Jump to content

Template:QEST Platform 4.0.3006 Release Notes: Difference between revisions

From QESTonline
mNo edit summary
mNo edit summary
Line 1: Line 1:
QEST Platform 4.0.3006
== QEST Platform 4.0.3006 ==


More information on QPM-1728 (Shipment receipt using sample barcodes) is available as a separate PDF file, please contact Spectra QEST for a copy.
More information on QPM-1728 (Shipment receipt using sample barcodes) is available as a separate PDF file, please contact Spectra QEST for a copy.

Revision as of 04:27, 26 March 2018

QEST Platform 4.0.3006

More information on QPM-1728 (Shipment receipt using sample barcodes) is available as a separate PDF file, please contact Spectra QEST for a copy.

Issue ID Release Notes
QPM-1442 The type mismatch error when users search audit trails on the "Search" tab has been fixed.

Also, audit fields will be extracted if a result field is defined as a custom function.

QPM-1663 The abbreviation displayed in the LTP for calcium carbonate content tests has been corrected - CaC03 -> CaCO3
QPM-1669 The standard workflow header containing project and sample details is now displayed in QESTNET for the following test methods:
  • Min/Max Dry Density [BS 1377-4: 1990]
  • Min/Max Dry Density [ASTM D 4253, D 4254]
  • Min/Max Dry Density [LT-028, LT-029]
QPM-1677 QLCDataFilters Error 13 and 91 caused by adding Items to the Report Comments List have been addressed.
QPM-1681 The Assessment Types selection now updates when changing between projects.
QPM-1682 The following changes has been implemented for Pocket Penetrometer, Torvane, Laboratory Vane, Fallcone workflows:
  • Warning messages will now be displayed when the readings are not consistent with the 'reading out of range' checkboxes.
  • Readings will be locked when the test is marked as 'reading out of range'.
  • No readings will be sent back to fdbb if the test is marked as 'reading out of range'.
QPM-1684 A "Test No" field has been added to liquid and plastic limit specimens for the following test methods:
  • Liquid Limit - Casagrande \[BS 1377-2: 1990 cl 4.5]
  • Liquid Limit - One Point Casagrande \[BS 1377-2: 1990 cl 4.6]
  • Liquid & Plastic Limit (Multi-point - Method A) \[ASTM D 4318]
  • Liquid & Plastic Limit (One-point - Method B) \[ASTM D 4318]

This field is used to maintain a consistent order of specimens in QESTNET.

QPM-1696 Liquidity index for multi point and single point casagrande ASTM D4318 test is now reported from FILMS.
QPM-1723 Nine additional data sequences are now reported from FILMS:
  • Membrane Collection,
  • Filter Paper Correction,
  • Minor Principle Effective Stress,
  • Major Principle Effective Stress,
  • Principle Effective Stress Ratio,
  • Isotopic Stress,
  • Deviator Stress,
  • Time,
  • Specimen CSA (Area)
QPM-1724 Particle Density will now be exported for UU, UCS, CD and CU Triaxial tests.
QPM-1727 Barcodes will now be imported from samples in fugris when importing an ltp using Construction Hive
QPM-1728 The shipment receipt screen has been enhanced to allow samples to be marked as received by scanning the sample's barcode.
QPM-1798 Liquidity index is no longer divided by 100 for export to the data backbone. It is stored as a ratio in the QESTLab database, so does not need to be converted during the export