QESTLab 4.3.2775.35829, QESTField 4.3.10, QESTNET Database Upgrade 4.3.1314.35510

From QESTonline

QESTLab 4.3.2775.35829, QESTField 4.3.10, QESTNET.Upgrade 4.3.1314.35510

Bug/CR ID Customer Code Customer Reference Product(s) Modified Name Release Notes
Bug#5723 USAET QESTLab Concrete Remarks - Remark with trailing space displaying twice Remarks which include a trailing space will no longer be displayed twice on the Concrete Test Report.
Bug#5980 USAET QESTField, QESTLab Concrete Sample: TimeInTruck calculation The calculation for TimeInTruck field now only uses TimeBatched and TimePlaced and a new on-screen option is implemented on Concrete Sample screen, Bulk Entry and QESTField Concrete workflow to set TimePlaced as TimeSampled.
Bug#6783 USPSI QESTLab Roller Compacted Concrete Density Report - Material and Supplier do not wrap properly The values for the Material and Supplier columns, when they wrap across multiple lines, will now have sufficient height to display correctly.
Bug#6787 USPSI QESTLab Specific Gravity ASTM C 128 - Mass of Pycometer and Water calculation If there is no calibration values for the Pycnometer, the Mass of Pycnometer and Water will not be calculated and can be entered by the user.
Bug#6805 USPSI QESTLab Management Reports - Export to CSV A bug where headers had additional quotation marks added at the start and end has been corrected.


All values (headers and data) are wrapped in quotation marks in cases where the value contains double-quotes, a comma, or a newline character. Quotation marks within a value are doubled, as per RFC 4180.

Bug#6810 USPSI Other, QESTLab Sodium Sulfate Soundness [Tex-411-A] * reported as magnesium sulfate The label used on the agg/soil test report for the results only (110737) Sodium Sulfate Soundness [Tex-411-A]* test has been changed from Magnesium Soundness Loss (%) to Sodium Soundness Loss (%).
Bug#6826 USSME QESTLab Generic Equipment Calibration Worksheet - Data Validation Calibration values on a Generic Calibration worksheet are now validated to ensure that they are of the appropriate type. This is done based on the format assigned to the calibration field.

- Invalid values are highlighted in red, with a validation message displayed next to them.
- If any of the calibration values are invalid, the user will be unable to 'finish' the calibration.
- If any of the calibration values are invalid, the user will be unable to leave the screen ("Some information on the current screen is incorrect").

Bug#6833 USPSI QESTField QESTField: DbContext has been disposed An issue where an exception message, "The operation cannot be completed because DbContext has been disposed", showed up after any test is created for a new workorder has been fixed.
Bug#6836 INTERNAL QESTLab N/A N/A
Bug#6846 USPSI QESTLab Aggregate/Soil Test Report: Unable to load PSD Predominant Non Classified when reported values are overlapped in Other Test Results section An issue, where PSD Predominant Non Classified test report view could not be loaded because of overlapping results in the Other Test Results section of Aggregate/Soil Test Report, has been addressed. A new page which contains Other Test Results will be added if no sufficient space is available.