4.0 Release Notes: Difference between revisions
Benny.thomas (talk | contribs) No edit summary |
Lief.martin (talk | contribs) mNo edit summary |
||
| (One intermediate revision by one other user not shown) | |||
| Line 25: | Line 25: | ||
{{QESTLab:QESTLab 4.0.1300 RC}} | {{QESTLab:QESTLab 4.0.1300 RC}} | ||
---- | ---- | ||
{{QEST Platform 4.0.3006 Release Notes|QEST Platform 4.0.3006 Release Notes}} | |||
Latest revision as of 04:25, 26 March 2018
QESTLab 4.0.100 TP
| Bug/CR ID | Customer Code | Customer Reference | Name | Release Notes |
|---|---|---|---|---|
| Bug#2936 | GLFUG | n/a | Single Dry Mass Reading for Moisture Contents | A lab-level option called "Enable Single Dry Mass for MC" has been added to the QEST Administrator Console, in Regions & Laboratories -> tab Options -> section Kiosk -> Enable Single Dry Mass for MC. When set to True, only one dry mass reading is required for Moisture Contents calculations. |
| Bug#3032 | GLFUG | n/a | Equipment | When adding new Equipments, Qest Lab will check for globally uniqueness of Equipment code, across all Equipment types and Laboratories, if the option "Globally Unique Equipment Code" in QEST Administrator Console is set to True. |
| Bug#3079 | GLFUG | n/a | Project list | Filename in the Project list now refreshes, immediately after uploading or removing a file. In addition the caption is now "File Name". |
| Bug#3094 | GLFUG | Soil description [110259] | TAB order in the Soil description [110259] test is fixed now. After adding layers, the cursor now moves into “height” of the first point. | |
| Bug#3212 | INTERNAL | Atterberg Limits | Following issues in some Atterberg screens are fixed now. - Dry mass 1,2,3 are disables and greyed randomly on screen. -10044 [AS 1289.3.1.2/2.1/3.1/4.1],10045 [TSA-MAT-TP141,143] extra test was clearing at refresh, deleting the result. - Unnecessary scroll bar and broken LS frame in some screens (E.g., Q104A, Q105,Q106) - "Use Constant Mass Drying.." check box was not working when Kiosk is not licenced ("BarcodeScanner" "feature" in the license file) and Lab level Option, "Enable Single Dry Mass for MC" not enabled - Plastic Limit, Final Dry mass was not formatting until refresh the screen. - Atterberg Limits [TSA-MAT-TP141,143] [10045] now reports Liquid Limit, Plastic Limit and Plasticity Index to the nearest whole number. | |
| Bug#3284 | GLFUG | n/a | UU Triaxial Compression Test | The "Strain Only" offset on UU Triaxial tests now excludes points between the offset and the left point used to position the tangent line. |
| Bug#3328 | GLFUG | Sub-sampling history graph | Two enhancements have been made on the sub-sampling history graph: - For large graphs that require scrollbar, the graph will now redraw when the scrollbar is being scrolled. - The test icons that are on the edge of the graph will no longer be cut off. | |
| Bug#3434 | GLFUG | N/A | QESTLab Notifications | The ordering of the 'Samples with Duplicate IDs' which appears in the QESTLab Notifications Popup, has been updated to ensure that the Samples with the duplicate IDs are next to each other. |
| Bug#3441 | INTERNAL | INTERNAL | Project Management | A bug which resulted in the 'Plate Reports' tab showing up in Project Management on non-Fugro databases has been fixed. |
| Bug#3452 | AUQLT | QU_EQUIP_ERROR | Equipment Deletion | A bug which resulted in an equipment not deleting when it had more than one task, has now been fixed. |
| Bug#3539 | INTERNAL | INTERNAL | Roles | Fixed a bug where an error message could be triggered when looking at the permissions for a Role. |
| Bug#3552 | INTERNAL | INTERNAL | User Login | A bug when creating a user login that resulting in QESTLab crashing, has been fixed. |
| CR#1605 | INTERNAL | CR1507 | Test Stages - Upcharge | Each Test Stage can now have associated Billable Items. There are two types of charges for Billable Items of Test Stages: base-charge and up-charge. This is controlled via an "UpCharge" flag on the Billable Item list. Fee Schedules need to be created for the base-charged and up-charged Billable Items separately. When billing for a test stage is generated, if up-charge is required, then two charge records will be raised, one for the base-charge Fee Schedule, and the other for the up-charge one. Otherwise, only one charge for the base-charged Fee Schedule will be raised. |
| CR#1606 | INTERNAL | CR1508 | Sub-sampling at an angle | Samples can now be sub-sampled at an angle. |
| CR#1646 | INTERNAL | INTERNAL | Permissions for Test Stages | Users can be given permissions for individual Test Stages through the People & Roles management module within QESTLab. |
| CR#1647 | INTERNAL | INTERNAL | Test Stages - Billing | Test Stages now can have associated Billable Items and Fee Schedules. When billing for a test stage is generated, the Fee Schedule linked to that test stage will be raised. |
| CR#1652 | INTERNAL | INTERNAL | Sample Logging screen | Sample Logging screen |
| CR#1694 | INTERNAL | INTERNAL | Custom equipment calibration documents for Excel | QESTLab now includes the ability for administrators to define their own equipment calibration documents, and provide data entry via an Excel worksheet. Some additional documentation is provided in QESTOnline: http://online.spectraqest.com/index.php?title=QESTLab:Enhanced_User_Documents#Equipment_Calibration http://online.spectraqest.com/index.php?title=QESTLab:Equipment_Documents#Custom_Worksheets The QESTLab Plugin for Excel now has the ability to make multi-lingual worksheets, where labels are translated according to the language of the current QESTLab user. http://online.spectraqest.com/index.php?title=QESTLab:External_Documents_Plugin_for_Word_and_Excel_2007#Translatable_Text |
| CR#1848 | GLFUG | FUGRO | Retests | The Sample Article screen has been updated to allow tests that are retests to be easily identified. Previously, when the 'Sub-Sampling' tab was selected, all the tests that are assigned to this sample article or its children are shown on the sample article grid as a list with the title 'Test'. This list has been changed with any tests that are retests being moved to the bottom and placed beneath the tilte 'Retests'. When a sample article is selected on the 'Sub-Sampling' grid the tests which appear, that can be moved to different sample articles, will now appear green if the test 'has a retest' and blue if the test 'is a retest'. If one of these tests is clicked and not dragged then a label will appear detailing the related test. If the test 'is a retest' then the label will specify that it is a retest and show the details of Sample Article to which the original test is assigned to. This makes it easier to choose a sample article for the new test if the original sample article can no longer be used i.e. it is disturbed and the test requires it to be undisturbed. If the test 'has a retest' then the lablel will specify the details of the Sample Article to which the retest is assigned to. When a test that 'is a retest' is moved to a different Sample Article, the details that appear when clicking the original test will not update until the sample article has been refreshed. |
| CR#2013 | GLFUG | n/a | Soil Description for Identification of Soils (Visual-Manual Procedure) | A new field called 'Major Component' has been added to Sample Article (40000). Soil Description for Identification of Soils (Visual-Manual Procedure) (110259) has been changed so that it updates the Sample Article 'Major Component' when its 'Major Component' is changed. |
| CR#2038 | GLFUG | n/a | FILMS: Tests and Suitability | Tests that are set as unsuitable will now appear red on the Sample Article screen. |
| CR#2076 | GLFUG | SubSampling screen: testing complete threshold | In QEST Administrator Console, a new option called "Testing Complete Threshold (%)" has been added in the Options -> General -> Work Progress section. This option allows users to set work progress threshold (%), which will be used to decide whether a test is "complete" during sub-sampling. If the work progress (%) of a test is below this threshold, the test is deemed incomplete, and cannot be assigned to any subsampled/merged sample articles. If no value of "Testing Complete Threshold (%)" is set, a default value of 80% is used. | |
| CR#2079 | GLFUG | Manage Projects Interface- Handling 'inactive' projects | In the Manage Projects Interface, 'inactive' projects wouldn't normally be listed in the dropdown, unless the "show inactive" checkbox is selected. | |
| CR#2124 | GLFUG | N/A | Barcode Template | Smaller barcode template. |
| CR#2161 | GLFUG | n/a | Project Price List | Price List's have been changed to be selected per Project through the Manage Project tools. This means a single Price List can be shared by a number of Projects rather than a single Project having multiple Price Lists. |
QESTLab 4.0.200 RC
| Bug/CR ID | Customer Code | Customer Reference | Name | Release Notes |
|---|---|---|---|---|
| Bug#3577 | GLFUG | INTERNAL | Sub Sampling | The Sub Sampling Grid has been changed so that a sub-sample can be sampled accurate to 0.01 inches. This means that when the sample is sub-sampled it occurs at the offset seen on the 'Offset Preview'. |
| Bug#3591 | GLFUG | n/a | Pyknometer method added in Particle Density test names | Following test's names have been changed to differenciate between the large/small Pyknometer versions: Particle Density - Small PYK [BS 1377-2: 1990 cl 8.3][110909] Particle Density - Large PYK [BS 1377-2: 1990 cl 8.4][110913] |
| Bug#3592 | GLFUG | n/a | "Name=" has been removed from Liquid Limit test captions. | "Name=" has been removed from following test captions. Liquid Limit - Casagrande [BS 1377-2: 1990 cl 4.5][110943] Liquid Limit - Cone Penetrometer [BS 1377-2: 1990 cl 4.3][110944] Liquid Limit - One Point Cone Penetrometer [BS 1377-2: 1990 cl 4.4][110945] |
| Bug#3593 | GLFUG | n/a | Shipment Receipt Pictures | A bug that prevented pictures from being added to a shipment receipt has now been fixed. Any pictures added to a Shipment Receipt are now stored in the file system storage. The file storage location in the QEST Administrator Console. Select Options/System/Storage and enter a directory location into the 'File System Storage Location' option. |
| Bug#3594 | GLFUG | INTERNAL | Sample transfer Error 13 in specific labs | Fixed the error message which was getting when creating new sample requests in certain labs where the Formatting options were not set in QEST Administrator Console. |
| Bug#3632 | GLFUG | INTERNAL | Vertical Sub Sampling | An error which caused QESTLab to crash during Vertical Sub Sampling, has been fixed. |
| Bug#3645 | GLFUG | Create Specification Record | A bug which prevented a Specification Record from being created, has been fixed. | |
| Bug#3662 | INTERNAL | Plate Reports | 1 Increased the upper range of Void Ratio to include up to 8 on Oedometer report charts. 2 Fixed an error displaying Lab Technician on the Oedometer report. 3 Fixed the formats of Diameter, Height, Saturation, Differential Height and Moisture Content of the Oedometer report. 4 Fixed a wording issue on the Plate Report “correction required” window. Fugro: 20141017 - 119.3 ASTM OED report: void ration vs log(p) does not connect points correctly, uses a straight line and chooses an incorrect scale (void ratios can get to 8) Fugro: 20141017 - 119.6 Testing technician name on ASTM OED Report is incorrect Fugro: 20141017 - 119.8 ASTM OED report: Cv and Mv do not show and differential height should be to 2 d.p. Fugro: 20141017 - 119.10 OED reports: need to be able to include Becker interpretation | |
| Bug#3668 | GLFUG | Torvane and pocket Penetrometer Plate Report | A bug has been fixed on both Torvane (18950) and Pocket Penetrometer (18960) Plate Reports that caused the "Adaptor Size", "Undrained Shear Strength Estimate" and table notes to not be reported. Fugro: 20141020 - 130.4 TV test - results not shown on report | |
| Bug#3681 | GLFUG | Oedometer Plate Report | The following fixes have been made to the Oedomater plate report (18545). 1. The X-axis range on logarithmic charts now supports a wider range. 2. Charts in general have a fix to prevent 'precision-loss' that causes the maximum and/or minimum axis values to not be labelled. 3. Diameter and Height is now reported to the nearest 0.0005 inch. 4. Void Ratio is now reported to the 0.01 decimal. 5. Saturation is now reported to the 0.1 decimal. 6. Differential Height is now reported to the nearest 0.0005 inch. 7. Pressure is now reported to the nearest 0.01 ksf. Fugro: 20141021 - 155.1 ASTM D2435 (Oed) Report: x-axis should start at 0.1ksf, missing 5 initial stages Fugro: 20141021 - 155.2 ASTM D2435 (Oed) Report: Vertical axis; label start and end points Fugro: 20141021 - 155.3 ASTM D2435 (Oed) Report: Diameter and height to the nearest 0.0005 inch Fugro: 20141021 - 155.4 ASTM D2435 (Oed) Report: Technician name not shown in report Fugro: 20141021 - 155.5 ASTM D2435 (Oed) Report: Void Ratio in 0.01 decimal Fugro: 20141021 - 155.6 ASTM D2435 (Oed) Report: Saturation in 0.1 decimal Fugro: 20141021 - 155.7 ASTM D2435 (Oed) Report: Differential height to the nearest 0.0005 inch (page 3) Fugro: 20141021 - 155.8 ASTM D2435 (Oed) Report: Pressure to the nearest 0.01 ksf Fugro: 20141021 - 155.9 ASTM D2435 (Oed) Report: Cv and Mv are not populated in report (2 significant fig.) Fugro: 20141021 - 156 ASTM D2435 (Oed): Error reporting OED results on Sample1WAXC on project US1410 Foundation Investigation |
QESTLab 4.0.300 RC
| Bug/CR ID | Customer Code | Customer Reference | Name | Release Notes |
|---|---|---|---|---|
| Bug#3522 | GLFUG | [20141014].2 | Project Reference Documents | An issue has been fixed which was causing Reference Documents to not be uploadable to Projects. |
| Bug#3595 | GLFUG | INTERNAL | Sample Transfer Bin - Sync To Hive | When a sample is set to 'disposed' or set to 'not disposed' on the Sample Transfer Bin screen, the changes are synced to Construction Hive. Fugro: 20141015 - 81 Disposing of samples in kiosk through "move" functionality, no synch to CH occurs |
| Bug#3596 | INTERNAL | INTERNAL | Kiosk Login | A bug which prevented a Kiosk Login from being linked to a different barcode has now been fixed. Fugro: 20141015 - 88 Cannot change kiosk logins |
| Bug#3597 | GLFUG | n/a | Quarantined samples | 1. Quarantined samples cannot be moved to a location that is not marked as quarantined when moving bins. 2. Quarnatined samples will also get barcodes when printing. 3. On shipment receipt user can unclick quarantine directly. Fugro: 20141015 - 90.1 Quarantined samples can be moved to non-quarantine locations Fugro: 20141015 - 90.2 Quarantined samples should get barcodes Fugro: 20141015 - 25 Cannot unquarantine sample without workaround |
| Bug#3680 | GLFUG | Sample Transfer Request | The sample transfer request screen has been updated so that it now early searches for 100 samples at a time. A 'Next' and 'Prev' button have been added to the screen which show the next/previous 100 samples, that match the search criteria, when pressed. Fugro: 20141021 - 149 Sample Transfer Request, first load 100 samples instead of all | |
| Bug#3697 | GLFUG | n/a | Test stages disappear in Billable items | Selected test stages won't disappear after being selected and moving off the screen in the billable items list in the Singapore laboratory. Fugro: 20141014 - 65 Test stages do not stick in billable items |
| Bug#3699 | GLFUG | Triaxial Plate Reports | 1. Fixed an issue to ensure parity between the ordering of specimen in tables and charts. 2. The symbols for the effective intrepretation results now include an apostrophe. 3. Fixed an issue where the units wern't shown for the friction angle. 4. The B Value is now reported to two decimal places. 5. Fixed an issue where the consolidation chart was plotting inccorrect volume data. 6. Fixed an issue where images were not being printed. 7. Fixed an issue where S-T and P-Q charts were not showing the legend and points at discrete values strain. 8.The title for the effective results is changed from "Shearing" to “At peak effective stress ratio”. Fugro: 20141020 - 131.8 Multi stage, single specimen TRX reports legend on plots indicates incorrect stage, table orders stages incorrectly Fugro: 20141020 - 131.9 Multi stage, single specimen TRX reports should only show one Visual description, PD etc. (first page) Fugro: 20141022 - 177.1 BS CID Multistage Multi specimen Report: Missing Void Ratio, Degree of Saturation, Specific Gravity (shall be renamed to Particle Density in all BS tests and show in Mg/m3. Fugro: 20141022 - 177.2 BS CID Multistage Multi specimen Report: Differential pressure "N/A" instead of "10" Fugro: 20141022 - 177.3 BS CID Multistage Multi specimen Report: B-value shall be in 2 decimals Fugro: 20141022 - 177.4 BS CID Multistage Multi specimen Report: Volume change axis incorrect. Strain shall start at zero and positive values down and negative values plotted upwards. Fugro: 20141022 - 177.5 BS CID Multistage Multi specimen Report: Y-axis title not readable due to unit issue Fugro: 20141022 - 177.6 BS CID Multistage Multi specimen Report: Page 7&8 empty areas (for p/q, s/t and Mohr circles) | |
| Bug#3700 | GLFUG | Plate Reports | 1] Particle Density a] Clause 8.3 or 8.4 are now correctly printed per test b] The report test number now uses the prefix "PD" instead of "OM" 2] C-Triaxial a] The membrane correction at peak deviator is now correctly reported b] Section title "Shearing” changed to “At Stress Ratio”. c] Side Drains are now correctly reported. d] Fixed an error that caused the Mohr chart to sometime prompt an error and not be drawn. 3] Atterberg | |
| Bug#3701 | GLFUG | Sample Transfer Request | 1. Test Type no longer shows concrete testing. 2. Test Type width increases so that all tests in the list fit in the box. 3. The following notifications that appear on the notification screen have been reordered as follows: 'Samples received but not on shipping list' is now ordered by most recent first then by borehole, sample and depth. 'Shipments with no project selected' is now ordered by most recent then by shipment id and received by. 'Sample Transfer Requested' is now ordered by most recent then by Transfer ID. 'Samples with Duplicated IDs' is now ordered by most recent then by project, borehole and sample id. 'Quarantined Shipments' is now ordered by most recent then by shipment receipt id. 'Invoice Approvals' is now ordered by most recent then invoice id, client code and project code. 'Invoice Corrections' is now ordered by most recent then invoice id and project code. 'Invoices Corrected' is now ordered by most recent then invoice id, client code and project code. 'Plate Report Approvals' is now ordered by most recent then report id, client code and project code. 'Plate Report Corrections' is now ordered by most recent then report id and project code. 'Plate Reports Corrected' is now ordered by most recent then report id, client code and project code. Fugro: 20141023 - 205.1 Sample Transfer Request: Test type consists of concrete testing Fugro: 20141023 - 205.2 Sample Transfer Request: Test type can not be view fully due to limitation of space Fugro: 20141023 - 205.3 Sample Transfer Request: Sort list of QestLab notifications with latest on top (observed when logging in as Store Manager) | |
| Bug#3743 | GLFUG | Triaxial Plate Reports | 1. Time at 50% consolidation is now correctly reported 2. Fixed an issue where Failure mode was not correctly reported. Fugro: 20141027 - 234 QESTLab issue: Incorrect data being transferred from QestNet and QestLab for highlighted values for Specimen 1 (B-21, Sample 5-1). | |
| Bug#3772 | GLFUG | Plate Reports. | General 1. Several improvements have been made to the test method search criteria of plate reports to maintain integrity. UU Triaxial 2. An error has been fixed that caused the chart x-axis to be incorrectly scaled. External Report 3. Fixed an error that cause an popup message and the external report not to be openable. Fugro: 20141027 - 239 Chart Range is not correct on plate for what QestNet presents Fugro: 20141027 - 248.1 Problem: When creating PSD reports. If I select the blank line all test variations appear in the list to be reported. If I select an individual type. No items are displayed. Fugro: 20141027 - 248.2 Reports do don’t display curves, axis or % of fractions (see attached PDF) Fugro: 20141027 - 249 Cannot load an external test report via the plate reports module | |
| Bug#3773 | GLFUG | Task Type | A bug which resulted in an error message appearing when changing task type on the equipment screen, has been fixed. Fugro: 20141027 - 229 New calibration on pyknometer results in error 94 - can continue | |
| Bug#3807 | GLFUG | Test Stages | Test Stages has been updated so that it loads data straight from the database instead of through data.fields. | |
| Bug#3811 | GLFUG | Plate Reports | 1. The Fallcone plate report (18561) has been added to QESTLab. 2. The results for ASTM and BS Lab Vane tests have been readjusted with respect to changes made to the tests in QESTNet. 3. A bug has beeen fixed on Atterberg plate reports where data was being printed twice. 4. The UU Triaxial report now prints several results are centre aligned instead of decimal alignment. 5. An error has been fixed where the failure mode on the UU triaxial report was not being reported. 6. Serveral bug fixes have been made such that images are now correctly reported. 7. A bug has been fixed on the Oedometer chart such that its points are now correctly ordered. Fugro: 20141017 - 119.3 ASTM OED report: void ration vs log(p) does not connect points correctly, uses a straight line and chooses an incorrect scale (void ratios can get to 8) | |
| CR#2256 | GLFUG | n/a | Test Stages Competency | The competency grid on the User screen has been updated so that test stages appear and can be assigned a competency. |
| CR#2257 | GLFUG | n/a | Edit Login ID | A new button called 'Edit Login Name' now exists on the people screen which allows the user to change the Login Name. |
QESTLab 4.0.400 RC
| Bug/CR ID | Customer Code | Customer Reference | Name | Release Notes |
|---|---|---|---|---|
| Bug#3834 | GLFUG | 197 | Sample Article Mass | Sample Article Mass is now stored in the database in kilograms (kg) instead of grams (g) for SI Units. |
| Bug#3835 | GLFUG | [20141111] - 286 | Shipment Receipt Picture | A bug that resutled in an error message when uploading an image on the Shipment Receipt screen, has now been fixed. |
| Bug#3840 | GLFUG | [20141112] - 300, 301 | Plate Reports | Unit Weight, Bulk Density, Specific Gravity & Particle Density plate reports have now been reconfigured to correctly load test data. |
| Bug#3850 | GLFUG | [20141112] - KK Testing | Billing - Update Charges | Selecting a Project on the Update Charges tool now selects the corresponding Client. |
| Bug#3852 | GLFUG | [20141112] - KK Testing | External Test Report (18540) | The external test report, created through the plate reports tab, now allows the user to 'request for approval' and specify 'correction required' before signing the report. To allow the 'request for approval' of a plate report the QLA 'Allow users to request approval for a plate report' must be set to true. It can be found in QLA/Options/Test Reports |
| Bug#3873 | GLFUG | [20141113] - 308 | Shipment Receipt | Ordering of the sample articles in the sample receipt on the shipment receipt screen, is now done in alphanumeric order when ordered by 'Sample ID'. |
| Bug#3888 | GLFUG | INTERNAL | Sample Subsampling | A bug has been fixed on the Sample Subsampling screen, where 'merged' status of samples, when combining samples into one, was not being correctly updated. |
| CR#2253 | GLFUG | n/a | Shipment receipt deletion rules | Shipment receipts can now be deleted only when no samples have been associated with the receipt or no project has been associated with it. The same rule applies in Kiosk mode, specially when a receipt is added in Kiosk mode accidentally. In Kiosk mode the "Edit" menu botton is added, where the 'Delete' option is only enabled for Shipment receipts, when the above criteria is met. |
| CR#2254 | GLFUG | n/a | Sample Disposal button in red | Sample Disposal button's arrow is now red. |
| CR#2267 | GLFUG | Client on SampleTransfer Bins screen | 'Client Name' is now displayed instead of 'Client Code', on the SampleTransfer Bins screen, in the 'Client' column of 'Search' and 'Bin Details' grids. | |
| CR#2269 | GLFUG | Oedometer Plate Report | Stages that are set to be excluded from the report, are now excluded from the report. | |
| CR#2276 | GLFUG | System File Location | File System Location has been moved from QESTLab Administrator Console to the config.ini found in the QESTLab folder. To set the location add the following text to the file 'StorageLocation=<your storage location>' replacing <your storage location> with the storage location you wish to set. Make sure you press the return button after the location path to ensure there is a new line after the path. Example: [QESTLab Data] ConnectionString=QESTLab_FUGRO2 TemplateLocation=C:\Development Offline\Product Development\QEST Lab\Database Template StorageLocation=C:\QestLab Images |
QESTLab 4.0.500 RC
| Bug/CR ID | Customer Code | Customer Reference | Name | Release Notes |
|---|---|---|---|---|
| Bug#3960 | GLFUG | UAT4-25 | Moisture Tins used in QestNet, unlinking in QESTLab | Moisture Tins which are utilized in QESTNet for a test can now be unlinked in QESTLab under Equipment list. |
| Bug#3977 | GLFUG | UAT4-34 | Test Category for UU, UCS and MMD tests | The LTP test categories for the following tests have been updated. Changed from Advanced to Standard: - Triaxial UU - Unconsolidated Undrained Compression [ASTM D 2850] - Triaxial UU - Unconsolidated Undrained Compression [BS 1377 Part 7, cl.8] - Unconfined Compressive Strength [ASTM D 2166] - Unconfined Compressive Strength [BS 1377-7: 1990] Changed from Other to Standard: - Minimum Index Density [ASTM D 4253] - Maximum Index Density [ASTM D 4254] - Minimum Index Density [BS 1377-4: 1990 cl 4.4] - Dry Density/Moisture Content Relationship [BS 1377-4: 1990 cl 3.7] - Minimum Index Density [L-T-029] - Dry Density/Moisture Content Relationship [L-T-028] |
QESTLab 4.0.600 RC
| Bug/CR ID | Customer Code | Customer Reference | Name | Release Notes |
|---|---|---|---|---|
| Bug#3868 | GLFUG | INTERNAL | Shipment Receipt | 1. Samples that are Disposed, Combined, Merged and/or Subsampled will now be shown and locked in the sample receipt grid. 2. A bug has been fixed where the shipment receipt was clearing the Combined, Subsampled, Merged and/or Disposed status of a sample. 3. Marking a shipment receipt 'complete' now correctly locks samples. 4. A bug has been fixed where quarantining the shipment could change multiple statuses of samples instead of just the 'received' status. 5. Quarantining of a shipment will no long set 'unreceived' on samples that are Combined, Subsampled, Merged and/or Disposed. These sample types would cause a desync with Hive when the shipment is quarantined. |
| Bug#3904 | GLFUG | INTERNAL | Merge Sample Article Error | An error that occured after Merging two Sample Articles has now been fixed. |
| Bug#3906 | GLFUG | INTERNAL | Plate Reports: Error message on reports containing Bulk Density tests | A bug has been fixed which caused an "Invalid procedure call or argument" error message to appear relating to the field "Dry Density" when accessing a Plate Report containing the following tests:
|
| Bug#3907 | GLFUG | INTERNAL | Plate Reports: Incorrect orientation for Bulk density test results | An error has been fixed for Bulk Density and Unit Weight Plate Reports which caused test results to be incorrectly reported in columns rather than rows for the following tests:
Additionally, a bug which caused an "Error 438" message to appear when accessing a Unit Weight Plate Report containing test Bulk Density [BS 1377-2: 1990 cl 7.4] (110939) was also fixed. |
| Bug#3908 | GLFUG | INTERNAL | Plate Reports: Oedometer | An issue has been fixed where the Oedometer Plate Report would produce a pop up error message if the Oedometer test being reported had no data. |
| Bug#3920 | GLFUG | INTERNAL | UU Triaxial Plate Reports: Various issues | The following issues have been fixed for the UU Triaxial Plate Report (18530):
Please note that the Triaxial UU Undisturbed [ASTM D 2850] test (ID 110816) has been deprecated, and is superseded by Triaxial Stage (ID 111024). |
| Bug#3922 | GLFUG | INTERNAL | Soil Description[110259] | Empty Soil Description[110259] screens can now be left without any errors. |
| Bug#4019 | GLFUG | Plate Reports - Moisture Content | A bug has been fixed that caused 'disturbed' moisture content tests to not be reportable on the Water Content Plate Reports. | |
| Bug#4261 | GLFUG | MFD-B034 | Laboratory Vane [ASTM D 4648 (Method A)][110902] Reporting issues | Following reporting issues in the Laboratory Vane [ASTM D 4648 (Method A)][110902] has been fixed: - 'Size of Vane - Diameter & Height', 'Undrained Shear Strength Estimate', 'Residual Undrained Shear Strength Estimate' prompts are now displayed in two lines as per the approved Report Mockup 'ASTM_D4648 Vane.pdf' - 'Shear strength' of laboratory vane tests and residual tests marked as outside of equipment range will be reported with the 'greater than' (>) sign. - 'Test Date', 'Technician', 'Spring constant', 'Maximum Torque Reading', ' Rotation Rate', 'Rate of Shear' fields now report correctly. - 'Type of Vane Used' and 'Spring Number' font size is reduced to accommodate the equipment number completely. |
| Bug#4276 | GLFUG | MFD-B055 | Fallcone Plate Report: Rich Text displays incorrectly | A bug with the rich text format of prompt and notes for "Undisturbed Shear Strength" and "Remoulded Shear Strength" has been corrected. Also, an issue where the Fallcone Plate Report (18561) could not be built correctly for the Letter size has been addressed. |
| Bug#4393 | GLFUG | N/A | Atterberg Plate Report - BS test method results. | The Atterberg Limit plate report now correctly displays "Percent Passing 425 µm" for BS methods; fixed a typo where it displayed "Percent Passing 475 µm" and the results are now reported to a whole number. The Atterberg Plate Report Footer Note is now labelled "Summary of Plasticity Index Test Results" |
| Bug#4394 | GLFUG | N/A | Atterberg Limits Plate Report: Fixes to reporting of clauses 5.3 and 5.4 and presentation of result headings | The Atterberg Limits Plate Report now prints clauses 5.3 and 5.4, if any of the BS test methods are reported and a plastic limit is performed. An issue where the vertical alignment of "Symbol Number", "Borehole" and "Sample" headings on the Atterberg Limits Plate Report has been fixed. An issue where the "Passing 425 µm" heading was incorrectly presented on the Atterberg Limits Plate Report has been fixed. |
| Bug#4395 | GLFUG | N/A | Plate Reports: Sample Type reported incorrectly | A bug was causing Sample Type to be reported incorrectly on a number of Plate Reports. It will now report the value selected on the QESTNET test screen. |
| Bug#4396 | GLFUG | N/A | CIU Triaxial Plate Report: Specimen orientation incorrect | A bug has been fixed which caused the "Specimen Orientation" field for a sample on the CIU Triaxial Plate Report (ID 18532) to be reported incorrectly. |
| Bug#4398 | GLFUG | N/A | Triaxial Plate Reports: Incorrect order of points on Pore Water Pressure/Cell Pressure Graph | A bug, which resulted in the points on the Pore Water Pressure/Cell Pressure graph on Triaxial Plate Reports being out of order when no elapsed time had been set, has been fixed. |
| Bug#4399 | GLFUG | N/A | Triaxial Plate Reports: Chart fixes | The following fixes have been made on the CIU, CAU, CID and CAD Triaxial Plate Reports:
|
| Bug#4400 | GLFUG | N/A | Triaxial Plate Reports: Interpretation Results | Triaxial Plate Reports have been updated to only report Interpretation Results if selected to do so on the test. |
| Bug#4401 | GLFUG | N/A | Triaxial Plate Reports - Pictures not printed | A bug that caused pictures not to be printed on plate reports has been fixed. |
| Bug#4422 | GLFUG | MFD-B039 | Pycnometer [30101] :Calibration Masses data entry precision | "Pycnometer + Lid Mass (g)" and "Pycnometer + Liquid Mass (g)" in the calibration screen of Pycnometer [30101] now allows data entry with any precision, to accommodate 0.5 g in the BS 1377 - 2:1990 clause 8.4 and 0.001 g in the BS 1377 - 2:1990 clause 8.3 |
| Bug#4424 | GLFUG | MFD-B023 | Plate Report Footer: Long Project Codes Cause Wrapping | The issue which caused wrapping in the footer of the plate report when the project code is long has been addressed. |
| Bug#4435 | GLFUG | MFD-B046 | Equipment: Mould & Extension Height Calibration is Missing in Density Moulds | The missing Mould & Extension Height Calibration has been created in Density Moulds for BS min/max test. |
| Bug#4466 | GLFUG | MFD-B013, MFD-B056 | Soil Description and Visual Identification: Descriptions not saving correctly, various other issues | The following issues have been corrected for the test screens Soil Description (ID 110259) and Visual-Manual Identification of Soils [ASTM D 2488] (ID 110258):
|
| Bug#4483 | GLFUG | MFD-B031 | Unit Weight [ASTM D 7263] :Incorrect reporting of densities | Unit Weight [ASTM D 7263] now reports the correct values for Bulk Unit Weight and Dry Unit Weight, and in SI units, they are reported in Mg/m³. The "Intact"/"Undisturbed" option in the report now reflects the selection in the "Specimen Status" field. |
| Bug#4484 | GLFUG | MFD-B032, MFD-B033 | Torvane and Pocket Penetrometer Plate Reports: Incorrect precision for IP units | A bug was causing "Undrained Shear Strength Estimate" to be reported to the nearest whole number when IP units were used, instead of to one decimal place, for the following plate reports:
|
| Bug#4485 | GLFUG | MFD-B036,MFD-B037 | Min\Max Density Plate Report: Chart causing error message, view incorrect, format issues | The following issues have been fixed for the Min\Max Density Plate Report (ID18525):
|
| Bug#4486 | GLFUG | MFD-B038 | Organic Matter Plate Report: Incorrect Unit and Value for Test Temperature | The temperature unit has been changed to Celsius degree for IP unit. Also, the value now is converted from Kelvin to Celsius. The "By Portion Of" result heading has been changed to "By Proportion Of". |
| Bug#4538 | GLFUG | New database version format caused error during version comparison | An error caused by a change to the database version format has been corrected. An appropriate warning message is now shown. | |
| Bug#4630 | GLFUG | QESTLab Start-up: Directory Not Found message appears when directory exists | A bug has been fixed which caused a "Directory Not Found" error message to appear during QESTLab start-up when a directory did exist at the configured path. | |
| CR#2227 | INTERNAL | INTERNAL | Sample Transfer Request Enhancements | -"Due Date <=" caption has been changed to "Project Due Date <=" on the Sample Transfer Request screen. - Smaple are now listed in the Sample Transfer Request notification email. |
| CR#2277 | GLFUG | 251 | Equipment: Oedometer Load Frame | A new dedicated calibration document "Oedometer Load Frame" (31019) is available for the equipment item "Oedometer Load Frame" (30148). |
| CR#2784 | GLFUG | N/A | Sieve tests abbreviated as PSD | Sieve tests are now abbreviated 'SIV' instead of 'PSD'. |
QESTLab 4.0.700 RC
4.0.700 Release Notes - Bugs
4.0.700 Release Notes - CRs
| Bug/CR ID | Customer Code | Customer Reference | Name | Release Notes |
|---|---|---|---|---|
| Bug#4397 | GLFUG | N/A | Triaxial CIU - Consolidated Isotropically Undrained Compression [BS 1377: Part 8: 1990] - Report issues in the CIU Triaxial Plate Report | The following fixes have been made for the Triaxial CIU - Consolidated Isotropically Undrained Compression [BS 1377: Part 8: 1990] test on the CIU Triaxial Plate Report:
|
| Bug#4417 | GLFUG | MFD-B057, MFD-B058 | Multistage TRX tests - incorrect order of table headings | A bug has been fixed for all CIU/CAU/CID/CAD Single Triaxial Multi-Stage Tests, which caused the stage number in the table to not match the corresponding data in the grid.
|
| Bug#4503 | GLFUG | MFD-B061 | Oedometer Load Frame Calibration: Performance details not saved | A bug was preventing the "Date Performed" and the "Performed By" fields of the Oedometer Load Frame calibration screen (ID 31019) from being saved. This has been fixed. Additionally, a "Copy From Latest Calibration" button has been added to this screen. When clicked, this will copy the readings from the most recently performed calibration to reduce the amount of data entry repeated for each calibration. |
| Bug#4660 | GLFUG | INTERNAL | UU Triaxial Plate Report: Error when accessing reports for previous Triaxial test | A bug has been fixed which caused an error message to occur when accessing a UU Triaxial Plate Report (ID 18530) which referred to an instance of the following deprecated tests:
|
| Bug#4687 | GLFUG | N/A | Specifications: Error when copying an existing specification | A bug has been fixed which caused an error message to occur when a new specification was created by copying an existing specification. |
| Bug#4690 | GLFUG | N/A | Plate Reports: Data-less Charts appear incorrectly | Data-less charts on Plate Reports will now be displayed, from 0 to 1 range of the displayed units. A minimum data range for charts is now in effect. This will prevent charts with very small ranges from not displaying grid lines or excessive decimal places on the grid line numbering. |
| Bug#4691 | GLFUG | N/A | Plate Reports: Chart scaling fixes | The following fixes have been made on the CIU, CAU, CID and CAD Triaxial Plate Reports:
|
| Bug#4701 | GLFUG | QEST Administrator Console: Error when performing database upgrade | A bug which caused an error to occur when upgrading a database's structure via the QEST Administrator Console has been fixed. | |
| CR#2615 | GLFUG | n/a | Fugro Data Backbone: Samples and locations cannot be created for imported projects | Samples and Borehole Locations can no longer be added to projects imported from the Fugro Data Backbone on the Shipment Receipt screen (ID 41000). The Geotechnical Borehole Locations list (ID 20135) will also prevent adding locations to imported projects. |
| CR#2616 | GLFUG | n/a | Laboratories: Default Project Owner option added | A laboratory option has been added to allow users to choose a default value for the "Project Owner" field of newly created projects. This option can be found on the "Regions & Laboratories" screen of the QEST Administrator Console under the "Document Defaults" tab. |
| CR#2619 | GLFUG | n/a | Project Reporting Number | 1. Plate Reports will now use their Project's "Reporting Project No." field in-place for the "Project Code" for generation of the report's "Report No." which is printed in the page footer margin. If a value is not set for the "Reporting Project No.", the "Project Code" will be use in-place, as it was before this change. 2. The following functionality is enabled via the Document Level Option, the Project List (20002), "Copy Client Project No. to Reporting No.". When entering a "Client Project Number" for a Project, the value entered will also be copied to the Project's "Reporting Project No." as well. If the value entered is "N/A" or "Client Project Number" is cleared, "Project Code" will be copied to the "Reporting Project No.", if the value of "Reporting Project No." matched the previous value of "Client Project Number", in other words, clearing "Client Project Number" will not affect the "Reporting Project No." if it had been changed to a different value from the "Client Project Number". |
| CR#2620 | GLFUG | n/a | Sample Articles: Sub-sample ID format changes | The following changes have been made to the format of the IDs generated for sub-samples and merged samples:
|
| CR#2621 | GLFUG | n/a | UUID Generation change - Guid.comb() algorithm | QESTLab has been changed to generate UUID values that will be stored in the database using the Guid.Comb algorithm (), which will reduce database fragmentation and increase database access speed. |
QESTLab 4.0.800 RC
QESTNET.Upgrade 1.0.100 is required to upgrade the QESTLab Database.
4.0.800 Release Notes - Bugs
4.0.800 Release Notes - CRs
| Bug/CR ID | Customer Code | Customer Reference | Name | Release Notes |
|---|---|---|---|---|
| Bug#3924 | GLFUG | 20141015-96.3 | Plate Reports: Oedometer chart fixes | The following fixes have been made to the chart on the Oedometer Plate Report (ID 18545):
|
| Bug#4416 | GLFUG | NA | Oedometer Plate Report: Trimmed Initial Void Ratio Label | The issue where the initial void ratio label was cut off on the chart of Oedometer Plate Reports (ID 18545) has been addressed. |
| Bug#4770 | GLFUG | N/A | Plate Reports: Chart fixes | The following issues have been fixed for plate report charts:
|
| Bug#4815 | GLFUG | Multistage Triaxial: Leave Final Conditon Blank | The Final Condition field on plate reports for multi-stage triaxial tests now is reported as blank value. | |
| CR#2617 | GLFUG | n/a | Fugro Data Backbone: Project Record Control | The following restrictions have been added for projects imported from the data backbone within QESTLab:
|
| CR#2778 | GLFUG | n/a | Billable Items Description - Length increased to 256 characters | In all locations that a Billable Item is selected or seen, it will now allow the item name to have a length of up to 256 characters. |
QESTLab 4.0.900 RC
QESTNET.Upgrade 1.0.101 is required to upgrade the QESTLab Database.
| Bug/CR ID | Customer Code | Customer Reference | Name | Release Notes |
|---|---|---|---|---|
| Bug#4120 | GLFUG | N/A | Barcode Scanning: Added laboratory option to configure barcode header | The laboratory level option 'Virtual key code of the Barcode Header' has been added under the 'Kiosk' group. This option should be set to the virtual key code, in hexadecimal format, of the barcode header to be used. This needs to be consistent with the corresponding QESTNET setting. By default, the header &HC0& (the back-tick '`' key on the US keyboard) will be used.
|
| Bug#4423 | GLFUG | MFD-B035 | Plate Reports: Corrections and Approval | Following corrections have been made in the Plate Reports Corrections and Approval functionality: (Note that it is enabled by the "Allow users to request Approval for a Plate Report" Option in the QEST Administrator Console/Lab/Configuration/Options/Test Reports) - Users list to assign Approval of a Plate Report is restricted by the "Plate Report Signatory" permission. Note that the users list to assign for correction will populate all the users from the same Laboratory. |
| Bug#4742 | GLFUG | N/A | Triaxial Plate Reports: Report issues for BS 1377-8 tests | The following fixes have been made for the reporting of test Triaxial - Consolidated Isotropically Undrained Compression [BS 1377-8: 1990] on the CIU Triaxial Plate Report:
|
| Bug#4816 | GLFUG | n/a | Triaxial Plate Reports: Effective Stress Mohr's Circles not shown on multi-specimen reports | The Mohr's Circles plot on the CAD, CAU, CID and CIU Triaxial Plate Reports will now show both Effective Stress Mohr's Circles and Total Stress Mohr's Circles on multi-specimen reports. |
| Bug#4817 | GLFUG | n/a | CID Triaxial Plate Report: Various issues | The following fixes have been made for the CID Triaxial Plate Report (ID 18534):
|
| Bug#4869 | GLFUG | 20151017-CIU6,CIUm5,CIDm7 | Triaxial Plate Reports: Various Issues | The following issues have been addressed for the CAU, CAD, CIU and CID Triaxial Plate Reports:
|
| Bug#4940 | INTERNAL | Projects List: Entries not appearing initially, Invalid Use of Null errors | A bug which caused entries of the list Projects (ID 20002) to not appear correctly, and raised "Invalid Use of Null" errors when testing a read-only condition on a NULL column, has been fixed.
|
QESTLab 4.0.1000 RC
NOTE: QESTNET.Upgrade 1.0.206 is required to upgrade the QESTLab Database.
| Bug/CR ID | Customer Code | Customer Reference | Product(s) Modified | Name | Release Notes |
|---|---|---|---|---|---|
| Bug#4922 | GLFUG | n/a | QESTLab | Water Content Plate Report: Moisture Method | A bug has been fixed that caused the Moisture Method on the Water Content Plate Report to not be reported. |
| Bug#4923 | GLFUG | n/a | QESTLab | External Reports: DB error when uploading file | A bug has been fixed that occurred when attempting to upload an attachment to an External Test Report by displaying an error indicating that a database write was not successful. This has now been fixed and the write completes successfully. |
| Bug#4924 | GLFUG | n/a | QESTLab | Specific Gravity Plate Report: Caption Change | The Notes for 'Specific Gravity [ASTM D 854] [110908]' on a Specific Gravity Plate Report [18591] have had an error corrected. It will now state: " Average Specific Gravity includes material greater in size than 'X'", where 'X' is determined by the test. |
| Bug#4942 | GLFUG | n/a | QESTLab | Laboratory Vane [ASTM D 4648 (Method A)]: Estimated Shear Strength reported precision | A bug has been fixed for the Laboratory Vane [ASTM D 4648 (Method A)] (110902), Estimated Shear Strength is now reported to three significant figures. |
| Bug#4945 | GLFUG | n/a | QESTLab | UU Triaxial Plate Report: Rate of Strain | An issue where the rate of strain on the UU Triaxial Plate Report was reported in "per hours" instead of "per minutes" has been fixed. |
| Bug#4946 | GLFUG | n/a | QESTLab | UU Triaxial Plate Report: Cell Pressure | The Cell Pressure on the UU Triaxial Plate Report is now correctly reported, including SI units reported to the nearest 1 kPa. |
| Bug#4947 | GLFUG | n/a | QESTLab | UU Triaxial Plate Report: Membrane Thickness and Undrained Shear Strength | Membrane Thickness and Undrained Shear Strength are now correctly reported on the UU Triaxial Plate Report. |
| Bug#4951 | GLFUG | n/a | QESTLab | UU Triaxial Plate Report: Charts Not Draw Correctly | The following bugs have been fixed for the UU Triaxial Plate Report:
|
| Bug#4952 | GLFUG | n/a | QESTLab | UU Triaxial Plate Report: Incorrect Pagination | The following bugs on the UU Triaxial Plater Report has been addressed:
|
QESTLab 4.0.1100 RC, QESTField/QESTNET 4.0.18, Construction Hive 1.100.16136.0
QESTLab 4.0.1100 RC
| Bug/CR ID | Customer Code | Customer Reference | Product(s) Modified | Name | Release Notes |
|---|---|---|---|---|---|
| Bug#5081 | GLFUG | N/A | QESTLab | Lab Vane Plate Report | An issue where the BS lab vane test (110903) could not be reported on the Lab Vane Plate Report (18515) has been fixed. |
| CR#2575 | GLFUG | N/A | QESTLab | Particle Size Distribution Plate Report - Pipette Test | The Particle Size Distribution Plate Report (18510) now supports the Pipette Test, Particle Size Distribution - Wet Method & Sedimentation [BS 1377-2: 1990 cl 9.2, 9.4] (110950). |
| CR#2603 | GLFUG | CR008 | QESTLab | Fugro Report Style Changes | Plate Reports and Management Reports have been updated to support changes to the header and footers according to the Fugro Style guide.
|
| CR#2972 | GLFUG | QESTLab | Hive sync for laboratories | Laboratories and laboratory-specific reference data (such as test accreditations, default project owner etc) can now be exported to Construction Hive via the QEST Admin Console > Lab > Configuration > Regions & Laboratories. Saving a laboratory or manually clicking on the Hive icon at the top-right of the window will trigger the synchronization to Construction Hive.
|
QESTField/QESTNET 4.0.18
4.0.18 Release Notes - Bugs
4.0.18 Release Notes - CRs
| Bug/CR ID | Customer Code | Customer Reference | Product(s) Modified | Name | Release Notes |
|---|---|---|---|---|---|
| Bug#4444 | GLFUG | MFD-B040 | QESTField | Material preparation and finalisation stages: "PerformedBy" and "QESTCompleteDate" values not being set | The issue where "PerformedBy" and "QESTCompleteDate" values for material preparation and finalisation stages are not set consistently has been addressed. |
| Bug#4445 | GLFUG | MFD-B045 | QESTField | [L-T-028, L-T-029] Maximum Dry Density - 'Tare mass' before ' Wet Soil & Tare Mass' and the tin navigation to the correct tab | In the [L-T-028, L-T-029] Maximum Dry Density stage [MAWW/MADW], 'Tare mass' now comes before ' Wet Soil & Tare Mass' and scanning a tin navigates to the correct tab if the order of workflow is followed correctly. |
| Bug#4459 | GLFUG | MFD-B025 | QESTField | Laboratory Vane [ASTM D 4648 (Method A)] [110902] - Refreshing Calculations | Laboratory Vane [ASTM D 4648 (Method A)] test now refreshes calculations when readings are cleared in QESTNET. |
| Bug#4546 | GLFUG | N/A | QESTLab, QESTField | Pore Fluid Salinity in Test Calculations |
|
| Bug#4884 | GLFUG | QESTField | Moisture Tin Association | A moisture tin now disassociates the test when one dry mass readings is entered and the 'Calculate' button is clicked. The moisture tin will also re-associate with a test which still has any empty dry mass reading, by deleting the Tare ID and re-entering a Tare ID either manually or by barcode scan. | |
| Bug#4895 | GLFUG | 20151017-CIU3 | QESTField | Triaxial tests: Request for 6 diameter and height measurements | Triaxial tests now allows for up to 6 measurements for height and diameter. |
| Bug#4896 | GLFUG | 20151017-CIUm2 | QESTField | Triaxial: LTP Confining pressure not showing | The issue where LTP Confining pressure is not populated for multi stage single specimen Triaxial tests has been addressed. |
| Bug#4937 | GLFUG | N/A | QESTField | Laboratory Vane [ASTM D 4648] - Shear Stength rounding issue | The individual Shear Strength readings are now displayed to 1 decimal place and the Final Average Shear Strength is displayed to 3 significant figures. |
| Bug#5042 | GLFUG | QESTField | Prevent duplicate samples during incomplete sync from Construction Hive | When saving an LTP in Construction Hive, the import process to QESTNET can occasionally fail (for various reasons such as broken database connections etc). This could leave data partially imported, which would result in the creation of duplicate sample articles on a subsequent synchronization. The import process is now run in a single transaction, which means that a sync failure will leave the data in its original state. | |
| Bug#5103 | GLFUG | 20151210-1,2,3,4 | QESTField | Triaxial: Calculation and Chart Issues | The following changes have been made for Triaxial Consolidated Isotropically Undrained Compression tests:
|
| Bug#5142 | GLFUG | MFD-B039 | QESTField | Particle Density [BS 1377-2: 1990 cl 8.3 and cl 8.4] : Wallingford Method -Potential Calculation Issue | An issue, which can potentially cause calculations in Particle Density tests not being refreshed, has been addressed. |
| Bug#5146 | GLFUG | 20151218-10, 6b | QESTField | Pipette - Enter time to nearest second | Time fields in the Particle Size Distribution - Wet Method & Pipette [BS 1377-2: 1990 cl 9.2, 9.4] now contain the hh:mm:ss format, allowing to enter the seconds. |
| Bug#5196 | INTERNAL | QESTField | Triaxial: Finial checking stage is not locked | The issue where QCT finial checking stage is not locked for Triaxial tests has been fixed. | |
| Bug#5198 | GLFUG | MFD-B030 | QESTField | Scanning barcode overwrites existing tin IDs | Now, scanning a tin only populates empty tin fields to avoid unexpected data loss. |
| Bug#5203 | GLFUG | 20160108 | QESTField | FDBB Hydrometer test export | Hydrometer tests will now export to the fdbb. |
| Bug#5217 | INTERNAL | QESTField | Equipment association: Location checking | Now, scanning equipment barcode to associate a test checks the location of the equipment and the test. If they are not under same location, the message, "The equipment item is not under same location with this test.", will appear. | |
| Bug#5223 | GLFUG | 20160114-1 | QESTField | Pipette - Sedimentation only reduced test sieves included in the chart in the SED stage. | Particle Size Distribution - Wet Method & Pipette [BS 1377 Part 2: 1990 cl 9.2, 9.4] - Sedimentation only test now plots the Reduced test sieves in the chart in the SED stage. |
| Bug#5224 | GLFUG | 20160114-2 | QESTField | Pipette - Specimen Reading date/times calculated based on Start date/time | Particle Size Distribution - Wet Method & Pipette [BS 1377 Part 2: 1990 cl 9.2, 9.4] - Specimen Reading date/times are now calculated based on the Start date/time instead of the Shaking end date/time. |
| Bug#5225 | GLFUG | 20160114-3 | QESTField | Pipette Sedimentation only test - populate masses from the reduced sieve test | Particle Size Distribution - Wet Method & Pipette [BS 1377 Part 2: 1990 cl 9.2, 9.4] - Sedimentation only test now populates below masses from the preparatory reduced sieve test initially, which can be overwritten by the user.
|
| Bug#5281 | INTERNAL | QESTField | Particle Size Distribution: Sieve Size Unit | From now, the 'Size' field will be stored in SI unit, metres for particle size distribution sieve tests. The patch script 'Fugro.DBB.Patch_PSDSieve_Size.sql to update the existing sieve size values will need to be executed. | |
| Bug#5314 | GLFUG | FDBB | QESTField | Triaxial test: mohr circles mapping | The fdbb objects have been updated and mohr circle cohesion and friction angle in Triaxial tests will be included in fdbb exporting. |
| Bug#5322 | GLFUG | QESTField | Incorrect label on ASTM D 422: "Air Dry and Tare Mass (Dispersant Mass) (g)" | Incorrect label on ASTM D 422 "Air Dry and Tare Mass (Dispersant Mass) (g)" is corrected to "Air Dry and Tare Mass (g)" | |
| Bug#5349 | GLFUG | QESTField | Triaxial UU - Axial strain and area not calculating | The axial strain calculation was not using the correct height value for UU triaxials. This has been changed to use the initial triaxial specimen height. Once the axial strain calculates, the area then calculates correctly. | |
| Bug#5351 | GLFUG | N/A | QESTField | FDBB: Exporting Hydrometer test error | The HydrometerTest class is now created and sent instead of the abstract class SedimentationTest when exporting to the fdbb, |
| Bug#5370 | GLFUG | QESTField | Particle Size Distribution - Wet Method & Pipette [BS 1377-2: 1990 cl 9.2, 9.4]: K not calculating when the calculation method is 'Percentage of whole sample' and the test is started as 'Sedimentation only'. | Particles Smaller (K) values now calculate when the calculation method is 'Percentage of whole sample' and the test is started as 'Sedimentation only', in the Particle Size Distribution - Wet Method & Pipette [BS 1377-2: 1990 cl 9.2, 9.4] | |
| Bug#5371 | INTERNAL | QESTField | PSD: Sieve size checking issues due to double and float conversions between units | In Sieve tests, sieve size checking issues which resulted in incorrect calculations due to discounting available sieves has been fixed. | |
| Bug#5377 | INTERNAL | QESTField | Particle Size Distribution - Wet Method & Sedimentation [BS 1377-2: 1990 cl 9.2, 9.4]: Incorrect value of percentage passing 63µm | The percentage passing 63µm sieve from full sieve test will be used to calculate K values if a test starts as "Sedimentation Only" and then a full sieve test is added. | |
| Bug#5378 | INTERNAL | QESTField | Particle Size Distribution - Wet Method & Sedimentation [BS 1377-2: 1990 cl 9.2, 9.4]: Incorrect warning message about carrying out a combined test | The percentage retained on pan will no longer use to determine whether a combined test should be carried out after enter values on the reduced sieve test for a "Sedimentation Only" test. | |
| Bug#5380 | INTERNAL | QESTField | Particle Size Distribution - Wet Method & Sedimentation [BS 1377-2: 1990 cl 9.2, 9.4]: Exporting percentage passing for reduced sieves | Now, the percentage passing value of reduced sieves will be exported to Fugro Data Backbone for Particle Size Distribution - Wet Method & Sedimentation [BS 1377-2: 1990 cl 9.2, 9.4] if the test starts with sedimentation only and has no associated Particle Size Distribution test. | |
| Bug#5381 | GLFUG | 20160211-1 | QESTField | Disable all the buttons during calculation | For all the tests in QESTField, buttons are no longer enabled after the calculation button is clicked until calculations are complete. |
| Bug#5382 | GLFUG | QESTField | Particle Size Distribution: Sieve set diameter does not save on any stage | The issue where sieve set diameter and width did not save on any stage in Particle Size Distribution tests has been addressed. | |
| Bug#5383 | GLFUG | QESTField | Particle Size Distribution - Wet Method & Sedimentation [BS 1377-2: 1990 cl 9.2, 9.4] : Moisture Content result not showing on the QC stage | The moisture content result of Particle Size Distribution - Wet Method & Sedimentation [BS 1377-2: 1990 cl 9.2, 9.4] has been added to the QC stage. | |
| CR#2742 | GLFUG | MFD-F023 | QESTField | TRX UU/UCS: Unnecessary Equipment |
|
| CR#2748 | GLFUG | MFD-018 | QESTField | ASTM Organic Content: Redundant Wet & Tare Mass entry when Oven-Dried | The 'Wet Soil and Tare Mass' entry will be locked when 'Oven-Dried' is selected in the 'Moisture Content By Proportion Of' drop down. |
| CR#2749 | GLFUG | MFD-F019,MFD-F020 | QESTField | ASTM Min/Max Dry Density Test Improvements | The following changes have been implemented to improve ASTM Min/Max Dry Density tests:
|
| CR#2764 | GLFUG | N/A | QESTField | Laboratory Vane: Warning when vane rotation exceeds range | A warning message has been created for Laboratory Vane tests. The message will appear when the vane rotation goes beyond 180 degree and query the tester whether the reading means to exceed machine limitation. It will not disappear until the check box "Rotation Greater than 180° " is checked. |
| CR#2814 | GLFUG | QESTLab | Sampling device column removed from borehole location list | The sampling device column has been removed from borehole location list. | |
| CR#2815 | GLFUG | QESTField | Sampling device column removed from borehole location list | The sampling device export integrator is no longer used. This integrator section should be removed from the QESTNET.exe.config. Contact Spectra QEST Help Desk if you require assistance in updating your config file. | |
| CR#2923 | GLFUG | N/A | QESTField | Sample suitability | The suitability bullet points have been changed to one check box which will be selected only if the sample/test is unsuitable. |
| CR#3030 | GLFUG | 20151017-CIU1 | QESTField | Triaxial: Misleading LTP condition labels | The caption of LTP confining pressure has been modified to 'Horizontal Effective Stress (σ′h)' for both Isotropic and Anisotropic Triaxial tests. Also, for Anisotropic Triaxial tests, the caption of LTP Anisotropic Stress has been changed to 'Vertical Effective Stress (σ′v)'. |
| CR#3115 | GLFUG | Other | Domain Object Factory Unmapped Properties Configuration | The errors of the form "Property: derivationMethodSets not found in class Project but was encountered in package from databackbone" that exist to inform us that the databackbone sent an unknown property can now be configured not to be produced. Specific properties can also be ignored by configuration, this is unnecessary to use for properties that specify <UnmappedPropertyBehaviour value="Ignore"/>. |
Construction Hive 1.100.16136.0
| Bug/CR ID | Customer Code | Customer Reference | Product(s) Modified | Name | Release Notes |
|---|---|---|---|---|---|
| Bug#4829 | GLFUG | N/A | Construction Hive | LTP Suitability Tooltip - Suitability Remarks | The tooltip used for tests for which the sample has been marked as unsuitable in QESTNet now shows the user-entered reason for marking the sample as unsuitable for testing. |
| Bug#5153 | INTERNAL | Construction Hive | Searching by date with non-US locales | Searching by dates for users with an Australian or UK locale setting would silently fail because values in the browser were still displayed in mm/dd/yyyy format (e.g. 25/12/2015) but would be interpreted on the Hive server as though they were dd/mm/yyyy formats. This no longer occurs. | |
| CR#2247 | GLFUG | 66 | Construction Hive, QESTLab, QESTField | Remove Sampling Device from Location list | Borehole locations no longer have an associated sampling device. As a result, the default diameter for undisturbed samples no longer comes from the sampling device.
|
| CR#2607 | GLFUG | CR008 | Construction Hive | Milestone report styles v4.0 | The milestone reports generated by QESTLab have had their logos, margins and strap lines updated to reflect the Fugro style guide v4.0. |
| CR#2962 | GLFUG | 20151017-CIU1 | QESTField, Construction Hive | Triaxial Test Condition Terminology Updated | For Consolidated Triaxial Tests:
|
| CR#2989 | INTERNAL | Construction Hive | Force user to select notification setting on registration | New users registering for Construction Hive are now forced to select a document notification option. Previously this would default to "Notify me immediately when I receive a new document". | |
| CR#3035 | USPSI | QNET635 | Construction Hive | i2ms export - split_sample_id uses qestnet FieldSampleID | To support new workflows in QESTNet 4.1, and retain backwards compatibility, the header field "split_sample_id" will now fall-back on the "FieldSampleID" field, as a fallback from either "_SplitSampleID" (for asphalt samples) or "ClientSampleID" (for agg/soil samples). |
| CR#3080 | USPSI | PSI1436 | Construction Hive | i2ms exports - ignore [bracketed] headers | The I2MS export configuration for some header fields has been modified so that all text following an opening square bracket '[' will be omitted.
|
QESTLab 4.0.1200 RC, QESTField/QESTNET 4.0.19 (QESTNET.Upgrade 1.0.208)
| Bug/CR ID | Customer Code | Customer Reference | Product(s) Modified | Name | Release Notes |
|---|---|---|---|---|---|
| Bug#3971 | GLFUG | n/a | QESTField | Incremental Oedometer - Excluding from Report check-box not required for Stage 0. | On the Incremental Oedometer workflow, there no longer exists a check-box to exclude stage 0 from the report. All other stages will continue to have the check-box allowing them to be excluded from the report. |
| Bug#5426 | GLFUG | n/a | QESTLab | QEST Admin Console: Running Database Structure Update reverts test condition changes | A bug has been fixed which caused changes made to the configuration of test stages to be reverted when a Database Structure Update was run through the QEST Administrator Console.
|
| Bug#5447 | GLFUG | n/a | QESTField, QESTLab | Images stored in Storage Location - Changing sample ID causes an error when viewing images | When images are loaded, QESTNet will no longer throw an error if the Sample ID has changed since the image was uploaded. Also, QESTLab will now store the file path and file name in the database separately to be consistent with QESTNet. |
| Bug#5448 | GLFUG | MFD-B087 | QESTField | Triaxial Tests: Changing a single-specimen test to multi-specimen does not remove additional stages | Previously when a multi-stage single-specimen Triaxial test was changed to a multi-stage multi-specimen Triaxial test on a Laboratory Test Programme, the additional triaxial stages would not be removed from the first specimen. This has been fixed. |
| Bug#5449 | GLFUG | MFD-B088 | QESTLab | Unconfined Compressive Strength Plate Report: Missing values and presentation issues | The following issues have been fixed for the Unconfined Compressive Strength Plate Report (ID 18539) when reporting Unconfined Compressive Strength [ASTM D 2166] (ID 110912) tests:
|
| Bug#5451 | GLFUG | n/a | QESTLab | UU Plate report: chart and report formatting issue | The following issues for UU plate report BS standard has bee fixed:
|
| Bug#5459 | GLFUG | MFD-B089 | QESTLab | Triaxial Plate Report: triaxial saturation method not reporting | A bug which caused the method of saturation not being transferred over into plate reports from QESTNet for CID and CIU Triaxial tests has been fixed |
| Bug#5487 | GLFUG | n/a | QESTLab | Sub Sampling - Error Message | When sub-sampling, QESTLab will no longer throw an error when a newly created child sample article is clicked on in the sample article grid or chart. |
| Bug#5518 | GLFUG | n/a | QESTField | Cancelled Test Assignments | Cancelled Test Assignments will now update correctly. Problems relating to the UCT test mapping from an assignment have been fixed. |
| Bug#5541 | GLFUG | QESTLab | Oedometer Plate Report: coefficient of consolidation and coefficient of volume compressibility values are missing | A bug which caused Coefficient of Consolidation and Coefficient of Volume compressibility values to not be reported correctly on the Oedometer plate report has been fixed. | |
| Bug#5555 | GLFUG | QESTField | Fdbb Incremental Oedometer Max Preconsolidation | The maxPreconsolidation properties in fdbb IloInterpretation have been renamed with max removed from them. | |
| Bug#5574 | GLFUG | QESTField | Fdbb Lab Vane performedAtDate | The performedAtDate is set for Lab Vane tests based on the completion date of the Measurement stage of the test. | |
| Bug#5575 | GLFUG | QESTField | Fdbb - Triaxial particle density | Particle density is now sent instead of specific gravity for all triaxial tests. | |
| Bug#5576 | GLFUG | QESTField | Fdbb Triaxial TrxConsolidationPhaseInterpretation | A fddb object type uuid has been added for TrxConsolidationPhaseInterpretation. | |
| Bug#5581 | GLFUG | QESTField | Fdbb - Sample null values | Barcode and Diameter are no longer sent. Depth, Length and Mass will not send a value if they are null. | |
| Bug#5616 | GLFUG | QESTField | QESTNET: Cannot access Sample Articles with associated user document tests | A bug has been fixed which caused a "No mapping configuration found" error to appear when loading a Sample Article with an associated user document test in QESTNET. | |
| CR#3144 | GLFUG | n/a | QESTField, QESTLab | Sample Article: Sub-sampling separator changed to '-' | When Sample Article IDs are generated after sub-sampling or merging a Sample Article (ID 40000), the separator '-' will be used. |
QESTLab 4.0.1300 RC
Compatible with QESTField/QESTNET 4.0.19 (QESTNET.Upgrade 1.0.208) and Construction Hive 1.100.16136.0
| Bug/CR ID | Customer Code | Customer Reference | Product(s) Modified | Name | Release Notes |
|---|---|---|---|---|---|
| CR#3221 | GLFUG | n/a | QESTLab | Services cannot be added to Projects that have been imported from the Data Backbone | A change has been made to allow test types to be added to projects, which have been imported from the data backbone, when opened in the Project Management interface. Projects imported from the data backbone can now be synced to Construction Hive. |
QEST Platform 4.0.3006
Compatible Construction Hive Version: v1.700.18232
More information on QPM-1728 (Shipment receipt using sample barcodes) is available as a separate PDF file, please contact Spectra QEST for a copy.
| Issue ID | Release Notes |
|---|---|
| QPM-1442 | The type mismatch error when users search audit trails on the "Search" tab has been fixed.
Also, audit fields will be extracted if a result field is defined as a custom function. |
| QPM-1663 | The abbreviation displayed in the LTP for calcium carbonate content tests has been corrected - CaC03 -> CaCO3 |
| QPM-1669 | The standard workflow header containing project and sample details is now displayed in QESTNET for the following test methods:
|
| QPM-1677 | QLCDataFilters Error 13 and 91 caused by adding Items to the Report Comments List have been addressed. |
| QPM-1681 | The Assessment Types selection now updates when changing between projects. |
| QPM-1682 | The following changes has been implemented for Pocket Penetrometer, Torvane, Laboratory Vane, Fallcone workflows:
|
| QPM-1684 | A "Test No" field has been added to liquid and plastic limit specimens for the following test methods:
This field is used to maintain a consistent order of specimens in QESTNET. |
| QPM-1696 | Liquidity index for multi point and single point casagrande ASTM D4318 test is now reported from FILMS. |
| QPM-1723 | Nine additional data sequences are now reported from FILMS:
|
| QPM-1724 | Particle Density will now be exported for UU, UCS, CD and CU Triaxial tests. |
| QPM-1727 | Barcodes will now be imported from samples in fugris when importing an ltp using Construction Hive |
| QPM-1728 | The shipment receipt screen has been enhanced to allow samples to be marked as received by scanning the sample's barcode. |
| QPM-1798 | Liquidity index is no longer divided by 100 for export to the data backbone. It is stored as a ratio in the QESTLab database, so does not need to be converted during the export |