Jump to content

QESTonline:Test Method AS1289.5.3.1: Difference between revisions

From QESTonline
No edit summary
No edit summary
 
Line 42: Line 42:
| Date created
| Date created
| June 2006
| June 2006
|-
| Date last modified
| 14/09/2006
|-
|-
| Warning messages
| Warning messages

Latest revision as of 02:49, 14 September 2006

Prev || Next || Main Page

Test Description

The test method AS1289.5.3.1 Field Density Sand Replacement is an alternative method to the nuclear field density test. It dertermines the field density of soils by sand replacement method using sand-cone apparatus

Summary

Description Comments
Full Screen Yes
Reduced Screen Yes
Equipement Balance, Sieve
Import data Moisture content from sibbling test when available
Reporting Yes
Chart No
Bulk Entry Yes
External use Compaction test, HILF Test report, DDR Test report
Icon
Date created June 2006
Warning messages 0


Screen shots

First Strip *

Second Strip *

Third Strip *

  • Note that the values entered give an idea of the range expected but may not be practical/realistic.

How to complete the test

Name Expected Required Used for calculation
Strip 1
Equipment - Sieve / Balance Select any equipment from combo boxes No No
Description - Depth of the layer tested value > 0 No No
Description - Soil description Text No No
Strip 2
Pouring Apparatus - Test 1, 2 and 3 must be completed value > 0 Yes Yes
Pouring Density - Test 1, 2 and 3 must be completed value > 0 Yes Yes
Strip 3
Surface correction value > 0 Yes Yes
Hole Excavation - all fields value > 0 Yes Yes
Hole Excavation - Mass of sand required to fill the excavated hole result <> 100 Yes Yes

Interaction with other screens

Interdependencies

1st) The “Field Density Sand Replacement test” imports the moisture content from any “Moisture Content test”
2nd) “Compaction test” imports the maximum dry density from either an “Maximum Dry Density test – MDD” or an “Hilf Test”
3rd) “Compaction test” imports the field density from the “Field Density Sand Replacement test”
4th) The connections between those tests are limited to the ones aforementioned. Thus, there is no direct interaction between the “MDD test” and the “Field Density Sand Replacement test” neither between the “Hilf Test” and the “Field Density Sand Replacement test”
5th) Finally note that the “Field Density Sand Replacement test” can be replaced by a “Nuclear Field Density test” or the “Nuclear Gauge test” as they all determine the field density.

Fields imported by other tests:

Field names Destination
Wet density Hilf ratio and converted wet density - standard AS1289.5.7.1
Dry density
Depth of layer tested
Depth of the hole
Wet density Dry Density ratio ???
Dry density
Depth of layer tested
Depth of the hole

How to complete related tests

Guideline
Complete moisture content
Complete sand replacement
Complete Hilf A
...
...
...
Add a report
See the report

Prev || Next || Main Page

[[Category:Help|Template:Test Method]]