Jump to content

QESTField 4.1.14 Release Notes

From QESTonline

QESTField 4.1.14

Bug/CR ID Customer Code Customer Reference Product(s) Modified Name Release Notes
Bug#5359 INTERNAL QESTLab, QESTField Relative Compaction: Reduced proctor tests never allow field oversize adjustment when imported to ASTM or TxDOT screens Previously, if a reduced proctor test was imported to a Relative Compaction (ASTM) [ID 110201] or Relative Compaction (TxDOT) [ID 110202] test no field oversize adjustment could be made. To allow this, reduced proctor tests will now be assumed to have been performed using the Saturated Surface Dry method as long as "Oversize Specific Gravity" has a value set.
Bug#5360 USPSI QNET649 QESTField Sample Pickups: Error when adding ASTM C136/C117 workflow A bug which caused an error message to appear when adding the workflow "Sample Pickup - ASTM C136/C117 Sieve of Fine & Coarse Agg by Wash" has been fixed.
Bug#5364 INTERNAL QESTField, QESTLab Relative Compaction: QESTField copies Laboratory Oversize into Field Oversize A bug which caused QESTField to copy Laboratory Oversize (%) from the imported proctor into the Relative Compaction test's "Dry Oversize (%)" field has been fixed.



The following changes were also made to QESTField to make the Adjustment Maximum Dry Density calculation consistent with QESTLab:

  • If no field oversize correction is performed, the AMDD value will be taken from the imported proctor.
  • For AASHTO and ASTM test methods, no field oversize adjustment will be performed if Dry Oversize (%) is less than 5 (in accordance with standards ASTM D 4718 and AASHTO T 99).

QESTLab 4.1.2000 RC

Complete Release Notes available here: QESTLab 4.1.2000 RC, QESTField 4.1.14 (QESTNET.Upgrade 1.32) Release Notes