Test Description

The test method AS1289.5.3.1 Field Density Sand Replacement is an alternative method to the nuclear field density test. It dertermines the field density of soils by sand replacement method using sand-cone apparatus

Summary

Description Comments
Full Screen Yes
Reduced Screen Yes
Equipement Balance, Sieve
Import data Moisture content from sibbling test when available
Reporting Yes
Chart No
Bulk Entry Yes
External use HILF Test report, DDR Test report
Icon
Date created June 2006
Warning messages 0


Screen shots

First Strip *

Second Strip *

Third Strip *

  • Note that the values entered give an idea of the range expected but may not be practical/realistic.

How to complete the test

Name Expected Required Used for calculation
Strip 1
Equipment - Sieve / Balance Select any equipment from combo boxes No No
Description - Depth of the layer tested value > 0 No No
Description - Soil description Text No No
Strip 2
Pouring Apparatus - Test 1, 2 and 3 must be completed value > 0 Yes Yes
Pouring Density - Test 1, 2 and 3 must be completed value > 0 Yes Yes
Strip 3
Surface correction value > 0 Yes Yes
Hole Excavation - all fields value > 0 Yes Yes
Hole Excavation - Mass of sand required to fill the excavated hole result <> 100 Yes Yes

Interaction with other screens

Interdependencies

Like "Nuclear Field Density" tests, the "Field Density Sand Replacement" test is often used in conjunction with:
- any "Moisture Content" test
AND
- a "Hilf ratio and converted wet density" test
OR
- a "Dry Density Ratio" test

Fields imported by other tests:

Field names Destination
Soil description Hilf ratio and converted wet density - standard AS1289.5.7.1
Wet density
Dry density
Depth of layer tested
Depth of the hole
Soil description Dry Density ratio ???
Wet density
Dry density
Depth of layer tested
Depth of the hole

How to complete related tests