Bug/CR ID Customer Code Customer Reference Product(s) Modified Name Release Notes
Bug#5760 AUCOF Cof16.125 QESTLab Hydrometer: Calculation corrections for AS/RMS tests The following changes have been made to test screens Grading - Hydrometer [AS 1289.3.6.3] (ID 11021) and Grading - Hydrometer [RMS T190] (ID 11022)

The Total Dry Mass of the hydrometer sub-sample will now be calculated according to formula 7(2) of the standard AS 1289.3.6.3 New fields have been added to the Pretreatment tab to determine Mass of Dispersing Agent (g) A bug which caused the field Mass Before Pretreatment (g) to become unlocked has been fixed. The value of Mass After Pretreatment (g) will be adjusted using the Mass of Dispersing Agent (g) rather than the value of Dispersant Correction Ca. Mass After Pretreatment (g) will no longer overwrite the dry mass of the sub-sample after a split at the 2.36mm sieve The hydrometer reading/depth calibration will now be interpolated using a line of best fit of all calibrated points, rather than the two neighbouring point, when determining the value of correction factor F1 Correction factor F2 will now be calculated rather than derived from a lookup table. This removes the restriction placed on the value of soil density. The calculation for Adj. Smaller than D (%) will now apply the soil density correction factor.

Additionally, a bug which caused the warning text to display incorrectly for some hydrometer tests has been fixed.

Bug#6689 AUGCC QESTLab CBR values are not updated correctly An issue where changing Seating Deflection or Seating Load would not update CBR values correctly has been fixed.
Bug#6827 AUPAR QESTLab CBR: Load Cell Reading Convertion For Q113 CBR test screens, users can now directly record the force readings from a load cell and QESTLab will converts the values into Newton based on the force unit set for the selected load cell equipment.



The following changes have been made as well: - Drop-down boxes and edit boxes are now aligned in Force Indicator frame. - A warning message will show up when users switching between different force indicators (proving ring and load cell) and any penetration results are entered.

Bug#6891 AUQMR QESTLab CBR: Negative correction Negative correction is no longer applied for CBR values on CBR test screens.
Bug#6994 INTERNAL QESTLab California Bearing Ratio - Import MDD result Pressing the Import button in the compaction section of the CBR screen now imports the MDD and OMC values from the specified sample instead of throwing a runtime error 91.