newton based on the force unit set for the selected load cell equipment.&lt;br /&gt;
&amp;lt;BR&amp;gt;&lt;br /&gt;
The following changes have been made as well:&lt;br /&gt;
- Drop-down boxes and edit boxes are now aligned in Force Indicator frame.&lt;br /&gt;
- A warning message will show up when users switching between different force indicators (proving ring and load cell) and any penetration results are entered.&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white smoke;&amp;quot;|Bug#6891&lt;br /&gt;
|style=&amp;quot;background:white smoke;&amp;quot;|AUQMR&lt;br /&gt;
|style=&amp;quot;background:white smoke;&amp;quot;|&lt;br /&gt;
|style=&amp;quot;background:white smoke;&amp;quot;|QESTLab&lt;br /&gt;
|style=&amp;quot;background:white smoke;&amp;quot;|CBR: Negative correction&lt;br /&gt;
|style=&amp;quot;background:white smoke;&amp;quot;|Negative correction is no longer applied for CBR values on CBR test screens.&lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|Bug#6994&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|INTERNAL&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|QESTLab&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|California Bearing Ratio - Import MDD result&lt;br /&gt;
|style=&amp;quot;background:white;&amp;quot;|Pressing the Import button in the compaction section of the CBR screen now imports the MDD and OMC values from the specified sample instead of throwing a runtime error 91.&lt;br /&gt;
&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>John.meegan</name></author>
	</entry>
</feed>